Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 7.5 kW, 1 NC, 230 V 50/60 Hz, AC operation, Spring-loaded terminals DILMC15-01(230V50/60HZ)
| Product Name |
Eaton Moeller® series DILM contactor
|
| Catalog Number |
293954
|
| Model Code |
DILMC15-01(230V50/60HZ)
|
| EAN |
4015082939540
|
| Product Length/Depth |
75 mm
|
| Product Height |
68 mm
|
| Product Width |
45 mm
|
| Product Weight |
0.228 kg
|
| Certifications |
UL Category Control No.: NLDX
IEC/EN 60947-4-1 UL VDE 0660 CE IEC/EN 60947 CSA CSA-C22.2 No. 60947-4-1-14 UL File No.: E29096 CSA Class No.: 2411-03, 3211-04 CSA File No.: 012528 UL 60947-4-1 |
| Catalog Notes |
Contacts according to EN 50012
|
| Fitted with: |
Mirror contact
|
| Number of poles |
Three-pole
|
| Application |
Contactors for Motors
|
| Frame size |
FS1
|
| Lifespan, mechanical |
10,000,000 Operations (AC operated)
7,000,000 Operations (Coil 50/60 Hz) |
| Operating frequency |
5000 mechanical Operations/h (AC operated)
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Product category |
Contactors
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
| Rated impulse withstand voltage (Uimp) |
8000 V AC
|
| Resistance per pole |
2.5 mΩ
|
| Utilization category |
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-3: Normal AC induction motors: starting, switch off during running |
| Voltage type |
AC
|
| Shock resistance |
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature - max |
60 °C
|
| Ambient operating temperature (enclosed) - min |
25 °C
|
| Ambient operating temperature (enclosed) - max |
40 °C
|
| Ambient storage temperature - min |
40 °C
|
| Ambient storage temperature - max |
80 °C
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Emitted interference |
According to EN 60947-1
|
| Interference immunity |
According to EN 60947-1
|
| Terminal capacity (flexible with ferrule) |
1 x (0.75 - 1.5) mm²
2 x (0.75 - 1.5) mm² |
| Terminal capacity (flexible) |
1 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm² |
| Terminal capacity (solid) |
2 x (0.75 - 2.5) mm²
1 x (0.75 - 2.5) mm² |
| Terminal capacity (solid/stranded AWG) |
18 - 14
|
| Stripping length (main cable) |
10 mm
|
| Stripping length (control circuit cable) |
10 mm
|
| Screwdriver size |
3.5 mm, Spring-loaded terminals
|
| Rated breaking capacity at 220/230 V |
124 A
|
| Rated breaking capacity at 380/400 V |
124 A
|
| Rated breaking capacity at 500 V |
100 A
|
| Rated breaking capacity at 660/690 V |
70 A
|
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
22 A
|
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V |
15.5 A
|
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
15.5 A
|
| Rated operational current (Ie) at AC-3, 440 V |
15.5 A
|
| Rated operational current (Ie) at AC-3, 500 V |
12.5 A
|
| Rated operational current (Ie) at AC-3, 660 V, 690 V |
9 A
|
| Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V |
7 A
|
| Rated operational current (Ie) at AC-4, 400 V |
7 A
|
| Rated operational current (Ie) at AC-4, 500 V |
6 A
|
| Rated operational current (Ie) at AC-4, 660 V, 690 V |
5 A
|
| Rated operational current (Ie) at DC-1, 60 V |
20 A
|
| Rated operational current (Ie) at DC-1, 110 V |
20 A
|