A fotó reprezentatív
Download
Eaton XH300 web panel, 10" display, Ethernet, USB, Linux
| Product Name |
Eaton XH web panel
|
| Catalog Number |
199883
|
| EAN |
7640130099807
|
| Product Length/Depth |
269 mm
|
| Product Height |
58 mm
|
| Product Width |
174 mm
|
| Product Weight |
1.165 kg
|
| Certifications |
CE
EMC EN 61000-6-2 EN 61000-6-3 RoHS |
| Catalog Notes |
Heat dissipation with power consumption for 24 V, all ports and interfaces connected
|
| Model Code |
XH-303-10-A10-A00-2B
|
| Enclosure material |
Insulated material
|
| Features |
USB Host
Ethernet interface Fanless CPU and system cooling, natural convection-based passive cooling Portrait format |
| Fitted with: |
Color display
1 x USB host (built-in interface) |
| Degree of protection |
IP20, rear (according to EN 60529-1)
|
| Degree of protection (front side) |
NEMA 4X
IP65 |
| Fuse type |
Built-in fuse (not accessible)
|
| Lifespan |
50,000 h (Service life of back-lighting)
|
| Model |
Plastic enclosure and glass panel in plastic frame
|
| Mounting method |
Flush mounting - Clearance: Width x Height x Depth ≥ 30 mm (1.18")
Flush mounting - Inclination from vertical: ±45° (if using natural convection) |
| Protection against polarity reversal |
Yes
|
| Product category |
XH-300 HMI Webpanel
|
| Voltage type |
DC
|
| Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts
|
| Vibration resistance |
According to IEC/EN 60068-2-6
|
| Air pressure |
795 - 1080 hPa (operation)
|
| Ambient operating temperature - min |
0 °C
|
| Ambient operating temperature - max |
50 °C
|
| Ambient storage temperature - min |
-20 °C
|
| Ambient storage temperature - max |
60 °C
|
| Environmental conditions |
Condensation: prevent with appropriate measures
|
| Operating temperature - min |
0 °C
|
| Operating temperature - max |
0 °C
|
| Relative humidity |
10 - 95 % (non-condensing)
|
| Voltage dips |
5 ms from undervoltage (19.2 V DC)
≤ 10 ms from rated voltage (24 V DC) |
| Permissible voltage |
18.0 - 31.2 V DC, absolute with ripple
35 V DC (for a duration of < 100 ms) 18 - 31.2 V DC, battery powered (rated operating voltage -25 %/+30 %) 19.2 - 30 V DC, effective (rated operating voltage -20 %/+25 %) |
| Power consumption |
11.5 W typ.
Max. 15.4 W 2.5 W (USB Slave to USB Host) 12.5 W |
| Rated control supply voltage |
24 V DC (UAUX, -20 %/+25 %)
|
| Rated operational current (Ie) |
0.64 A
|
| Rated operational voltage |
24 V DC (power-supply - safety extra low voltage)
|
| Supply voltage at AC, 50 Hz - min |
0 V
|
| Supply voltage at AC, 50 Hz - max |
0 V
|
| Supply voltage at DC - min |
19.2 V
|
| Supply voltage at DC - max |
30 V
|
| Interfaces |
USB 2.0 host (not galvanically isolated)
Ethernet (100Base-TX/10Base-T) |
| Display lighting |
LED
Dimmable via software |
| Display type |
TFT
Color display, TFT |
| Luminance intensity |
800 cd/m²
|
| Number of colors of the display |
65536
|
| Screen size (diagonal) |
10.1 in
|
| Touch technology |
Capacitive multitouch
Multi-touch touch panel touch sensor |
| Memory |
DDR4-RAM: 2 GByte
eMMC: 8 GByte |
| Memory capacity |
2,000,000 kByte
|
| Operating system |
Linux
|
| Processor |
ARM Cortex-A53, Quad-Core, 1.8 GHz
|
| Equipment heat dissipation, current-dependent Pvid |
11.5 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Static heat dissipation, non-current-dependent Pvs |
11.5 W
|
| 10.2.2 Corrosion resistance |
Please enquire
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Please enquire
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Please enquire
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Please enquire
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Please enquire
|
| 10.3 Degree of protection of assemblies |
Please enquire
|
| 10.4 Clearances and creepage distances |
Please enquire
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|