Eaton’s SC9000 Encapsulated Powerpole (EP) variable frequency drive (VFD), available up to 12000 hp, is an award-winning medium-voltage drive combining innovation and dependability to deliver power, control and energy efficiency in a compact footprint. The SC9000 EP medium-voltage VFD is designed for reliability even in harsh industrial environments including oil and gas, utility, mining, and water and wastewater.
Want to learn more?
View images of SC9000 EP medium-voltage variable frequency drive
Eaton's Synchronous Transfer System maximizes capital efficiency by operating multiple motors of varying hp with one single drive. The incorporation of Ampgard motor control with the double bus designs ensures superior performance. Learn more about synchronous drives transfers and benefits.
Energy efficiency is a powerful incentive to incorporate variable frequency drives but there is another major benefit to applying drives in medium-voltage applications: do more with less equipment. Learn 5 ways synchronous transfer VFDs reduce equipment costs and improve system reliability.
Each SC9000 EP medium-voltage VFD receives a burn in test with full voltage and current for a duration of up to 24 hours while connected to a fully rated medium-voltage motor.
POWER RATING | 300-6000 hp, 6500-12000 hp |
INPUT VOLTAGE RATING | 2400-13800 V |
OUTPUT VOLTAGE RATING |
0-2400 V 0-3300 V 0-4160 V Contact Eaton if higher output voltage is required |
BASIC IMPULSE LEVEL (BIL) |
60 kV BIL |
INTERRUPTING RATING | 50 kA rms symmetrical |
AMBIENT TEMPERATURE (WITHOUT DERATING) |
0 to 40 °C |
STANDARD OVERLOAD RATING (VARIABLE TORQUE) |
110% for 1 minute out of 10 minutes |
OPTIONAL OVERLOAD RATING (CONSTANT TORQUE) |
150% for 1 minute out of 10 minutes |
OUTPUT FREQUENCY |
1-120 Hz |
UL | 347A |
NEMA | ICS6/ICS7 |
CSA | C22.2 |
THIRD PARTY RECOGNITION/APPROVAL | UL/cUL available for most configurations |
SEISMIC QUALIFICATION | IBC |
ENCLOSURE TYPE |
Indoor with gaskets and filters |
ACCESSIBILITY |
Front |
INDOOR SECTION DIMENSIONS (TYPICAL) |
65" w x 50" d x 92" h to 218" w x 50" d x 92" h Consult factory for applications above 6,000 hp |
BUS INSULATION | Heat shrink sleeve |
BUS SUPPORTS | Glass polyester |
COOLING | Air cooled with heat pipes |
SWITCHING DEVICE |
Medium-voltage IGBT |
DEVICE MOUNTING |
Draw-out inverter |
ISOLATION TRANSFORMER | 24-pulse |
INPUT POWER CIRCUIT PROTECTION | Vacuum contactor with current limiting fuses |
HEAT LOSS | 23 W/hp (typical) Consult factory for applications above 6,000 hp |