Eaton 5P G2 1440VA 1440W 120V Line-Interactive UPS - 8 NEMA 5-15R Outlets, Pre-Installed Cybersecure Network Card, 2U Rack/Tower
| Product Name |
Eaton 5P G2 UPS
|
| Catalog Number |
5P1500RTNG2
|
| UPC |
786687110910
|
| Product Length/Depth |
448 mm
|
| Product Height |
85.5 mm
|
| Product Width |
438 mm
|
| Product Weight |
23 kg
|
| Compliances |
ENERGY STAR certified
FCC part 15 class A RoHS |
| Certifications |
CAN/CSA C22.2
ICES IEC/EN 62040-1 UL 1778 |
| Topology |
Line-interactive
|
| Rack size |
2U
|
| VA rating |
1440 VA
|
| Package contents |
|
| Input frequency range |
50/60 Hz
|
| Number of Outputs 5-15R |
6
|
| Electric current - max |
12A
|
| Runtime graph |
|
| Battery management |
ABM technology (3-stage charging extends battery service life by 50% and provides advance warning for battery replacement)
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
15 min
|
| Relative humidity |
20-90% non-condensing
|
| Front Panel LCD Display |
LCD graphical display
|
| Input Plug Type |
NEMA 5-15P
|
| Output Receptacles |
5-15R
|
| Product Highlights |
Unity power factor (1.0) delivers full rated power to support modern IT loads
Pure sine wave output ensures compatibility and stability for sensitive equipment Exclusive ABM technology increases battery life by 50% Rack-friendly design is shorter in depth and 25% lighter than earlier 5P model Pre-installed NETWORK-M3 Gigabit network card enables full remote access and control |
| Nominal Output Voltage |
120V
|
| Network Management Cards |
NETWORK-M3
|
| Network Management Cards Details |
Slot with pre-installed Network-M3 network card
|
| Output power factor |
1
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
5 min. (1440W)
|
| Communication interface |
Included network card
RS-232 USB (HID enabled) |
| Battery Access |
Battery Door
|
| Dc Voltage |
48
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Load Management Receptacles |
2 Banks (2 outlets per bank)
|
| High Voltage Transfer to Battery Power |
151V +/-3%
|
| Low Voltage Transfer to Battery Power |
89V +/-3%
|
| Application |
|
| Switch configuration |
5 Buttons: Esc, Up, Down, Enter, On/Off; RPO / ROO; Relay Out
|
| AC suppression joule rating |
380
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine Wave
|
| Output AC waveform (battery mode) |
Pure sine wave
|
| Output Capacity (kVA) |
1.44
|
| Operating Elevation |
3000m
|
| Audible Alarms |
Audible alarm indicates utility failure, low-battery, overload, other UPS/Battery fault or remote shutdown
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| LED Indicators |
3 status-indicating LEDs (normal, battery mode, alarm); LED light Bar (Blue = Nominal, Yellow = Warning, Red = Alarm)
|
| Rechargeable Battery |
9 Hours
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Input Nominal Voltage Description |
Normal Mode: 120Vac (89-151 Vac); Extended Mode: 120V (70-153 Vac at <87% load)
|
| Nominal Voltage Details |
100V, 120V, 125V
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 151Vac (Normal) 70 to 153Vac (Extended)
|
| Plug Type |
NEMA 5-15P
|
| Maximum Input Amps |
12
|
| Minimum Required Rack Depth (cm) |
53.34
|
| Minimum Required Rack Depth (inches) |
21
|
| UPS Input Cord Length (m) |
3.1
|
| Power Mode Transfer Time |
10ms Typical
|
| Output Capacity (VA) |
1440
|
| Output Capacity (kW) |
1.44
|
| Included Accessories |
Rackmount hardware, Tower support stands
|
| UPS Input Connection Type |
5-15P
|
| Input Nominal Voltage |
120 VAC
|
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Remote management Sine wave output |
| Nominal Input Voltage Supported |
120 VAC
|