Download documento () de 20

269342
Model code: NZMN3-SE350-CNA

Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 350A, NZMN3-SE350-CNA

General specifications

Product Name
Eaton Moeller series NZM molded case circuit breaker electronic
Catalog Number
269342
EAN
4015082693428
Product Length/Depth
166 mm
Product Height
297 mm
Product Width
140 mm
Product Weight
6.34 kg
Compliances
RoHS conform
Certifications
IEC 60947-2
UL/CSA
UL (Category Control Number DKPU2)
IEC
UL 489
CSA-C22.2 No. 5-09
CSA certified
IEC/EN 60947
CE marking
UL listed
UL (File No. E31593)
Specially designed for North America
CSA (File No. 22086)
CSA (Class No. 1432-01)
Model Code
NZMN3-SE350-CNA

Dados técnicos - elétricos

Voltage rating
690 V - 690 V
Rated operating voltage Ue (UL) - max
600 V
Rated insulation voltage (Ui)
1000 V
Rated impulse withstand voltage (Uimp) at auxiliary contacts
6000 V
Rated impulse withstand voltage (Uimp) at main contacts
8000 V
Rated operational current
350 A (690 V AC-1, making and breaking capacity)
630 A (400 V AC-1, making and breaking capacity)
350 A (660-690 V AC-3, making and breaking capacity)
500 A (415 V AC-1, making and breaking capacity)
Rated short-time withstand current (t = 0.3 s)
3.3 kA
Rated short-time withstand current (t = 1 s)
3.3 kA
Amperage Rating
350 A
Instantaneous current setting (Ii) - min
700 A
Instantaneous current setting (Ii) - max
4900 A
Short-circuit release non-delayed setting - min
700 A
Short-circuit release non-delayed setting - max
4900 A
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz
85 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz
35 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz
35 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz
13 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz
5 kA
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz
187 kA
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz
105 kA
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz
74 kA
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz
53 kA
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
40 kA
Rated operating power at AC-3, 230 V
110 kW
Rated operating power at AC-3, 400 V
200 kW
Short-circuit total breaktime
< 10 ms
Electrical connection type of main circuit
Screw connection
Isolation
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts)
Number of operations per hour - max
60
Handle type
Rocker lever
Utilization category
A (IEC/EN 60947-2)
Overvoltage category
III
Pollution degree
3
Lifespan, electrical
5000 operations at 400 V AC-1
3000 operations at 690 V AC-1
2000 operations at 415 V AC-3
2000 operations at 690 V AC-3
2000 operations at 400 V AC-3
Direction of incoming supply
As required

Dados técnicos - comunicação

Rated impulse withstand voltage (Uimp) at auxiliary contacts
6000 V
Rated impulse withstand voltage (Uimp) at main contacts
8000 V
Rated operational current
350 A (690 V AC-1, making and breaking capacity)
630 A (400 V AC-1, making and breaking capacity)
350 A (660-690 V AC-3, making and breaking capacity)
500 A (415 V AC-1, making and breaking capacity)
Rated short-time withstand current (t = 0.3 s)
3.3 kA
Rated short-time withstand current (t = 1 s)
3.3 kA
Amperage Rating
350 A
Instantaneous current setting (Ii) - min
700 A
Instantaneous current setting (Ii) - max
4900 A
Short-circuit release non-delayed setting - min
700 A
Short-circuit release non-delayed setting - max
4900 A
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz
85 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz
35 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz
35 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz
13 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz
5 kA
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz
187 kA
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz
105 kA
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz
74 kA
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz
53 kA
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
40 kA
Rated operating power at AC-3, 230 V
110 kW
Rated operating power at AC-3, 400 V
200 kW
Short-circuit total breaktime
< 10 ms
Electrical connection type of main circuit
Screw connection
Isolation
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts)
Number of operations per hour - max
60
Handle type
Rocker lever
Utilization category
A (IEC/EN 60947-2)
Overvoltage category
III
Pollution degree
3
Lifespan, electrical
5000 operations at 400 V AC-1
3000 operations at 690 V AC-1
2000 operations at 415 V AC-3
2000 operations at 690 V AC-3
2000 operations at 400 V AC-3
Direction of incoming supply
As required

Dados técnicos - mecânicos

Mounting Method
Built-in device fixed built-in technique
Fixed
Degree of protection
IP20 (basic degree of protection, in the operating controls area)
IP20
Degree of protection (IP), front side
IP40 (with insulating surround)
IP66 (with door coupling rotary handle)
Degree of protection (terminations)
IP00 (terminations, phase isolator and strip terminal)
IP10 (tunnel terminal)
Protection against direct contact
Finger and back-of-hand proof to VDE 0106 part 100
Shock resistance
20 g (half-sinusoidal shock 20 ms)
Switch off technique
Electronic
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Lifespan, mechanical
15000 operations

Exportar as especificações do produto

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Autenticar produto

Introduza o seu número de série de 16–17 dígitos
O número de série que introduziu não deve conter caracteres especiais. O número de série que introduziu está incorreto; deve ter 16 ou 17 dígitos. O número de série que introduziu não foi encontrado. Tente novamente ou comunicar este problema para obter assistência adicional. O número de série que introduziu não corresponde ao produto. Verifique o número de série do seu produto e tente novamente. Clique aqui para navegar até à página do produto correspondente ao número de série que introduziu O número de série é considerado SUSPEITO pela Eaton, tente novamente ou comunicar este problema para obter assistência adicional.
Número de série
Reset O número de série é considerado SUSPEITO pela Eaton, tente novamente ou comunicar este problema para obter assistência adicional. O número de série não é reconhecido pela Eaton e é inválido. Utilize este formulário para comunicar este problema para obter assistência adicional.
Introduza o código de autenticação de 6 dígitos
O produto que introduziu é suspeito! Tente novamente ou comunicar este problema para obter assistência adicional. O código de autenticação que introduziu não corresponde aos nossos registos para este número de série. Tente novamente ou comunicar este problema para obter assistência adicional. Código de autenticação inválido. O comprimento deve ser de 6 caracteres comunicar este problema para obter assistência adicional. O código de autenticação é obrigatório comunicar este problema para obter assistência adicional.
Conclua o desafio Captcha antes de autenticar.
Contacte-nos para comunicar problema
x
Comunicar um problema
Introduza o seu nome completo.
x
Obrigado, o seu problema foi submetido. A nossa equipa de produto entrará em contacto consigo em breve.
Nota: Se existirem ficheiro(s) em falta na pasta .zip transferida, significa que o tipo de ficheiro não é compatível com a transferência de vários ficheiros em simultâneo.