Eaton Moeller series xEffect - FAZ-NA-DC MCB. FAZ-DC, 1-pole, tripping characteristic: C, rated current In: 10 A, Switchgear for export to North America (UL-listed)
| Product Name |
Eaton Moeller series xEffect - FAZ-NA-DC MCB
|
| Catalog Number |
113759
|
| EAN |
4015081132942
|
| Product Length/Depth |
105 mm
|
| Product Height |
75.5 mm
|
| Product Width |
17.7 mm
|
| Product Weight |
0.121 kg
|
| Compliances |
RoHS conform
|
| Certifications |
UL 489
UL 489, CSA C22.2 No. 5 IEC 60947-2 EN45545-2 IEC 61373 |
| Catalog Notes |
Positioned for medium inrush startup currents to provide protection for small transformers and pilot devices. Single packaging of single-pole curves B, C and D for select amperages only.
|
| Amperage Rating |
10 A
|
| Features |
Additional equipment possible
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Pollution degree |
2
|
| Degree of protection |
IP20
|
| Rated impulse withstand voltage (Uimp) |
4 kV
|
| Functional group |
Overcurrent protection
|
| Terminals (top and bottom) |
Screw-type with pressure plate
|
| Tripping characteristic |
C
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Built-in depth |
65.5 mm
|
| Connectable conductor cross section (multi-wired) - max |
25 mm²
|
| Connectable conductor cross section (multi-wired) - min |
1 mm²
|
| Connectable conductor cross section (solid-core) - max |
25 mm²
|
| Connectable conductor cross section (solid-core) - min |
1 mm²
|
| Current limiting class |
3
|
| Internal resistance at room temperature (single-pole, 50 Hz) |
16 mΩ
|
| Nominal current |
10 A
|
| Direction of incoming supply |
Polarity dependent
|
| Width in number of modular spacings |
1
|
| Voltage type |
DC
|
| Mounting position |
As required
|
| Overvoltage category |
III
|
| Number of poles |
Single-pole
|
| Functions |
Overload protection
Short Circuit protection |
| Release characteristic |
C
|
| Type |
|
| Application |
DC applications in industrial and commercial installations, utilities, OEM control panels, renewable energy systems, IT and data centre auxiliary circuits, railway and transportation systems, as well as branch and feeder circuit protection in UL-listed panels for North American installations.
|
| Selectivity class |
3
|
| Number of poles (protected) |
1
|
| Number of poles (total) |
1
|
| Rated insulation voltage (Ui) |
440 V
|
| Rated operational current for specified heat dissipation (In) |
10 A
|
| Rated operational voltage (Ue) - max |
250 V
|
| Rated service short-circuit breaking capacity (IEC/EN 60947-2) - Ics |
7.5 kA
|
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V |
10 kA
|
| Rated switching capacity (IEC/EN 60947-2) |
10 kA
|
| Power loss |
1.8 W
|