Télécharger le document () de 20
Nous faisons fonctionner l’essentiel*

032720
BK25/3-PKZ0

Eaton Moeller® series PKZ Extension terminal, 3p, 25mm² BK25/3-PKZ0

Spécifications générales

Product Name
Eaton Moeller® series PKZ Connection clamp
Catalog Number
032720
EAN
4015080327202
Product Length/Depth
25 mm
Product Height
38 mm
Product Width
45 mm
Product Weight
0.041 kg
Certifications
CSA Class No.: 3211-05
UL
CSA-C22.2 No. 14
CSA File No.: 165628
CSA
CE
UL 508
UL Category Control No.: NLRV
UL File No.: E36332
IEC/EN 60947-4-1

Caractéristiques du produit

Used with
PKZM0, PKE12, PKE32
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Pollution degree
3
Rated operational current for specified heat dissipation (In)
63 A
Width clamp
45 mm
Product category
Accessories
Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-25 °C
Conductor cross section - max
25 mm²
Equipment heat dissipation, current-dependent Pvid
5.4 W
Heat dissipation per pole, current-dependent Pvid
1.8 W
Rated operational current (Ie) - max
63 A
Overvoltage category
III
Suitable for
Other
Round conductor connection
Terminal capacity (stranded)
1 x (2.5 - 25) mm²
Rated operational current
63 A
Tightening torque
2.5 Nm
Terminal capacity (flexible with ferrule)
2.5 - 16 mm²

Exporter les caractéristiques du produit