Eaton xEffect SASY 60i Enclosures Switch- & Controlgear Enclosure. Fuse disconnector, 100A, 500V/100A, 690V/100A, NH00 size
| Product Name |
Eaton xEffect SASY 60i busbar system device NH
|
| Catalog Number |
139533
|
| EAN |
5019586152060
|
| Product Length/Depth |
125 mm
|
| Product Height |
160 mm
|
| Product Width |
90 mm
|
| Product Weight |
0.9 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC/EN 60947-3
|
| Model Code |
FCFSDNH000BBC60-3
|
| Frame |
NH00(0) (max. 21 mm)
|
| Frequency rating |
40 Hz - 60 Hz
|
| Pollution degree |
3
|
| Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
| Rated uninterrupted current (Iu) |
100 A
|
| Conditioned rated short-circuit current Iq |
50 kA
|
| Number of poles |
Three-pole
|
| Heat dissipation at Ith DC without NH-SE |
1.8 W
|
| Degree of protection |
IP10 (front cover open)
IP20 (operating state) |
| Rated short-time withstand current (Icw) |
50 kA
|
| Direction of incoming supply |
As required
|
| Distance between busbar centers |
60 mm
|
| Electrical connection type of main circuit |
Screw connection
|
| Actuator position |
Front side
|
| Actuator type |
Rocker lever
|
| Admissible heat dissipation (NH-SE) - max |
9 W
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-20 °C
|
| Fuse current rating at 500 V - max |
100 A
|
| Fuse current rating at 690 V - max |
100 A
|
| Heat dissipation at Ith AC without NH-SE |
2.7 W
|
| Mounting position |
Vertical or horizontal
|
| Suitable for |
Busbar mounting
For surface mounting on busbars Front mounting |
| Rated conditional short-circuit current (Iq) |
25 kA at DC (conditional)
50 kA 50 kA at AC (effective) |
| Functions |
Busbar fuse material
NH fuse switch-disconnector |
| Overvoltage category |
III
|
| Suitable for fuses |
NH00
|
| Cable entry type |
Other
|
| Frequency rating of contacts |
40 Hz - 60 Hz
|
| Rated operation current (Ie) |
100 A
|
| Voltage rating |
690 V AC, 440 V DC
|
| Type |
Compact system
|
| Special features |
Complete and functional fuse element consists of the basic device, fuse unit, fitted screw, screw cap
|
| Degree of protection (front side) |
IP20
|
| Lifespan, electrical |
300 operations
|
| Lifespan, mechanical |
1700 operations
|
| Terminal capacity (solid cable) |
1.5 mm² - 50 mm²
|
| Terminal capacity (stranded cable) |
16 mm² - 50 mm² at clamp-type terminal
|
| Rated breaking capacity |
80 A
100 A |
| Operating altitude without derating - max |
2000 mm
|
| Power rating at AC-23, 400 V |
40 kW
|
| Rated insulation voltage (Ui) |
750 V
|
| Rated making capacity at AC-22B |
100 A
|
| Rated making capacity at DC-21B |
80 A
|
| Rated operating voltage (Ue) at AC - max |
690 V
|
| Rated operational current (gL/gG) - max |
100 A
|