Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 45 kW, RDC 60: 48 - 60 V DC, DC operation, Screw terminals
Product Name |
Eaton Moeller® series DILM contactor
|
Catalog Number |
239511
|
Model Code |
DILM95(RDC60)
|
EAN |
4015082395117
|
Product Length/Depth |
160 mm
|
Product Height |
170 mm
|
Product Width |
90 mm
|
Product Weight |
2.32 kg
|
Certifications |
CSA Class No.: 2411-03, 3211-04
UL IEC/EN 60947 CSA-C22.2 No. 60947-4-1-14 VDE 0660 CSA File No.: 012528 UL 60947-4-1 UL Category Control No.: NLDX UL File No.: E29096 CSA CE IEC/EN 60947-4-1 |
Catalog Notes |
Contacts according to EN 50012
|
Fitted with: |
Suppressor circuit in actuating electronics
|
Number of poles |
Three-pole
|
Application |
Contactors for Motors
|
Frame size |
FS4
|
Lifespan, mechanical |
10,000,000 Operations (DC operated)
|
Operating frequency |
3600 mechanical Operations/h (DC operated)
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
Contactors
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
Rated impulse withstand voltage (Uimp) |
8000 V AC
|
Residual current |
1 mA (with actuation of A1 - A2 by the electronics with "0" signal)
|
Resistance per pole |
0.6 mΩ
|
Suitable for |
Also motors with efficiency class IE3
|
Utilization category |
AC-3: Normal AC induction motors: starting, switch off during running
AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Voltage type |
DC
|
Shock resistance |
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms |
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature (enclosed) - min |
25 °C
|
Ambient operating temperature (enclosed) - max |
40 °C
|
Ambient storage temperature - min |
40 °C
|
Ambient storage temperature - max |
80 °C
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Emitted interference |
According to EN 60947-1
|
Interference immunity |
According to EN 60947-1
|
Terminal capacity (copper band) |
2 x (6 x 16 x 0.8) mm (Number of segments x width x thickness), Main cables
|
Terminal capacity (flexible with ferrule) |
2 x (10 - 50) mm², Main cables
1 x (0.75 - 2.5) mm², Control circuit cables 1 x (10 - 70) mm², Main cables 2 x (0.75 - 2.5) mm², Control circuit cables |
Terminal capacity (solid) |
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 4) mm², Control circuit cables |
Terminal capacity (solid/stranded AWG) |
18 - 14, Control circuit cables
Single 8…3/0, double 8…2/0, Main cables |
Terminal capacity (stranded) |
1 x (16 - 70) mm², Main cables
2 x (16 - 50) mm², Main cables |
Stripping length (main cable) |
24 mm
|
Stripping length (control circuit cable) |
10 mm
|
Screw size |
5 mm AF, Hexagon socket-head spanner, Terminal screw, Main cables
M3.5, Terminal screw, Control circuit cables M10, Terminal screw, Main cables |
Screwdriver size |
2, Terminal screw, Control circuit cables, Pozidriv screwdriver
0.8 x 5.5/1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver |
Tightening torque |
14 Nm, Screw terminals, Main cables
1.2 Nm, Screw terminals, Control circuit cables |
Rated breaking capacity at 220/230 V |
950 A
|
Rated breaking capacity at 380/400 V |
950 A
|
Rated breaking capacity at 500 V |
950 A
|
Rated breaking capacity at 660/690 V |
800 A
|
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
130 A
|
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V |
95 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
95 A
|
Rated operational current (Ie) at AC-3, 440 V |
95 A
|
Rated operational current (Ie) at AC-3, 500 V |
95 A
|
Rated operational current (Ie) at AC-3, 660 V, 690 V |
80 A
|
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V |
50 A
|
Rated operational current (Ie) at AC-4, 400 V |
50 A
|
Rated operational current (Ie) at AC-4, 500 V |
50 A
|
Rated operational current (Ie) at AC-4, 660 V, 690 V |
37 A
|
Rated operational current (Ie) at DC-1, 60 V |
110 A
|
Rated operational current (Ie) at DC-1, 110 V |
110 A
|