Dokumentum letöltése () 20
Működésbe hozzuk az igazán fontos dolgokat.*

115260
Modellkód: NZMB2-M125-BT

Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 125A, box terminals, B2-M125-BT

General specifications

Product Name
Eaton Moeller series NZM molded case circuit breaker thermo-magnetic
Catalog Number
115260
EAN
4015081146604
Product Length/Depth
149 mm
Product Height
206 mm
Product Width
140 mm
Product Weight
2.95 kg
Compliances
RoHS conform
Model Code
NZMB2-M125-BT

Műszaki adatok - villamos

Voltage rating
440 V - 440 V
Rated operational current
99 A (400 V AC-3)
Amperage Rating
125 A
Instantaneous current setting (Ii) - min
1000 A
Instantaneous current setting (Ii) - max
1750 A
Overload current setting (Ir) - min
100 A
Overload current setting (Ir) - max
125 A
Short-circuit release non-delayed setting - min
1000 A
Short-circuit release non-delayed setting - max
1750 A
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz
25 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz
25 kA
Rated operating power at AC-3, 230 V
37 kW
Rated operating power at AC-3, 400 V
55 kW
Electrical connection type of main circuit
Other
Handle type
Rocker lever
Direction of incoming supply
As required

Műszaki adatok - kommunikáció

Rated operational current
99 A (400 V AC-3)
Amperage Rating
125 A
Instantaneous current setting (Ii) - min
1000 A
Instantaneous current setting (Ii) - max
1750 A
Overload current setting (Ir) - min
100 A
Overload current setting (Ir) - max
125 A
Short-circuit release non-delayed setting - min
1000 A
Short-circuit release non-delayed setting - max
1750 A
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz
25 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz
25 kA
Rated operating power at AC-3, 230 V
37 kW
Rated operating power at AC-3, 400 V
55 kW
Electrical connection type of main circuit
Other
Handle type
Rocker lever
Direction of incoming supply
As required

Műszaki adatok - mechanikai

Mounting Method
Fixed
Built-in device fixed built-in technique
Degree of protection
IP20
Switch off technique
Thermomagnetic

Termékjellemzők exportja

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Authenticate Product

Enter your 16-17 digit serial number
The serial number you entered should not contain special charachter. The serial number you entered is not correct it should be of 16 or 17 digit. The serial number you entered was not found. Please try again or report this issue for further assistance. The serial number you entered does not match the product. Check your product's serial number and try again. Click here to navigate to the product page for the serial number you have entered The serial number is known to Eaton to be suspect, please try again or report this issue for further assistance..
Serial number
Reset The serial number is known to Eaton to be suspect, please try again or report this issue for further assistance. The Serial Number is not recognised by Eaton and is invalid. Please use this form to report this issue for further assistance..
Enter the 6 digit authentication code
The product you entered is suspect! Please try again or report this issue for further assistance. The authentication code you enter does not match our records for this serial number. Please try again, or report this issue for further assistance. Invalid Authentication code. Length must be 6 characters report this issue for further assistance. Authentication code is required report this issue for further assistance.
Complete Captcha challenge before authenticating.
Contact us to report-issue
x
Report an Issue
Please enter your full name.
x
Thank you, your issue has been submitted, our product team will contact with you soon.
Megjegyzés: Ha fájl(ok) hiányoznak a letöltött .zip csomagból, akkor az illető fájltípus nem támogatott tömeges letöltés esetén