A foto é representativa
Download
Eaton Moeller series NZM Undervoltage release for NZM2/3, configurable relays, 2NO, 208-240AC, Push-in terminals
| Product Name |
Eaton Moeller series NZM Undervoltage release
|
| Catalog Number |
189727
|
| EAN |
4015081877225
|
| Product Length/Depth |
115 mm
|
| Product Height |
65 mm
|
| Product Width |
75 mm
|
| Product Weight |
0.08 kg
|
| Compliances |
UL/CSA
IEC RoHS conform |
| Certifications |
CSA (Class No. 1437-01)
IEC60947 UL489 UL (File No. E140305) CSA (File No. 22086) UL listed UL (Category Control Number DIHS) CSA certified CE marking CSA-C22.2 No. 5-09 |
| Model Code |
NZM2/3-XU2A208-240AC
|
| Voltage type |
AC
|
| Rated insulation voltage (Ui) |
250 V
|
| Rated impulse withstand voltage (Uimp) |
4 kV AC
|
| Rated control voltage (relay contacts) |
240 V AC
24 V AC 24 V DC 208 V AC |
| Rated control supply voltage (Us) at AC, 50 Hz - min |
208 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
208 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
| Voltage tolerance - min |
0.85
|
| Voltage tolerance - max |
1.1
|
| Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
| Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
| Rated operational current |
1 A (110 V AC-1, relay contacts)
1 A (230 V AC-1, relay contacts) 1 A (24 V AC-1, relay contacts) 1 A (24 V DC-1, relay contacts) |
| Power consumption |
0.8 W (sealing DC)
1.5 VA (sealing AC) |
| Pick-up power consumption at AC (undervoltage release) |
1.5 VA
|
| Pick-up power consumption at DC (undervoltage release) |
0.8 W
|
| Switching capacity (reference value) - min |
0.1 mA / 0.1 VDC
|
| Reaction time |
19 ms
|
| Minimum command time - min |
10 ms
|
| Minimum command time - max |
15 ms
|
| Electric connection type |
Spring clamp connection
|
| Overvoltage category |
II
|
| Pollution degree |
2
|
| Rated impulse withstand voltage (Uimp) |
4 kV AC
|
| Rated control voltage (relay contacts) |
240 V AC
24 V AC 24 V DC 208 V AC |
| Rated control supply voltage (Us) at AC, 50 Hz - min |
208 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
208 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
| Voltage tolerance - min |
0.85
|
| Voltage tolerance - max |
1.1
|
| Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
| Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
| Rated operational current |
1 A (110 V AC-1, relay contacts)
1 A (230 V AC-1, relay contacts) 1 A (24 V AC-1, relay contacts) 1 A (24 V DC-1, relay contacts) |
| Power consumption |
0.8 W (sealing DC)
1.5 VA (sealing AC) |
| Pick-up power consumption at AC (undervoltage release) |
1.5 VA
|
| Pick-up power consumption at DC (undervoltage release) |
0.8 W
|
| Switching capacity (reference value) - min |
0.1 mA / 0.1 VDC
|
| Reaction time |
19 ms
|
| Minimum command time - min |
10 ms
|
| Minimum command time - max |
15 ms
|
| Electric connection type |
Spring clamp connection
|
| Overvoltage category |
II
|
| Pollution degree |
2
|
| Number of contacts (change-over contacts) |
0
|
| Number of contacts (normally closed contacts) |
0
|
| Number of contacts (normally open contacts) |
2
|
| Number of relays |
2
|
| Connection type |
With push in terminal
|
| Strip length |
8 mm (relay contact connection)
|