Eaton Moeller® series EASY Control relays easyE4 with display (expandable, Ethernet), 24 V DC, Inputs Digital: 8, of which can be used as analog: 4, push-in terminal
| Product Name |
Eaton Moeller® series EASY Control relay
|
| Catalog Number |
197506
|
| EAN |
4015081940844
|
| Product Length/Depth |
58 mm
|
| Product Height |
90 mm
|
| Product Width |
72 mm
|
| Product Weight |
0.2 kg
|
| Compliances |
Eaton supports the product until its end of life
|
| Certifications |
UL File No.: E205091
CE UL hazardous location group A (acetylene) UL hazardous location group B (hydrogen) UL hazardous location group C (ethylene) UL hazardous location group D (propane) UL hazardous location class I UL hazardous location division 2 cULus Ordinary Location DNV TAA00002HT cULus Hazard Location UL File No.: E523283 EN 61131-2 IEC 61131-2 EN IEC 61000-6-3 IEC 61000-6-3 EN IEC 61010-2-201 IEC 61010-2-201 UL 61010-1 UL 61010-2-201 CSA C22.2 No. 61010-1 CSA C22.2 No. 61010-2-201 UL 121201 CSA C22.2 No. 213 |
| Catalog Notes |
Accuracy of the real-time clock depending on ambient air temperature - fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible
|
| Used with |
easyE4
|
| Type |
easyE4 base device
|
| Features |
Expandable
Networkable (Ethernet) Parallel connection of transistor outputs with resistive load, inductive load with external suppressor circuit, combination within a group - Group 1 Q1 to Q4 Display indication of 6 lines x 16 characters |
| Air discharge |
8 kV
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Cable type |
Ethernet: CAT5
|
| Fitted with: |
Display
Timer Keypad Real time clock Transistor output |
| Pollution degree |
2
|
| Accuracy |
± 2 s/day, Real-time clock to inputs (± 0.2 h⁄Year)
± 1 %, Repetition accuracy of timing relays (of values) ± 2 %, (I5, I6, I7, I8) ± 0.12 V, of actual value, within a single device (Analog Inputs) ± 3 %, of actual value, two easy devices (Analog Inputs) |
| Burst impulse |
2 kV, I/O port
2 kV, Power supply port 1 kV, communication port According to IEC/EN 61131-2 |
| Air pressure |
795 - 1080 hPa (operation)
|
| Category (EN 954-1) |
None
|
| Explosion safety category for dust |
None
|
| Environmental conditions |
Condensation: prevent with appropriate measures
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
| Indication |
LCD-display used as status indication of digital I/Os
|
| Input |
Voltage (DC)
|
| Output voltage |
U = Uₑ - 1 V (signal 1 at Iₑ = 0.5 A, transistor outputs)
Max. 1.0 V (at status 0 per channel, transistor outputs) |
| Explosion safety category for gas |
None
|
| Mounting method |
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Screw fixing using fixing brackets ZB4-101-GF1 (accessories) Front build in possible Rail mounting possible Wall mounting/direct mounting |
| Voltage type |
DC
|
| Mounting position |
Vertical
Horizontal |
| Output |
4 Transistor Outputs
max. 2 A total current Parallel connection of group 1 (Q1 to Q4) |
| Contact discharge |
6 kV
|
| Base type |
Yes
|
| Safety performance level (EN ISO 13849-1) |
None
|
| SIL (IEC 61508) |
None
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Display temperature - max |
55 °C
|
| Display temperature - min |
0 °C
|
| Equipment heat dissipation, current-dependent Pvid |
2 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
| Number of HW-interfaces (industrial ethernet) |
1
|
| Number of HW-interfaces (other) |
0
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
0
|
| Number of HW-interfaces (RS-422) |
0
|
| Number of HW-interfaces (RS-485) |
0
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Number of HW-interfaces (wireless) |
0
|
| Overvoltage category |
Power supply + Inputs + Extension interface: II
Power supply outputs + Outputs: II |
| Duty factor |
100 %
|
| Software |
EASYSOFT-SWLIC/easySoft
|
| Surge rating |
0.5 kV, Line-to-Line, Power supply port
1 kV, Line-to-Earth, Power supply port 1 kV, Line-to-Earth, I/O port 1 kV, Line-to-Earth, communication port According to IEC/EN 61131-2 |
| Cable length |
Digital inputs (DC): ≤ 100 m (unshielded)
Digital outputs: ≤ 100 m (unshielded) Analog inputs: ≤ 30 m (shielded) |
| Conversions |
Each CPU cycle for Analog inputs
|
| Electromagnetic fields |
10 V/m at 0.08 - 1.0 GHz (according to IEC/EN 61131-2)
3 V/m at 1.0 - 6 GHz (according to IEC/EN 61131-2) |
| Display type |
Monochrome
|
| Protection against polarity reversal |
Yes, for supply voltage
For transistor outputs (Caution: A short circuit will result if 0 V/earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles) |
| Number of inputs (analog) |
4
0 |
| Connection type |
Ethernet: RJ45 plug, 8-pole
Push in terminals |
| Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
| Immunity to line-conducted interference |
10 V (according to IEC/EN 61131-2)
|
| Radio interference class |
Class B (EN 61000-6-3)
|
| Number of outputs (digital) |
4
|
| Data transfer rate |
10/100 MBit/s
|
| Relative humidity |
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)
|
| Degree of protection |
IP20
|
| Delay time |
Digital inputs (24 V DC): 20 ms, from 0 to 1, Debounce ON
Digital inputs (24 V DC): 0.015 ms typ., from 0 to 1, Debounce OFF Digital inputs (24 V DC): 20 ms, from 1 to 0, Debounce ON Digital inputs (24 V DC): 0.015 ms typ., from 1 to 0, Debounce OFF |
| Residual current |
0.1 mA (on signal "1" per channel)
|
| Protocol |
Modbus TCP
|
| Residual ripple |
Power supply: ≤ 5 %
Power supply transistor outputs: 5 % |
| Rapid counter inputs |
Pulse pause ratio: 1:1
Counter frequency: ≤ 10 kHz Cable length: ≤ 20 m (shielded) Value range: -2147483648 to +2147483647 Pulse shape: Square Number of rapid counter inputs: 4 (I1, I2, I3, I4) |
| Rated operational current (Ie) |
Max. 0.5 A at signal „1” DC per channel
|
| Insulation resistance |
According to EN IEC 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-208
|
| Incremental counter |
Pulse shape: Square
Signal offset: 90° Counter frequency: ≤ 5 kHz Number of counter inputs: 2 (I1 + I2, I3 + I4) Pulse pause ratio: 1:1 Value range: -2147483648 to +2147483647 Cable length: ≤ 20 m (shielded) |
| Short-circuit current |
6.8 A, Transistor outputs
|
| Vibration resistance |
8.4 - 150 Hz, 1 g constant acceleration
5 - 8.4 Hz, 3.5 mm constant amplitude According to IEC/EN 61131-2 |
| Input impedance |
Analog: 13.3 kΩ
|
| Input current |
1.8 mA (I5 - I8, at 24 V DC,at signal 1)
3.3 mA (I1 - I4, at 24 V DC,at signal 1) < 1 mA (Analog inputs) |
| Shock resistance |
15 g, Mechanical, acc. to IEC/EN61131-2, Half-sinusoidal shock 11 ms, 18 Impacts
|
| Frequency counter |
Cable length: ≤ 20 m (shielded)
Counter frequency: ≤ 5 kHz Number: 4 (I1, I2, I3, I4) Pulse pause ratio: 1:1 Pulse shape: Square |
| Input voltage |
Condition 0: ≤ 5 V DC (Digital inputs, 24 V DC)
Condition 1: ≥ 15 V DC (Digital inputs, 24 V DC) |
| Short-circuit tripping current |
0.7 ≤ Ie ≤ 1.7 per output, For Ra ≤ 10 mΩ, Depending on number of active channels and their load, Transistor outputs
|
| Signal range |
0 - 10 V DC, Analog inputs
|
| Utilization factor |
1 / group, with ext. suppressor circuit
0.25 / group, w/o ext. suppressor circuit, T0.95 = 15ms/R = 48Ω/L = 0.24H 0.25 / group, w/o ext. suppressor circuit, DC-13/T0.95 = 72ms/R = 48Ω/L = 1.15 H Inductive load to EN 60947-5-1 |
| Potential isolation |
POW+Inputs+Extension interface vs. POW outputs+Outputs: yes
POW+Inputs+Extension interface vs. Ethernet+Functional Earth: yes Power supply outputs + Outputs against Ethernet + Functional Earth: yes |
| Number of inputs (digital) |
4
8 |
| Voltage dips |
10 ms
|
| Number of interfaces (PROFINET) |
0
|
| Number of outputs (analog) |
0
|
| Static heat dissipation, non-current-dependent Pvs |
2 W
|
| Supply voltage at DC - max |
28.8 VDC
|
| Supply voltage at DC - min |
20.4 VDC
|
| Switching current |
0.5 A
|
| Product category |
Control relays easyE4
|
| Resolution |
12 Bit (value 0 - 4095, Analog inputs)
|
| Power consumption |
2 W
|
| Rated operational voltage |
Power supply: 24 V DC (-15 %/+ 20 %)
Power supply transistor outputs: 24 V DC (-15 %/+ 20 %) Inputs: shall be identical to the power supply voltage |
| Short-circuit protection |
≥ 1A (T), Fuse, Power supply
Yes, electronic (Q1 - Q4), Transistor outputs |
| Switching frequency |
Depending on the suppressor circuit (Inductive load to EN 60947-5-1, With external suppressor circuit, Max. switching frequency, max. duty factor)
Dependent on the cycle time of the basic device |
| Terminal capacity |
0.2 - 2.5 mm², solid
0.2 - 2.5 mm², flexible 0.25 - 1,5 mm², solid or flexible with ferrule AWG 24 - 14, solid or stranded |