Eaton EU1S SWD power supply IP67 for 24VDC feeding 4 A in the SWD network
| Product Name |
Eaton EU1S Accessory Power supply
|
| Catalog Number |
174724
|
| EAN |
4015081712106
|
| Product Length/Depth |
85.6 mm
|
| Product Height |
20.1 mm
|
| Product Width |
56.9 mm
|
| Product Weight |
0.06 kg
|
| Certifications |
IEC/EN 61131-2
EN 50178 IEC/EN 60529 UL CSA Class No.: 3211-07 CSA CSA File No.: 2324643 UL Category Control No.: NKCR UL File No.: E29184 |
| Suitable as |
Segment module
|
| Features |
Fieldbus connection over separate bus coupler possible
Fieldbus connection over separate bus coupler possible |
| Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Electric connection type |
Plug-in connection
|
| Fitted with: |
Power supply module
Potential separation |
| Pollution degree |
3
|
| Connection |
SmartWire-DT plug connector SWD4-SF5-67
SmartWire-DT plug connector SWD4-SM5-67 |
| Burst impulse |
1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
1 kV, CAN/DP bus cable, Signal cable, according to IEC/EN 61131-2, Level 3 2 kV, Supply cable, according to IEC/EN 61131-2, Level 3 |
| Climatic proofing |
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3 |
| Connection to SmartWire-DT |
Yes
|
| Air pressure |
795 - 1080 hPa (operation)
|
| Explosion safety category for dust |
None
|
| Environmental conditions |
Condensation: permissible
|
| Explosion safety category for gas |
None
|
| Mounting method |
Screw fixing (M4)
Rail mounting possible Mounting section (Clip M20) Wall mounting/direct mounting DIN rail |
| Voltage type |
DC
|
| Mounting position |
As required
|
| Contact discharge |
4 kV, according to IEC/EN 61131-2, Level 2, ESD
|
| Overvoltage category |
II
|
| Safety performance level (EN ISO 13849-1) |
None
|
| SIL (IEC 61508) |
None
|
| Ambient operating temperature - max |
70 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
| Number of HW-interfaces (industrial ethernet) |
0
|
| Number of HW-interfaces (other) |
1
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
0
|
| Number of HW-interfaces (RS-422) |
0
|
| Number of HW-interfaces (RS-485) |
0
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Number of HW-interfaces (wireless) |
0
|
| Number of interfaces (PROFINET) |
0
|
| Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
| Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
| Surge rating |
0.5 kV, Supply cables/CAN/DP bus cable, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
|
| Electromagnetic fields |
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008) 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008) |
| Protection against polarity reversal |
Yes
|
| Connection type |
SWD: Socket, plug M12 (A-keyed), 5 pole
5-pin M12 socket (A-keyed), Supply voltage |
| Radiated RFI |
10 V (IEC/EN 61131-2:2008, Level 3)
|
| Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
| Radio interference class |
Class A (EN 55011)
|
| Degree of protection |
IP67
|
| Protocol |
Other bus systems
|
| Residual ripple |
≤ 5 % (input voltage)
|
| Rated control supply voltage |
24 V DC (UAUX, -15 %/+20 %)
|
| Functions |
For feeding supply voltage in order to connect additional SmartWire-DT modules (IP 67) and connected sensors/actuators
|
| Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
| Supply current |
4 A, Imax, Supply voltage UAux
|
| System accessory |
Yes
|
| Operating temperature - max |
70 °C
|
| Operating temperature - min |
-25 °C
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Static heat dissipation, non-current-dependent Pvs |
1 W
|
| Supply voltage at DC - max |
28.8 VDC
|
| Supply voltage at DC - min |
20.4 VDC
|
| Product category |
SmartWire-DT accessories
|
| Potential isolation |
Supply voltage UAUX: no
|
| Power loss |
Normally 1 W
|
| Rated operational voltage |
Typically UAUX -0.2 V (for 24 V DC slaves)
|
| Short-circuit protection |
No, external fuse FAZ Z3, Supply voltage UAux
|