Eaton XIOC Counter module for XC100/200, 24 V DC, 2x100kHz, 4DO(T)
Product Name |
Eaton XIOC Counter module
|
Catalog Number |
257907
|
EAN |
4015082579074
|
Product Length/Depth |
100 mm
|
Product Height |
95 mm
|
Product Width |
30 mm
|
Product Weight |
0.155 kg
|
Certifications |
IEC/EN 61131-2
UL CSA File No.: 012528 UL508 EN 50178 UL File No.: E135462 CSA-C22.2 No. 142-M UL Category Control No.: NRAQ CSA-C22.2 No. 0-M CSA CE CSA Class No.: 2252-01 |
Model Code |
XIOC-2CNT-100KHZ
|
Functions |
Single-axis positioning possible
Single-axis controller possible |
Admissible range |
20.4 – 28.8 V (11.8 – 14.4 V), Power supply
|
Current consumption |
200 mA (Ie), internal current consumption, Inputs
200 mA, Outputs |
Degree of protection |
IP20
|
Number of channels |
4, Output
|
Overvoltage category |
II
|
Pollution degree |
2
|
Protection class |
1
|
Rated frequency |
100 (25 with four-fold resolution)
|
Repetition rate |
1 s
|
Residual ripple |
≤ 5 %
|
Suitable for |
Counting
Incremental data detection |
Type |
Counter module
|
Used with |
XC100/200 (expandable with up to 15 XI/OC modules)
|
Impact resistance |
500 g/⌀ 50 mm ±25 g
|
Shock resistance |
15 g, Mechanical, Shock duration 11 ms
|
Vibration resistance |
10 - 57 Hz, ± 0.075 mm
57 - 150 Hz ± 1.0 mm |
Ambient operating temperature - min |
0 °C
|
Ambient operating temperature - max |
55 °C
|
Ambient storage temperature - min |
-25 °C
|
Ambient storage temperature - max |
70 °C
|
Emitted interference |
Class A (according to DIN/EN 55011/22)
|
Voltage dips |
10 ms
|
Terminals |
Optionally, screw terminals or spring-loaded terminals for digital/analog modules
|
Leakage current |
0.5 A
|
Power loss |
1.2 W
|
Rated control voltage (Uc) |
-5 - 8 V DC
|
Rated operational current (Ie) |
10 A
|
Rated operational voltage |
24 (12) V DC
|
Supply voltage at DC - min |
2 VDC
|
Supply voltage at DC - max |
5 VDC
|
Connection |
30-pole plug: XIOC-TERM30-CNT4, Connection of external input (max. 30 m cable length), Inputs
Of external output: 30-pole plug XIOC-TERM30-CNT4 30 pole connector required for counter module Screened, twisted pair cable, Output termination Screened, twisted pair cable, Inputs |
Counter limits |
0 - 4294967295 (32 bit)
|
Delay time |
1 ms, Outputs, Delay time from 0 to 1, Debounce OFF
1 ms, Outputs, Delay time from 1 to 0, Debounce OFF |
Input |
2 inputs (up to 100 kHz, 24 V DC or 5 V diff)
2 Analog inputs |
Input current |
4 mA (high signal)
Input B1-C: max. 35 A |
Input voltage |
12 - 24 V DC
± 5 V DC (differential) |
Load current |
Max. 20 mA (Ie)
Min. 1 mA |
Output |
Transistor (open collector)
4 Digital Transistor Outputs |
Pulse characteristics |
On ≥ 4 µs (minimum pulse width)
|
Voltage drop (Ud) |
1.5 V
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Potential isolation |
Outputs: Opto-isolated
Opto-isolated (Inputs) |
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
1.2 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|