Télécharger le document () de 20
Nous faisons fonctionner l’essentiel*

197212
EASY-E4-UC-12RCX1

Eaton Moeller® series EASY Control relays, easyE4 (expandable, Ethernet), 12/24 V DC, 24 V AC, Inputs Digital: 8, of which can be used as analog: 4, screw terminal

Spécifications générales

Product Name
Eaton Moeller® series EASY Control relay
Catalog Number
197212
EAN
4015081939473
Product Length/Depth
58 mm
Product Height
90 mm
Product Width
72 mm
Product Weight
0.25 kg
Compliances
Eaton supports the product until its end of life
Certifications
UL File No.: E205091
CE
UL hazardous location division 2
UL hazardous location class I
UL hazardous location group B (hydrogen)
UL hazardous location group C (ethylene)
UL hazardous location group A (acetylene)
UL hazardous location group D (propane)
cULus Ordinary Location
DNV
TAA00002HT
cULus Hazard Location
UL File No.: E523283
EN 61131-2
IEC 61131-2
EN IEC 61000-6-3
IEC 61000-6-3
EN IEC 61010-2-201
IEC 61010-2-201
UL 61010-1
UL 61010-2-201
CSA C22.2 No. 61010-1
CSA C22.2 No. 61010-2-201
UL 121201
CSA C22.2 No. 213
Catalog Notes
Accuracy of the real-time clock depending on ambient air temperature - fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible

Caractéristiques du produit

Used with
easyE4
Type
easyE4 base device
Features
Expandable
Networkable (Ethernet)
Air discharge
8 kV
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Cable type
Ethernet: CAT5
Fitted with:
Timer
Relay output
Real time clock
Pollution degree
2
Accuracy
± 2 s/day, Real-time clock to inputs (± 0.2 h⁄Year)
± 2 %, (I5, I6, I7, I8) ± 0.12 V, of actual value, within a single device (Analog Inputs)
± 1 %, Repetition accuracy of timing relays (of values)
± 3 %, of actual value, two easy devices (Analog Inputs)
Burst impulse
2 kV, I/O port
2 kV, Power supply port
1 kV, communication port
According to IEC/EN 61131-2
Utilization category
B 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes AC
R 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes DC
Rated impulse withstand voltage (Uimp)
Relay outputs: 6 kV (contact-coil)
Air pressure
795 - 1080 hPa (operation)
Category (EN 954-1)
None
Explosion safety category for dust
None
Environmental conditions
Condensation: prevent with appropriate measures
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Indication
Software used as status indication of digital I/Os
Input
Voltage (DC)
Explosion safety category for gas
None
Mounting method
Front build in possible
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Wall mounting/direct mounting
Rail mounting possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Screwdriver size
3.5 x 0.6 mm, Terminal screw
Voltage type
AC/DC
Mounting position
Horizontal
Vertical
Output
4 Relay Outputs
min. recommended load: 12 V AC/DC > 500 mA
Contact discharge
6 kV
Base type
Yes
Safety performance level (EN ISO 13849-1)
None
SIL (IEC 61508)
None
Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - max
70 °C
Ambient storage temperature - min
-40 °C
Equipment heat dissipation, current-dependent Pvid
1 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Number of HW-interfaces (industrial ethernet)
1
Number of HW-interfaces (other)
0
Number of HW-interfaces (parallel)
0
Number of HW-interfaces (RS-232)
0
Number of HW-interfaces (RS-422)
0
Number of HW-interfaces (RS-485)
0
Number of HW-interfaces (serial TTY)
0
Number of HW-interfaces (USB)
0
Number of HW-interfaces (wireless)
0
Overvoltage category
Power supply + Inputs + Extension: II
Relay outputs: III
Duty factor
100 %
Software
EASYSOFT-SWLIC/easySoft
Surge rating
1 kV, Line-to-Line, Power supply port
2 kV, Line-to-Earth, Power supply port
1 kV, Line-to-Line, Input port
2 kV, Line-to-Earth, Input port
1 kV, Line-to-Earth, communication port
According to IEC/EN 61131-2
Cable length
Digital inputs (DC): ≤ 100 m (unshielded)
Digital inputs (AC): ≤ 40 m (unshielded)
Analog inputs: ≤ 30 m (shielded)
Conversions
Each CPU cycle for Analog inputs
Electromagnetic fields
10 V/m at 0.08 - 1.0 GHz (according to IEC/EN 61131-2)
3 V/m at 1.0 - 6 GHz (according to IEC/EN 61131-2)
Protection against polarity reversal
Yes
Number of inputs (analog)
0
4
Connection type
Screw terminal
Ethernet: RJ45 plug, 8-pole
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Immunity to line-conducted interference
10 V (according to IEC/EN 61131-2)
Radio interference class
Class B (EN 61000-6-3)
Number of outputs (digital)
4
Data transfer rate
10/100 MBit/s
Relative humidity
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)
Degree of protection
IP20
Safe isolation
Relay outputs: 300 V AC, Between two contacts
Relay outputs: 300 V AC, Between coil and contact
Delay time
20 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 0 to 1, Debounce ON
20 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 1 to 0, Debounce ON
0.015 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF
0.015 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF
0.015 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF
0.015 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF
20 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 1 to 0, Debounce ON
20 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 0 to 1, Debounce ON
Protocol
Modbus TCP
Residual ripple
Power supply: ≤ 5 %
Rapid counter inputs
Value range: -2147483648 to +2147483647
Number of rapid counter inputs: 4 (I1, I2, I3, I4)
Cable length: ≤ 20 m (shielded)
Pulse pause ratio: 1:1
Pulse shape: Square
Counter frequency: ≤ 10 kHz
Supply frequency
50/60 Hz (± 5%)
Insulation resistance
According to EN IEC 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-213
Incremental counter
Number of counter inputs: 2 (I1 + I2, I3 + I4)
Signal offset: 90°
Pulse pause ratio: 1:1
Value range: -2147483648 to +2147483647
Pulse shape: Square
Counter frequency: ≤ 5 kHz
Cable length: ≤ 20 m (shielded)
Vibration resistance
8.4 - 150 Hz, 1 g constant acceleration
5 - 8.4 Hz, 3.5 mm constant amplitude
According to IEC/EN 61131-2
Input impedance
Analog: 13.3 kΩ
Input current
1.8 mA (I5 - I8, at 24 V DC,at signal 1)
3.3 mA (I1 - I4, at 24 V DC,at signal 1)
3.5 mA (I1 - I4, at 24 V AC,at signal 1)
1.8 mA (I5 - I8, at 24 V AC,at signal 1)
0.9 mA (I5 - I8, at 12 V DC,at signal 1)
1.75 mA (I1 - I4, at 12 V DC,at signal 1)
< 1 mA (Analog inputs)
Shock resistance
15 g, Mechanical, acc. to IEC/EN61131-2, Half-sinusoidal shock 11 ms, 18 Impacts
Frequency counter
Cable length: ≤ 20 m (shielded)
Counter frequency: ≤ 5 kHz
Number: 4 (I1, I2, I3, I4)
Pulse pause ratio: 1:1
Pulse shape: Square
Input frequency
50/60 Hz (Digital inputs at AC)
Input voltage
Condition 0: ≤ 5 V DC (Digital inputs, 12 V DC)
Condition 0: ≤ 5 V DC (Digital inputs, 24 V DC)
Condition 1: ≥ 15 V DC (Digital inputs, 24 V DC)
Condition 1: ≥ 8 V DC (Digital inputs, 12 V DC)
Condition 0: ≤ 5 V AC (Digital inputs, 24 V AC)
Condition 1: ≥ 15 V AC (Digital inputs, 24 V AC)
Rated breaking capacity
300000 Operations at AC-15, 250 V AC, 3 A (600 Ops./h)
200000 Operations at DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 Ops./h)
Lifespan, electrical
25,000 Operations (Filament bulb load at 500 W, 115/120 V AC)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device)
25,000 Operations (Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated)
25,000 Operations (Filament bulb load at 1000 W, 230/240 V AC)
LED indicator
Status indication of Power/RUN
Status indication of Ethernet
Signal range
0 - 10 V DC, Analog inputs
Lifespan, mechanical
10,000,000 Operations
Making/breaking capacity
3600/360 VA (AC, at B 300)
28/28 VA (DC, at R 300)
Parallel switching
Not permitted
Potential isolation
Power supply + Inputs + Extension interface against Outputs: yes
POW+Inputs+Extension interface vs. Ethernet+Functional Earth: yes
Outputs against Ethernet + Functional Earth: yes
Outputs against each other: yes
Number of inputs (digital)
4
8
Power loss
10 VA
Voltage dips
1 ms 12 V DC
10 ms at 24 V DC
20 ms at 24 V AC
Uninterrupted current
1 A DC, at R 300 (UL/CSA)
5 A AC, max. thermal continuous current cos ϕ = 1 at B 300 (UL/CSA)
8 A DC, at 24 V DC (UL/CSA)
10 A AC, at 240 V AC (UL/CSA)
Number of interfaces (PROFINET)
0
Number of outputs (analog)
0
Static heat dissipation, non-current-dependent Pvs
3 W
Supply voltage at AC, 50 Hz - max
26.4 VAC
Supply voltage at AC, 50 Hz - min
20.4 VAC
Supply voltage at AC, 60 Hz - max
26.4 VAC
Supply voltage at AC, 60 Hz - min
20.4 VAC
Supply voltage at DC - max
28.8 VDC
Supply voltage at DC - min
10.2 VDC
Switching current
8 A
Product category
Control relays easyE4
Protection
B16 circuit breaker or 8 A (T) fuse, Protection of an Output relay
Resolution
12 Bit (value 0 - 4095, Analog inputs)
Power consumption
3 W
Rated operational voltage
Power supply: 24 V DC (-15 %/+ 20 %)
Power supply: 24 V AC (-15 %/+ 10 %)
Power supply: 12 V DC (-15 %/+ 20 %)
Relay outputs: max. 300 V AC/DC
Inputs: shall be identical to the power supply voltage
Short-circuit protection
≥ 1A (T), Fuse, Power supply
Switching frequency
0.5 Hz, Inductive load, Relay outputs
2 Hz, Resistive load/lamp load, Relay outputs
10 Hz, Relay outputs
Terminal capacity
0.2 - 4 mm² (AWG 22 - 12), solid
0.2 - 2.5 mm², flexible with ferrule
0.2 - 2.5 mm², flexible without ferrule
Tightening torque
0.6 Nm, Screw terminals

Exporter les caractéristiques du produit

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Authentifier un produit

Saisissez votre numéro de série à 16 ou 17 chiffres
Le numéro de série saisi ne doit pas contenir de caractère spécial. Le numéro de série que vous avez saisi n’est pas correct, il doit comporter 16 ou 17 chiffres. Le numéro de série que vous avez saisi est introuvable. Veuillez essayer à nouveau ou signaler ce problème pour obtenir de l’aide. Le numéro de série que vous avez saisi ne correspond pas au produit. Vérifiez le numéro de série de votre produit et réessayez. Cliquer ici pour accéder à la page du produit du numéro de série que vous avez saisi Eaton a identifié le numéro de série comme étant suspect, veuillez réessayer à nouveau ou signaler ce problème pour obtenir de l’aide.
Numéro de série
Réinitialiser Eaton a identifié le numéro de série comme étant suspect, veuillez réessayer à nouveau ou signaler ce problème pour obtenir de l’aide. Le numéro de série n'est pas reconnu par Eaton et n'est pas valide. Veuillez utiliser ce formulaire pour signaler ce problème pour obtenir de l’aide.
Saisissez le code d’authentification à 6 chiffres
Le produit que vous avez saisi est suspect! Veuillez essayer à nouveau ou signaler ce problème pour obtenir de l’aide. Le code d’authentification que vous avez saisi ne correspond pas aux informations associées à ce numéro de série. Veuillez essayer à nouveau ou signaler ce problème pour obtenir de l’aide. Code d'authentification non valide. La longueur du code doit être de 6 caractères signaler ce problème pour obtenir de l’aide. Le code d’authentification est requis signaler ce problème pour obtenir de l’aide.
Veuillez compléter le test CAPTCHA avant de procéder à l’authentification.
Nous joindre pour signaler un problème
x
Signaler un problème
Veuillez saisir votre nom complet.
x
Merci, votre problème a été soumis, notre équipe produit communiquera avec vous prochainement.

Register Product

Please complete the form to register your product