Eaton Moeller® series LS4 Actuator, form XB LS4-XB
Product Name |
Eaton Moeller® series LS4 Actuator
|
Catalog Number |
106860
|
EAN |
4015081066209
|
Product Length/Depth |
10 mm
|
Product Height |
40 mm
|
Product Width |
53 mm
|
Product Weight |
0.022 kg
|
Certifications |
IEC/EN 60947
|
Catalog Notes |
With the actuator inserted, the N/O contact is open and the NC contact is closed.
|
Model Code |
LS4-XB
|
Model |
Standard actuator
|
Operating frequency |
1800 Operations/h
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Repetition accuracy |
0.02 mm (Contacts/switching capacity)
|
Type |
|
Mounting position |
As required
|
Shock resistance |
25 g, Standard-action contact, Mechanical, Half-sinusoidal shock 20 ms
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Terminal capacity (flexible with ferrule) |
2 x (0.5 - 1.5) mm²
1 x (0.5 - 1.5) mm² |
Terminal capacity (solid) |
2 x (0.75 - 1.5) mm²
1 x (0.75 - 2.5) mm² |
Rated insulation voltage (Ui) |
500 V
|
Rated operational current (Ie) |
10 A at AC-15, 24 V
3 A at 24 V 0.8 A at 110 V 0.3 A at 220 V 6 A at AC-15, 220 V 230 V 240 V 4 A at AC-15, 380 V 400 V 415 V |
Short-circuit protection rating |
Max. 6 A gG/gL, Fuse, Contacts
|
Supply frequency |
Max. 400 Hz, Contacts
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
Not applicable.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|