Eaton Moeller® series M22 Bulkhead interface, RJ45 socket, 8/8, cat. 5e, Bezel: titanium
Product Name |
Eaton Moeller® series M22 Accessory Bulkhead interface
|
Catalog Number |
107413
|
EAN |
4015081071517
|
Product Length/Depth |
30 mm
|
Product Height |
30 mm
|
Product Width |
30 mm
|
Product Weight |
0.014 kg
|
Compliances |
CE Marked
|
Certifications |
UL 508
CSA Std. C22.2 No. 142 IEC 6113-2 UL report applies to both US and Canada Certified by UL for use in Canada IEC/EN 6113-2 UL File No.: E330994 UL CSA Class No.: none CSA-C22.2 No. 142 UL Category Control No.: DUXR, DUXR7 CE |
Catalog Notes |
RJ45 socket, 8/8, cat. 5e
|
Accessory/spare part type |
Accessory
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Contact material |
CuSn, gold-plated
|
Connection to SmartWire-DT |
No
|
Bezel color |
Titanium
|
Contact type |
1:1
|
Material |
Titanium front ring
|
Design |
RJ45
|
Degree of protection |
IP65 (with closed cover)
IP20 (with plug connected) NEMA 12 (with closed cover) |
Electrical accessory type |
Other
|
Rated operational voltage |
24 V AC
|
Resistance |
< 30 mΩ (volume resistance)
|
Mechanical accessory type |
Other
|
Insulation resistance |
≥ 100 MΩ
|
Lifespan, mechanical |
750 insertion cycles
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
80 °C
|
Ambient storage temperature - min |
-25 °C
|
Force for positive opening - min |
0 N
|
Heat dissipation capacity Pdiss |
0 W
|
Mounting depth |
70 mm
|
Nominal current |
1500 A
|
Limit value class |
5
|
Nominal voltage - max |
50 V
|
Opening diameter |
22.5 mm
|
Number of poles |
Eight-pole
|