Eaton Tripp Lite series basic PDU, 1PH, 1U, 2 5-20P inputs, 10 ft cord, 16A, 100-125V, 6 Outlets (6) 5-20R
| Product Name |
Eaton Tripp Lite series basic PDU
|
| Catalog Number |
PDUB201U
|
| UPC |
037332256201
|
| Product Length/Depth |
3.94 in
|
| Product Height |
1.73 in
|
| Product Width |
17.24 in
|
| Product Weight |
5.2 lb
|
| Compliances |
RoHS
|
| Certifications |
NOM
UL 62368-1 CSA Std. C22.2 |
| Form factor |
1U
|
| Package contents |
|
| Operating Temperature |
32° to 104°F (0° to 40°C)
|
| Mounting direction |
Horizontal
|
| Material |
Metal
|
| Input connection |
(2) 5-20P
|
| Cord length |
10 ft
|
| Amperage Rating |
16A
|
| Electric current - max |
16
|
| Phase |
Single-phase
|
| Frequency rating |
50/60 Hz
|
| Number of Outputs 5-20R |
6
|
| Features |
Flex Center
|
| Output Receptacles |
5-15/20R
5-20R |
| LED indicators |
Front panel LEDs report UTILITY Input Power ON (green), BYPASS-MODE Switch Setting (yellow), MASTER Outlet Power ON (green), CONTROLLABLE GROUP Outlets Power ON (green)
|
| Recommended electrical service |
Works with most 2000 & 2200VA 100-125V UPS systems
|
| Receptacles |
5-20R
|
| Input Cord Length |
10 ft
|
| Switch configuration |
2 position Manual Transfer switch offers Break-Before-Make transfer between UPS and Utility operating modes with less than 8 milliseconds (typical) transfer time; Additional switch offers ENABLE/DISABLE control of the ECO Power-Saving feature
|
| Product Features |
(2) NEMA 5-20P
|
| Cord type |
Utility input cable (10 ft / 3m) / UPS input cable (4 ft / 1.2m)
|
| Amperage Rating Details |
Agency de-rated to 16A continuous
|
| Operating elevation |
0-10000 ft. (0-3000 m)
|
| Operating temperature range |
32° to 104°F (0° to 40°C)
|
| Output nominal voltage |
100-125V
|
| Relative humidity |
5% to 95% non-condensing
|
| Form Factors Supported |
Includes installation accessories for wall mount and 1U horizontal rackmount installation in 2 or 4 post equipment racks
|
| Output Capacity Details |
2kW (125V), 1.92kW (120V), 1.6kW (100V) / 20A total capacity (Agency de-rated to 16A); 16A max per 5-15/20R outlet
|
| Storage temperature |
-22° to 122°F (-30° to 50°C)
|
| Product Highlights |
Ideal for supporting critical IT equipment that require 24/7/365 uptime
Mounts into 1U of rack space or onto wall using included mounting hardware 2-year limited warranty (Worldwide) Dual UPS and utility input cables with NEMA 5-20P plugs deliver AC power ECO mode saves power by shutting down controlled outlet bank in certain conditions Transfers connected components to utility power with no downtime during UPS maintenance |
| PDU Plug Type |
5-20P
|
| PDU Type |
Hot-swap
|
| PDU Input Voltage |
100
120 125 |
| High Availability PDU Features |
Manual hot-swap bypass
|
| PDU Form Factor |
Horizontal (1U)
|
| Total Outlets |
6
|