Eaton XNE Digital input card XI/ON ECO, 24 V DC, 8DI
| Product Name |
Eaton XNE Accessory Input card
|
| Catalog Number |
140035
|
| EAN |
7640130120556
|
| Product Length/Depth |
129.5 mm
|
| Product Height |
74.5 mm
|
| Product Width |
13 mm
|
| Product Weight |
0.055 kg
|
| Certifications |
CE
CSA Class No.: 2252-01, 2252-81 IEC/EN 61000-6-2 CSA-C22.2 No. 142 UL Recognized UL report applies to both US and Canada UL Category Control No.: NRAQ, NRAQ7 IEC/EN 61000-6-4 Certified by UL for use in Canada IEC/EN 6113-2 UL File No.: E205091 cULus IEC/EN 61131-2 UL 508 Rated data for terminations according to IEC/EN 60947-7-1 |
| Catalog Notes |
Base modules without C-Connection already built in
|
| Type |
I/O module
|
| Features |
Fieldbus connection over separate bus coupler possible
|
| Air discharge |
According to EN 61100-4-2
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Electric connection type |
Plug-in connection
|
| Number of inputs (digital) |
8
|
| Burst impulse |
According to IEC/EN 61000-4-4
|
| Number of channels |
8
|
| Explosion safety category for dust |
None
|
| Environmental conditions |
Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation)
Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation) |
| Explosion safety category for gas |
None
|
| Output current |
0 A
|
| Mounting method |
Rail mounting possible
|
| Current consumption |
15 mA, from module bus, Analog input modules
1.5 mA, from supply terminal |
| Voltage type |
DC
|
| Input voltage |
-5 - 5 V (Digital inputs, low level)
11 - 30 V (Digital inputs, high level) 24 V DC (Digital inputs) |
| Contact discharge |
According to EN 61100-4-2
|
| Safety performance level (EN ISO 13849-1) |
None
|
| SIL (IEC 61508) |
None
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
0 °C
|
| Ambient storage temperature - max |
85 °C
|
| Ambient storage temperature - min |
-25 °C
|
| Equipment heat dissipation, current-dependent Pvid |
1.5 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Input current at signal 1 |
2 mA
|
| Number of HW-interfaces (industrial ethernet) |
0
|
| Number of HW-interfaces (other) |
1
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
0
|
| Number of HW-interfaces (RS-422) |
0
|
| Number of HW-interfaces (RS-485) |
0
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Surge rating |
According to IEC/EN 61000-4-5 Level 4
|
| Emitted interference |
30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3)
230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3) |
| Potential isolation |
Through optocoupler: yes
|
| Electromagnetic fields |
According to IEC EN 61100-4-2
|
| Radiated RFI |
IEC/EN 61100-4-6
|
| Drop and topple |
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
|
| Protocol |
Other bus systems
|
| Number of outputs (digital) |
0
|
| Relative humidity |
5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C)
|
| Connection type |
Push-In spring-cage terminals, Connection design in TOP direction
|
| Data transmission type |
None
|
| Rated operational voltage |
24 V DC (supply terminal)
|
| Degree of protection |
IP20
|
| Gauge pin |
A1 (according to IEC/EN 60947-1)
|
| Vibration resistance |
According to IEC/EN 60068-2-6
|
| Input delay |
100 µs (rising edge)
200 µs (falling edge) |
| Shock resistance |
Mechanical, According to IEC/EN 60068-2-27
Continuous according to IEC/EN 60068-2-29 |
| Functions |
Positive switching
|
| System accessory |
Yes
|
| Input current |
-1 - 1.5 mA (Digital inputs, low level)
2 - 5 mA (Digital inputs, high level) |
| Terminal capacity |
0.25 - 1.5 mm², solid, H07V-U
0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) 0.25 - 1.5 mm², flexible without ferrule, H07V-K 0.25 - 0.75 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) |
| Voltage dips |
According to EN 61131-2 (Voltage fluctuations/voltage dips)
|
| Number of HW-interfaces (wireless) |
0
|
| Number of interfaces (PROFINET) |
0
|
| Permitted voltage at input - max |
30 V
|
| Permitted voltage at input - min |
0 V
|
| Permitted voltage at output - max |
0 V
|
| Permitted voltage at output - min |
0 V
|
| Rated insulation voltage (Ui) |
500 V
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Static heat dissipation, non-current-dependent Pvs |
1.5 W
|
| Stripping length (main cable) |
8 mm
|
| Supply voltage at AC, 50 Hz - max |
0 VAC
|
| Supply voltage at AC, 50 Hz - min |
0 VAC
|
| Supply voltage at AC, 60 Hz - max |
0 VAC
|
| Supply voltage at AC, 60 Hz - min |
0 VAC
|
| Supply voltage at DC - max |
30 VDC
|
| Supply voltage at DC - min |
18 VDC
|
| Time delay at signal exchange - max |
0.3 ms
|
| Time delay at signal exchange - min |
0.1 ms
|
| Product category |
XNE Slice module
|