Vidensøgning
Download dokument () af 20
We make what matters work*

PXS24S02A002
PXS24S-e2/F/ORT

Eaton Moeller series xEffect - PXS24 Electronic Protection Module. Electronic overcurrent protection for 24V DC, fix 2A with tripped signal out-, control in-put, w/o supply terminals

Generelle specifikationer

Product Name
Eaton Moeller series xEffect - PXS24 current monitoring relay
Catalog Number
PXS24S02A002
EAN
9010238011229
UPC
786689167530
Product Length/Depth
127 mm
Product Height
93 mm
Product Width
18 mm
Product Weight
0.118 kg
Compliances
UL508
CE
RoHS conform
Certifications
EN45545-2
IEC 61373
Model Code
PXS24S-e2/F/ORT

Yderligere oplysninger

Features
Two-colored
OFF = Channel not in operation
Green = OK; Red = Triggered
Functions
DC-voltage over current
Protection
Electronic
Special features
  • Inductive loads: up to 13 A
  • On/Off/Reset
Text field type
17.5 mm x 6 mm

Leveringsprogram

Amperage Rating
2 A
Type
Automation engineering 24V

Designverifikation iht. IEC/EN 61439

10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.

Designverifikation i henhold til IEC/EN 61439 – tekniske data

Ambient operating temperature details
-30° C - 55° C
Equipment heat dissipation, current-dependent
0.4 W
Permitted storage and transport temperature - max
100 °C
Permitted storage and transport temperature - min
-40 °C
Rated operational current for specified heat dissipation (In)
2 A

Technical data - electrical

Capacitive load
Up to 20,000 µF
Current measurement - max
2.6 A
Current measurement - min
0 A
Electric connection type
Plug-in connection
Overload current and short-circuit current trip
Type 1.3 x IN with active current limitation
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at DC - max
30 V
Rated control supply voltage (Us) at DC - min
15 V
Rated operational current (Ie) fix
2 A
Trip time for electronic trip
470 ms
Voltage rating
24 VDC (15 VDC - 30 VDC)
Voltage type
DC

Technical data - mechanical

Busbar type
LINE (+) and GND (-); max 60A in various lengths of up to 1m
Mounting method
Snap-fit on DIN rail (EN 60715)
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
1
Output terminals
3x LOAD (+) and 3x GND (-)
Terminal capacity
2.5 mm² (flexible with ferrules)
4 mm² (rigid)
Terminal type
Push in terminals
Degree of protection
IP20
Number of channels
1

Eksportér produktspecifikation

eCAD model

Installationsvejledning

Bemærk: Hvis fil(er) mangler i .zip-download, understøttes filtypen ikke ved bulk download.