Download documento () de 20
Fazemos o que é importante funcionar*

014709
Model code: K150/1/BR

Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure. Connection terminal, 250A, 1p, round/round

General specifications

Product Name
Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure
Catalog Number
014709
EAN
4015080147091
Product Length/Depth
105 mm
Product Height
115 mm
Product Width
37 mm
Product Weight
0.712 kg
Compliances
RoHS conform
Model Code
K150/1/BR

Delivery program

Type
  • Accessory panel building
  • General switchboard accessory
Accessory/spare part type
Terminations
Terminals, 160 – 1000 A
Nominal current
250 A
Number of poles
Single-pole

Technical Data - Electrical

Rated insulation voltage (Ui)
1000 VAC
Rated operation current (Ie)
250 A

Technical Data - Mechanical

Mounting method
Screw
Number of connections (10 mm squared)
0
Number of connections (16 mm squared)
0
Number of connections (25 mm squared)
0
Number of connections (250 kcmil)
0
Number of connections (Less Than 6 mm squared)
0
Number of connections (Less Than AWG 6)
0
Number of connections (Greater Than 25 mm squared)
2
Number of connections (Greater Than 250 kcmil)
0
Number of connections (AWG 2)
0
Number of connections (AWG 4)
0
Number of connections (AWG 4/0)
0
Number of connections (AWG 6)
0
Number of connections (total)
2
Number of inputs
2
Number of outputs
2
Terminal capacity (aluminum cable)
35 mm² - 50 mm² (2x)
50 mm² - 120 mm² (1x)
Terminal capacity (copper/aluminum cable)
16 mm² - 70 mm² (2x)
35 mm² - 150 mm² (1x)
Conductor cross section, input - min
16 mm²
Conductor cross section, input - max
150 mm²
Conductor cross section, input AWG - min
6 mm²
Conductor cross section, input AWG - max
300 mm²
Conductor cross section, output - min
16 mm²
Conductor cross section, output - max
150 mm²
Conductor cross section, output AWG - min
6 mm²
Conductor cross section, output AWG - max
300 mm²

Additional information

Features
Contact safe
Special features
  • Conversion kits for strip terminal in cable connection available separately
  • Terminal covers available separately
  • Including labels for terminal marking U, V, W - X, Y, Z - L1, L2, L3 - T1, T2, T3 - PE, N, PEN, protective earth (ground) symbol
  • Relationship of rated operational current →terminal capacity to IEC/EN 60439, VDE 0660 Part 500 or EN 50021
  • Outer terminal for round or sectoral conductor, other side for Cu strip
Suitable for
Useful for stranded conductors
Used with
General switchboard accessory
Accessory panel building

Exportar as especificações do produto