10-30 kVA
208/220/400/480/600 VAC three phase
50/60 Hz
Double conversion
Tower
GENERAL |
||
DIAGNOSTICS |
Full system self-test at startup |
|
UPS BYPASS |
Automatic on overload or UPS failure |
|
PARALLEL FOR REDUNDANCY |
Yes, using Powerware Hot Sync technology and capacity |
|
DIMENSIONS AND WEIGHTS |
See product brochure |
|
OVERLOAD (NORMAL OPERATION) |
150% for 5 sec / 125% for 1 min (online), 110% for 10 min |
|
WARRANTY | 1 year | |
ELECTRICAL INPUT |
||
NOMINAL INPUT VOLTAGE |
9355 (10 - 15 kVA): 208V/120V or 220V/127V three-phase 400V models also available |
9355 (20 - 30 kVA): 208V/120V, 220V/127V +10, -15% 480V/277V, 600V (480+600 with transformer) 400V models also available |
INPUT VOLTAGE RANGE |
-15%, +10% from nominal at 100% load without depleting battery |
|
OPERATING FREQUENCY |
50/60 Hz (45 to 65 Hz) |
|
INPUT POWER FACTOR |
9355 (10 - 15 kVA): >0.99 typical, >0.96 frequency converter |
9355 (20 - 30 kVA): 0.99 typical |
INPUT CURRENT DISTORTION |
5% THD |
|
ELECTRICAL OUTPUT |
||
NOMINAL OUTPUT VOLTAGE |
9355 (10 - 15 kVA): 208/120, 220/127 Vac |
9355 (20 - 30 kVA): 208/120, 220/120 Vac |
OUTPUT VOLTAGE REGULATION |
9355 (10 - 15 kVA): ±1% static; ±5% dynamic at 100% resistive load change, <1 ms response time |
9355 (20 - 30 kVA): ±1% static; ±4% dynamic with 100% step load recovery within 1 ms response time |
EFFICIENCY |
91%, typical |
|
HEAT DISSIPATION (BTU/HR) |
10 kVA models: 15 kVA models: 5,122 @ 208V and 220V input |
20 kVA models: 30 kVA models: |
BATTERY |
||
BATTERY TYPE |
9 Ah, sealed, lead-acid, maintenance-free |
|
BATTERY RUNTIME |
See product brochure |
|
BATTERY MANAGEMENT |
ABM technology |
|
BATTERY REPLACEMENT |
Field-replaceable |
|
CHARGER |
9355 (10 - 15 kVA): Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current) |
9355 (20 - 30 kVA): Default is 8A |
START-ON-BATTERY |
Allows start of UPS without utility input |
|
COMMUNICATIONS |
||
LCD DISPLAY |
Graphical LCD with blue backlight |
|
LEDS |
(4) LEDs for notice and alarm |
|
AUDIBLE ALARMS |
Yes |
|
COMMUNICATION PORTS |
(1) RS-232, (1) relay contact, (1) REPO, (2) environmental input |
|
COMMUNICATION SLOTS |
(2) X-Slot communication bays |
|
POWER MANAGEMENT SOFTWARE |
Bundled software suite CD |
|
ENVIRONMENTAL |
||
OPERATING TEMPERATURE |
50–104ºF (10–40ºC), 45ºC with 7.5% derating; Optimal battery performance: 77ºF (25ºC) |
|
STORAGE TEMPERATURE |
32–77ºF (0–25ºC); Recommended battery storage: 59–77ºF (15–25ºC) |
|
RELATIVE HUMIDITY |
9355 (10 - 15 kVA): 0–95%, non-condensing |
9355 (20 - 30 kVA): 5–95%, non-condensing |
AUDIBLE NOISE |
9355 (10 - 15 kVA): <56 dBA at 1 meter (noiseless room) typical |
9355 (20 - 30 kVA): <58 dBA at 1 meter depending on load |
ALTITUDE |
9355 (10 - 15 kVA): 9,843 ft. (3000m) without derating |
9355 (20 - 30 kVA): <3000m |
CERTIFICATIONS |
||
SAFETY CERTIFICATIONS |
IEC 62040-1:2008/A1:2013, UL 1778 |
|
EMC COMPLIANCE |
EN 50091-2 Class A |
|
QUALITY |
ISO 9001: 2008 and ISO 14001:2004 |
|
MARKINGS |
UL, cULus |
|
POWER DISTRIBUTION MODULE WITH MECHANICAL BYPASS SWITCH |
See product brochure |
|
OPTIONS |
See product brochure |
|
BUILT-IN CONNECTIVITY OPTIONS |
See product brochure |
Support from Eaton