Eaton xEffect CS LV systems Switch- & Controlgear Enclosure. Wall enclosure, +mounting plate, HxWxD=600x800x300mm, 2 doors
| Product Name |
Eaton xEffect CS enclosure double door
|
| Catalog Number |
144209
|
| EAN |
4015081407194
|
| Product Length/Depth |
300 mm
|
| Product Height |
600 mm
|
| Product Width |
800 mm
|
| Product Weight |
35.5 kg
|
| Compliances |
RoHS conform
IEC/EN 62208; CE marking Series CS may be provided with metal sub-panel. No back mounted components are allowed between sub-panel and the back sheet metal enclosure |
| Certifications |
IEC/EN 62208
In accordance with Directive 2015/863/EU of the European Parliament and Council |
| Special features |
|
| Type |
|
| Features |
Wall build in
Pole fastening |
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
Meets the product standard's requirements.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply to enclosures without lifting aids.
|
| 10.2.6 Mechanical impact |
IK09
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
IP55
|
| 10.4 Clearances and creepage distances |
Is the panel builder's responsibility.
|
| 10.5 Protection against electric shock |
< 0.1 Ω; meets the product standard's requirements.
|
| 10.6 Incorporation of switching devices and components |
Is the panel builder's responsibility.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Ui = 1000 V AC
|
| 10.9.3 Impulse withstand voltage |
Does not apply to basic enclosures as defined in EN 62208.
|
| 10.9.4 Testing of enclosures made of insulating material |
Does not apply to metal enclosures.
|
| Fitted with: |
Including M6 threaded welded studs for earth conductor connections in the door:
Mounting plate Cover Door |
| Surface finishing |
Semi-textured
Gloss Structured powder spray polyester based paint finish Powder coating |
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
|
| Degree of protection |
IK09 (impact resistance)
Other IP55 IP23 (with ventilating plates) IK09 IEC: IP66, indoor |
| Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890) |
81 W
|
| Heat diss. ambient 35°C delta T: 20°C wall mount middle encl. top (IEC 60890) |
72 W
|
| Heat diss. ambient 35°C delta T:20°C wall mount starting encl. top (IEC 60890) |
76 W
|
| Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890) |
144 W
|
| Heat diss. ambient 35°C delta T: 35°C wall mount middle encl. top (IEC 60890) |
149 W
|
| Heat diss. ambient 35°C delta T:35°C wall mount starting encl. top (IEC 60890) |
157 W
|
| Material quality |
Other
|
| Color |
Gray
Light gray (RAL 7035) |
| Cover/door type |
Right, left
Standard closure 3 mm double-ward key (door interlock) Door hinges right Can be converted by user |
| Permissible load of the mounting plate according to IEC 62208 - max |
3000 N
|
| Number of hinges |
4
|
| Number of locks |
1
|
| RAL-number |
7035
|
| Thickness of mounting plate |
2 mm
|
| Weight of mounted components - max |
275 kg
|
| Ambient operating temperature details |
-25 °C - 40 °C
|
| Design type |
Canted and seam welded, including two M6 threaded bolts for earth conductor connections inside the enclosure.
|
| Material |
Steel plate
Steel |
| Mounting method |
Wall fastening
9 mm drilling dimensions for wall mounting (Back plate) Intermediate mounting |
| Functions |
Floor standing enclosure
|
| Installation type |
Floor standing wall model
|
| Cover/door angle |
120° door opening angle
|
| Cover/door profile |
2 door profiles
|
| Installation site |
Indoor installation
|
| Flange plate dimensions |
172 mm x 732 mm
|
| Surface treatment |
Structured powder spray polyester based paint finish
|
| Load capacity (door) |
5 kg
|
| Material thickness (body) |
1.5 mm
|
| Material thickness (bottom plate) |
2 mm
|
| Material thickness (door) |
1.5 mm
|
| Mounting plate height |
570 mm
|
| Mounting plate width |
750 mm
|
| Number of covers/doors |
2
|
| Number of F3A flanges |
3
|
| Load capacity (mounting plate) |
250 kg
500 kg payload, when brackets fitted in all four enclosure corners (vertically or horizontally) and the weights are symmetrically distributed within the enclosure. |
| Suitable for |
Metrical mounting
|
| Mounting plate material |
Sheet steel, hot-galvanized
|
| Permissible load of the enclosure according to IEC 62208 - max |
3250 N
|
| Permissible load of the door(s) according to IEC 62208 - max |
250 N
|
| Thermal dissipation (Delta T = 20 K) according to IEC/TR 60890 |
81 W
|
| Number of connector holes |
0
|