Eaton Tripp Lite series basic PDU, 1PH, 1U, C20 input with 5 Adapters, 10 ft cord, 1.9-3.8kW, 16A, 120-240V, 14 Outlets (12) C13 (2) C14
| Product Name |
Eaton Tripp Lite series basic PDU
|
| Catalog Number |
PDUNV
|
| UPC |
037332127204
|
| Product Length/Depth |
4.25 in
|
| Product Height |
1.75 in
|
| Product Width |
19 in
|
| Product Weight |
3.2 lb
|
| Warranty |
5 year limited
|
| Compliances |
CE Marked
FCC Class A RoHS TAA Compliant EAC UKCA |
| Certifications |
CSA Std. C22.2
IEC 62368-1 UL 62368-1 |
| Form factor |
1U
|
| Package contents |
|
| Operating Temperature |
32° to 104°F (0° to 40°C)
|
| Mounting direction |
Horizontal
|
| Material |
Metal
|
| Input connection |
NEMA 5-15P; NEMA 5-20P; NEMA L5-20P; NEMA L6-20P; IEC-320 C14; IEC-320 C20
|
| Cord length |
10 ft
|
| Amperage Rating |
16A
|
| Electric current - max |
16
|
| Phase |
Single-phase
|
| Frequency rating |
50/60 Hz
|
| Number of Outputs C13 |
12
|
| Number of Outputs C19 |
2
|
| Features |
Flex Center
|
| Output Receptacles |
C13
C19 |
| Grounding options |
Grounding lug
|
| Minimum required rack depth |
7.8 in
|
| Outlet spacing |
Distance between Front (C13) outlets = 28.75mm; Distance between Rear (C19) outlets = 55mm; Distance between Rear (C13) outelts = 28.75mm
|
| Overload protection |
16A circuit breaker
|
| Recommended electrical service |
Single-phase 16/20A 120-240V service
|
| Output Receptacles Details |
Compatible with Eaton Tripp Lite Power Cords
|
| Receptacles |
|
| Input Cord Length |
10 ft
|
| Product Features |
C20 inlet accepts included C19-C20 cable with included plug adapters
NEMA 5-15P; NEMA 5-20P; NEMA L5-20P; NEMA L6-20P; IEC-320 C14; IEC-320 C20 |
| Operating elevation |
0-10000 ft. (0-3000 m)
|
| Operating temperature range |
32° to 104°F (0° to 40°C)
|
| Output nominal voltage |
120-240V
|
| Relative humidity |
5% to 95% non-condensing
|
| Form Factors Supported |
1U rackmount, 0U vertical mount, wallmount and under-counter mounting supported
|
| Output Capacity Details |
3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V), 2.03kW (127V), 1.92kW (120V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet
|
| Output Capacity (kW) |
1.9-3.8
|
| Storage temperature |
-22° to 122°F (-30° to 50°C)
|
| Product Highlights |
14 total outlets—12 C13 and 2 C19; Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability
5-year limited warranty (Worldwide) Reversible all-metal housing Switchless design prevents accidental shutdown 16A circuit breaker protects against overloads C20 input with 10 ft. (3.1 m) cord and 5 adapters |
| PDU Plug Type |
C14
C20 5-15 5-20 L5-20 6-20 |
| PDU Type |
Basic
|
| PDU Input Voltage |
120
208 230 240 |
| PDU Form Factor |
Horizontal (1U)
|
| Total Outlets |
14
|
| TAA Compliance |
No
|