Lae dokument alla () … 20

279411
Mudeli kood: M22-D4-S

Eaton Moeller® series M22 Position pushbutton, RMQ-Titan, Actuators non-flush, momentary, 4-fold, opposing pushbuttons not mechanically interlocked, Bezel: titanium

General specifications

Product Name
Eaton Moeller® series M22 4-way pushbutton
Catalog Number
279411
EAN
4015082794118
Product Length/Depth
55 mm
Product Height
32 mm
Product Width
55 mm
Product Weight
0.022 kg
Compliances
CE Marked
Certifications
UL 508
EN 60947-5
IEC 60947-5
CSA Std. C22.2 No. 94-91
CSA Std. C22.2 No. 14-05
VDE
UL File No.: E29184
CSA Class No.: 3211-03
CSA-C22.2 No. 14-05
CSA
UL
UL Category Control No.: NKCR
IEC/EN 60947-5
CE
CSA File No.: 012528
CSA-C22.2 No. 94-91
IEC/EN 60947
VDE 0660
DNV
GL
LR
Catalog Notes
4-fold
Model Code
M22-D4-S

Omadused ja funktsioonid

Bezel color
Chrome
Bezel material
Plastic
Design
Non-Flush
Classical
Fitted with:
Front ring
Functions
Opposing pushbuttons not mechanically interlocked
Inscription
No inscription

Üldist

Degree of protection
NEMA 3R
NEMA 12
NEMA 4X
NEMA 13
IP66
Degree of protection (front side)
NEMA 4X
IP66
Lifespan, mechanical
200,000 Operations
Opening diameter
22.5 mm
Operating frequency
3600 Operations/h
Product category
RMQ-Titan
Product category
RMQ-Titan
Size
Front dimensions: 55 x 55 mm
Type
Pushbutton

Keskkonnatingimused, mehaanilised

Mounting position
As required
Shock resistance
Mechanical, According to IEC/EN 60068-2-27
30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms

Ilmastikutingimused

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Kommunikatsioon

Connection to SmartWire-DT
Yes
With SWD-RMQ connections

Aktuaator

Actuating force
5 N
Actuator color
Black
Actuator function
Spring-return
Momentary

Kontaktid

Force for positive opening - min
0 N

Vastavusavaldus

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
Not applicable.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Ekspordi toote tehnilised andmed