Reset

Eaton Moeller® series EASY Control relays easyE4 with display (expandable, Ethernet), 24 V DC, Inputs Digital: 8, of which can be used as analog: 4, screw terminal
Product Name |
Eaton Moeller® series EASY Control relay
|
Catalog Number |
197213
|
EAN |
4015081939466
|
Model Code |
EASY-E4-DC-12TC1
|
Product Length/Depth |
58 mm
|
Product Height |
90 mm
|
Product Width |
72 mm
|
Product Weight |
0.2 kg
|
Compliances |
Eaton supports the product until its end of life
|
Certifications |
CSA-C22.2 No. 61010
EN 61010 IEC/EN 61000-6-2 IEC 60068-2-27 IEC 60068-2-30 IEC/EN 61000-4-2 CULus per UL 61010 IEC 60068-2-6 IEC/EN 61000-6-3 IEC/EN 61131-2 EN 50178 UL Listed UL Category Control No.: NRAQ, NRAQ7 UL File No.: E205091 DNV GL CE UL hazardous location class I UL hazardous location division 2 UL hazardous location group A (acetylene) UL hazardous location group B (hydrogen) UL hazardous location group C (ethylene) UL hazardous location group D (propane) |
Catalog Notes |
Accuracy of the real-time clock depending on ambient air temperature - fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible
|
Features |
Parallel connection of transistor outputs with resistive load, inductive load with external suppressor circuit, combination within a group - Group 1: Q1 to Q4
Networkable (Ethernet) Expandable Display indication of 6 lines x 16 characters |
Fitted with: |
Keypad
Display Real time clock Timer |
Functions |
Thermal cutout
|
Indication |
LCD-display used as Output status indication of Transistor outputs
LCD-display used as status indication of Digital inputs 24 V DC |
Degree of protection |
IP20
|
Display temperature - min |
0 °C
|
Display temperature - max |
55 °C
|
Display type |
Monochrome
|
Duty factor |
100 % (Inductive load to EN 60947-5-1, With external suppressor circuit)
100 % (Inductive load to EN 60947-5-1, Without external suppressor circuit, T0.95 = 15 ms, R = 48 Ω, L = 0.24 H) 100 % (Inductive load to EN 60947-5-1, Without external suppressor circuit, DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H) |
Frequency counter |
Cable length: ≤ 20 m (screened, Digital inputs 24 V DC)
Number: 4 (I1, I2, I3, I4 - Digital inputs 24 V DC) Pulse pause ratio: 1:1 (Digital inputs 24 V DC) Pulse shape: Square (digital inputs 24 V DC) Counter frequency: 5 kHz (Digital inputs 24 V DC) |
Insulation resistance |
According to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
|
Mounting method |
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm) Front build in possible Wall mounting/direct mounting Rail mounting possible |
Operating frequency |
Dependent on the cycle time of the basic device
Dependent on the cycle- and transmission-time of the expansion devices Depending on the suppressor circuit (Inductive load to EN 60947-5-1, With external suppressor circuit, Max. switching frequency, max. duty factor) |
Overvoltage category |
III
|
Pollution degree |
2
|
Product category |
Control relays easyE4
|
Protocol |
TCP/IP
MODBUS |
Residual current |
0.1 mA (on signal "1" per channel)
|
Residual ripple |
5 % (transistor outputs)
≤ 5 % |
Resolution |
|
Software |
EASYSOFT-SWLIC/easySoft
|
Type |
easyE4 base device
|
Used with |
easyE4
|
Voltage type |
DC
|
Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
Mounting position |
Vertical
Horizontal |
Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts
|
Vibration resistance |
10 - 57 Hz, 0.15 mm constant amplitude
57 - 150 Hz, 2 g constant acceleration According to IEC/EN 60068-2-6 |
Air pressure |
795 - 1080 hPa (operation)
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
55 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
70 °C
|
Environmental conditions |
Condensation: prevent with appropriate measures
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Relative humidity |
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)
|
Air discharge |
8 kV
|
Burst impulse |
According to IEC/EN 61000-4-4
2 kV, Supply cable 2 kV, Signal cable |
Contact discharge |
6 kV
|
Electromagnetic fields |
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.8 - 1.0 GHz (according to IEC EN 61000-4-3) 1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3) |
Immunity to line-conducted interference |
10 V (according to IEC/EN 61000-4-6)
|
Radio interference class |
Class B (EN 61000-6-3)
|
Surge rating |
0.5 kV, Supply cables, symmetrical, power pulses (Surge), EMC
According to IEC/EN 61000-4-5, power pulses (Surge), EMC 1 kV, Supply cables, asymmetrical, power pulses (Surge), EMC |
Voltage dips |
20 ms
≤ 10 ms, Bridging voltage dips |
Terminal capacity |
0.2 - 4 mm² (AWG 22 - 12), solid
0.2 - 2.5 mm² (22 - 12 AWG), flexible with ferrule |
Screwdriver size |
3.5 x 0.8 mm, Terminal screw
|
Tightening torque |
0.6 Nm, Screw terminals
|
Conventional thermal current Ith of auxiliary contacts (1-pole, open) |
0.5 A
|
Heat dissipation |
3.4 W (at 24 V DC)
|
Inrush current |
12.5 A (for 6 ms)
|
Power consumption |
2 W
|
Power loss |
2 W
|
Rated operational voltage |
24 V DC (-15 %/+ 20 % - power supply)
24 V DC (transistor outputs) 20.4 - 28.8 V DC (Transistor outputs) 24 V DC (digital inputs) 20.4 - 28.8 V DC |
Supply current |
24/44 mA, Normally⁄max., On 1 signal, Transistor outputs
18/32 mA, Normally⁄max., On 0 signal, Transistor outputs |
Supply voltage at AC, 50 Hz - min |
0 VAC
|
Supply voltage at AC, 50 Hz - max |
0 VAC
|
Supply voltage at DC - min |
20.4 VDC
|
Supply voltage at DC - max |
28.8 VDC
|
Short-circuit current |
6.8 A, Transistor outputs
|
Short-circuit protection |
≥ 1A (T), Fuse, Power supply
Yes, electronic (Q1 - Q4), Transistor outputs |
Short-circuit tripping current |
0.7 ≤ Ie ≤ 1.7 per output, For Ra ≤ 10 mΩ, Depending on number of active channels and their load, Transistor outputs
|
Connection type |
Screw terminal
Ethernet: RJ45 plug, 8-pole |
Data transfer rate |
10/100 MBit/s
|
Cable length |
≤ 30 m, screened, Analog inputs
100 m, unscreened, Digital inputs 24 V DC |
Cable type |
CAT5
|
Accuracy |
± 2 %, (I7, I8) ± 0.12 V, of actual value, within a single device (Analog Inputs)
± 3 %, of actual value, two easy devices (Analog Inputs) ± 2 s/day, Real-time clock to inputs (± 0.2 h⁄Year) ± 1 %, Repetition accuracy of timing relays (of values) |
Conversions |
Each CPU cycle, Analog inputs
|
Delay time |
0.015 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF
20 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 1 to 0, Debounce ON 0.015 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF 20 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 0 to 1, Debounce ON |
Incremental counter |
Pulse pause ratio: 1:1
Pulse shape: Square Value range: -2147483648 to +2147483647 Number of counter inputs: 2 (I1 + I2, I3 + I4) Signal offset: 90° Counter frequency: ≤ 5 kHz |
Incremental encoder |
Cable length: ≤ 20 m (screened)
|
Input |
Voltage (DC)
|
Input current |
1 mA (Analog inputs)
3.3 mA (I1 - I4, at 24 V DC, at signal 1) 2.2 mA (I5 - I8, at 24 V DC, at signal 1) 80 mA |
Input impedance |
13.3 kΩ
|
Input voltage |
Status 0: ≤ 15 V DC (I1 - I4, Digital inputs, 24 V DC)
Status 0: ≤ 8 V DC (I5 - I8, Digital inputs, 24 V DC) Status 1: ≥ 15 V DC (I1 - I4, Digital inputs, 24 V DC) Signal 0: ≤ 5 V DC (I1 - I8, Digital inputs, 24 V DC) |
Lamp load |
Max. 3 W (without Rv per channel)
|
Number of inputs (analog) |
0
4 |
Number of inputs (digital) |
8
|
Number of outputs (analog) |
0
|
Number of outputs (digital) |
4
|
Output |
Parallel connection of max. 4 Transistor outputs
2 A, Max. total current, Outputs 4 Transistor Outputs Voltage Current |
Output voltage |
U = Uₑ - 1 V (signal 1 at Iₑ = 0.5 A, transistor outputs)
Max. 2.5 V (at status 0 per channel, transistor outputs) |
Rapid counter inputs |
1:1 (Pulse pause ratio)
10 kHz, Counter frequency ≤ 20 m (cable length, screened) -2147483648 - 2147483647 (value range) Square (pulse shape) Number: 4 (I1, I2, I3, I4 - Digital inputs 24 V DC) |
Signal range |
0 - 10 V DC, Analog inputs
|
Utilization factor |
0.25 (Inductive load to EN 60947-5-1, Without external suppressor circuit, DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H)
0.25 (Inductive load to EN 60947-5-1, Without external suppressor circuit, T0.95 = 15 ms, R = 48 Ω, L = 0.24 H) 1 (Inductive load to EN 60947-5-1, With external suppressor circuit) |
Explosion safety category for gas |
None
|
Potential isolation |
Between Transistor outputs and Ethernet: yes
Between Digital inputs 24 V DC and Ethernet: yes Between Transistor outputs and control buttons: yes Between Transistor outputs and Power supply: yes Between Analog inputs and Outputs: yes Between Transistor outputs and expansion devices: yes Between Digital inputs 24 V DC and expansion devices: yes Between Analog inputs and expansion devices: yes Between Digital inputs 24 V DC: no Between Transistor outputs and Inputs: yes Between Transistor outputs: no Between Digital inputs 24 V DC and Power supply: no Between Analog inputs: no Between Analog inputs and Memory card: no Between Transistor outputs and Memory card: yes Between Digital inputs 24 V DC and Outputs: yes Between Analog inputs and Ethernet: yes Between Digital inputs 24 V DC and Memory card: no Between Analog inputs and Power supply: no |
Protection against polarity reversal |
For transistor outputs (Caution: A short circuit will result if 0 V/earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles)
Yes, for supply voltage (Siemens MPI optional) |
Explosion safety category for dust |
None
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
2 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|