Visual clogging indicators show when a filter element is clogged, and how clogged it is. They are meant for high-traffic areas where they can be observed on a regular basis.
The clogging indicators with designation AOR and AOC are visual pressure difference indicators with a reset function or control function.
Het maximale aantal artikels in de vergelijkingstool is vier.
Uw zoekopdracht "" kwam niet overeen met documenten of producten.
Gekopieerd naar klembord
Er zijn minimaal twee artikels nodig om de vergelijkingstool te kunnen gebruiken.
Sorry, we can't get that information right now.
| temperature ranges | |
| - operating temperature: | + 14°F to +176° F (for a short time +212°F) |
| - resistant to compression: | -22°F to +212°F |
| - survival temperature: | -40°F to +212°F |
| max. operating pressure: | 6000 PSI (stainless steel), 3200 PSI (aluminium) |
| max. pressure difference: | 2320 PSI |
| reset condition: | < 60% Δp-nominal |
| control condition: | < 80% Δp-nominal |
| max. display error: | ± 10% |
| fatigue strength: | max. 1 Mio load cycles for aluminium |