Eaton Moeller series xEffect - PXS24 Electronic Protection Module. Placeholder for PXS24 series with no electrical function
Product Name |
Eaton Moeller series xEffect - PXS24 current monitoring relay
|
Catalog Number |
PXS24ACC0000
|
EAN |
9010238011397
|
UPC |
786689167424
|
Product Length/Depth |
127 mm
|
Product Height |
93 mm
|
Product Width |
18 mm
|
Product Weight |
0.118 kg
|
Compliances |
RoHS conform
|
Certifications |
EN45545-2
IEC 61373 |
Model Code |
PXS24-PCH
|
Type |
Automation engineering 24V
|
Voltage type |
DC
|
Voltage rating |
24 VDC (15 VDC - 30 VDC)
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
15 V
|
Rated control supply voltage (Us) at DC - max |
30 V
|
Current measurement - min |
0 A
|
Current measurement - max |
0 A
|
Electric connection type |
Plug-in connection
|
Adjustable delay-on energization time - min |
0 s
|
Permitted delay-on energization time - max |
0 s
|
Adjustable off-delay time - min |
0 s
|
Permitted off-delay time - max |
0 s
|
Mounting method |
Snap-fit on DIN rail (EN 60715)
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
1
|
Busbar type |
LINE (+) and GND (-); max 60A in various lengths of up to 1m
|
Terminal capacity |
2.5 mm² (flexible with ferrules)
4 mm² (rigid) |
Ambient operating temperature details |
-30° C - 55° C
|
Permitted storage and transport temperature - min |
-40 °C
|
Permitted storage and transport temperature - max |
100 °C
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
Functions |
DC-voltage over current
|
Protection |
None
|
Text field type |
17.5 mm x 6 mm
|