Eaton Moeller® series E58 Retroflective sensing sensor, Sn=3000mm, 4L, 10-30VDC, NPN, PNP, M18, insulated material, M12
| Product Name |
Eaton Moeller® series E58 Retroreflective sensor
|
| Catalog Number |
135653
|
| EAN |
4015081324460
|
| Product Length/Depth |
158.75 mm
|
| Product Height |
50.8 mm
|
| Product Width |
133.35 mm
|
| Product Weight |
0.32 kg
|
| Certifications |
UL
CE CSA-C22.2 No. 14 IEC/EN 60947-5-2 CSA CSA File No.: 50513 UL 508 UL File No.: E117028 CSA Class No.: 3211-07 UL Category Control No.: NRKH, NRKH7 |
| Type |
Optical sensors
|
| Features |
Polarized light
Right-angled beam |
| Electric connection type |
Connector M12
|
| Enclosure material |
Plastic
|
| Enclosure type |
Cylinder, screw-thread
|
| Operating mode |
Switching principle: Adjustable bright/dark switching
|
| Explosion safety category for dust |
None
|
| Explosion safety category for gas |
None
|
| Functions |
For combination with reflector
Reflected-light beam Short-circuit protection Protection against polarity reversal |
| Voltage type |
DC
|
| Connection type |
Plug-in connection M12 x 1
4-wire |
| Light type |
Polarity free red light
|
| Degree of protection |
IP67
NEMA 6 |
| Interface type |
Other
|
| LED indicator |
Status indication of Switching state: Red LED
|
| Switch function type |
Programmable/configurable
|
| Load current |
Max. 250 mA (Ie, NPN, 120 > 50°C)
Max. 100 mA (Ie, PNP) |
| Laser protection class |
None
|
| Shock resistance |
100 g, Mechanical, Shock duration 3 ms
|
| Optical surface material |
Plastic
|
| Output current (mA) - max |
100 mA
|
| Rated control supply voltage (Us) at DC - max |
30 V
|
| Rated control supply voltage (Us) at DC - min |
10 V
|
| Rated switching distance (Sn) |
3000 mm
|
| Sensor length |
76 mm
|
| Voltage rating - max |
30 V
|
| Safety type (IEC 61496-1) |
1
|
| Switching frequency |
500 Hz
|
| Sensing mode |
Light-/dark switching
|
| Switching output type |
NPN
|
| Sensor material |
Insulated material
|
| Product category |
Comet Series
|
| Response time |
1 ms
|
| Ambient operating temperature - max |
70 °C
|
| Ambient operating temperature - min |
-40 °C
|
| Diameter sensor |
18 mm
|
| Number of contact energized outputs with signalling function |
0
|
| Number of outputs (protected contact energized) |
0
|
| Number of outputs (protected semiconductor) |
0
|
| Number of outputs (semiconductor with signaling function) |
2
|
| Operational current (Ib) in the switched state at 24 V DC |
30 A
|
| Adjustment type |
Manual adjustment
|