Eaton Moeller® series M22 AS-Interface module, 2I, 1Q, screw connection
| Product Name |
Eaton Moeller® series M22 AS-interface connection
|
| Catalog Number |
231269
|
| EAN |
4015082312695
|
| Product Length/Depth |
40 mm
|
| Product Height |
30 mm
|
| Product Width |
40 mm
|
| Product Weight |
0.023 kg
|
| Certifications |
UL File No.: E29184
CE CSA CSA-C22.2 No. 14-05 DIN EN 50295 UL UL 508 IEC/EN 60947 CSA Class No.: 3211-03 CSA File No.: 012528 UL Category Control No.: NKCR IEC/EN 60947-5 CSA-C22.2 No. 94-91 |
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Fitted with: |
AS-Interface connector as insulation piercing terminal
|
| Addressing |
Adress set via connection to AS-Interface cable
|
| Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
| Connection to SmartWire-DT |
No
|
| Bezel color |
Titanium
|
| Output voltage |
24 V DC (-15/+10 %)
|
| Mounting position |
As required
|
| Output |
1 (normally 19 V/8 mA) Output, protected against short-circuit
Output for 1 LED element: M22-LED-... |
| Connection type |
Front fixing for RMQ-Titan
|
| Cable length |
2 m connection cable
|
| Degree of protection |
IP20
|
| Power consumption |
40 mA
|
| Protocol |
AS-Interface (S-3.A.E)
|
| Number of modules |
62 (Suconet-K)
|
| Radio interference class |
EN 55022
EN 55011 |
| Rated operational voltage |
26.5 - 31.6 V DC (AS-Interface specification)
|
| Shock resistance |
30 g, Mechanical, Shock duration 11 ms
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| No-load current |
30 A
|
| Input |
2 Inputs (22 V/5 mA, protected against short-circuit)
Inputs for 2 contact elements (M22-K01 (N/C), M22-K10 (N/O)) |
| Interfaces |
2.1 (Output specification)
|
| LED indicator |
Status indication of AS-Interface power line in the switch front: Green LED on element back
Status indication of AS-Interface ERROR, failure of AS-Interface master in the switch front: Red LED on element back |
| Number of appliances to build in |
0
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Static heat dissipation, non-current-dependent Pvs |
1.3 W
|
| Product category |
Accessories
|
| Protection |
AS-Interface protected against polarity reversal
|