Descargar documento () de 20
We make what matters work*

PDUNV

Eaton Tripp Lite series basic PDU, 1PH, 1U, C20 input with 5 Adapters, 10 ft cord, 1.9-3.8kW, 16A, 120-240V, 14 Outlets (12) C13 (2) C14

Especificaciones generales

Product Name
Eaton Tripp Lite series basic PDU
Catalog Number
PDUNV
UPC
037332127204
Product Length/Depth
4.25 in
Product Height
1.75 in
Product Width
19 in
Product Weight
3.2 lb
Warranty
5 year limited
Compliances
CE Marked
FCC Class A
RoHS
TAA Compliant
EAC
UKCA
Certifications
CSA Std. C22.2
IEC 62368-1
UL 62368-1

Especificaciones del producto

Form factor
1U
Package contents
  • PDUNV 1.6/3.8kW Single-Phase 120-240V Basic PDU
  • (5) C19 plug adapters
  • Mounting brackets
  • Owner’s manual
Operating Temperature
32° to 104°F (0° to 40°C)
Mounting direction
Horizontal
Material
Metal
Input connection
NEMA 5-15P; NEMA 5-20P; NEMA L5-20P; NEMA L6-20P; IEC-320 C14; IEC-320 C20
Cord length
10 ft
Amperage Rating
16A
Electric current - max
16
Phase
Single-phase
Frequency rating
50/60 Hz
Number of Outputs C13
12
Number of Outputs C19
2
Features
Flex Center
Output Receptacles
C13
C19
Grounding options
Grounding lug
Minimum required rack depth
7.8 in
Outlet spacing
Distance between Front (C13) outlets = 28.75mm; Distance between Rear (C19) outlets = 55mm; Distance between Rear (C13) outelts = 28.75mm
Overload protection
16A circuit breaker
Recommended electrical service
Single-phase 16/20A 120-240V service
Output Receptacles Details
Compatible with Eaton Tripp Lite Power Cords
Receptacles
  • C13
  • C19
Input Cord Length
10 ft
Product Features
C20 inlet accepts included C19-C20 cable with included plug adapters
NEMA 5-15P; NEMA 5-20P; NEMA L5-20P; NEMA L6-20P; IEC-320 C14; IEC-320 C20
Operating elevation
0-10000 ft. (0-3000 m)
Operating temperature range
32° to 104°F (0° to 40°C)
Output nominal voltage
120-240V
Relative humidity
5% to 95% non-condensing
Form Factors Supported
1U rackmount, 0U vertical mount, wallmount and under-counter mounting supported
Output Capacity Details
3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V), 2.03kW (127V), 1.92kW (120V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet
Output Capacity (kW)
1.9-3.8
Storage temperature
-22° to 122°F (-30° to 50°C)
Product Highlights
14 total outlets—12 C13 and 2 C19; Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability
5-year limited warranty (Worldwide)
Reversible all-metal housing
Switchless design prevents accidental shutdown
16A circuit breaker protects against overloads
C20 input with 10 ft. (3.1 m) cord and 5 adapters
PDU Plug Type
C14
C20
5-15
5-20
L5-20
6-20
PDU Type
Basic
PDU Input Voltage
120
208
230
240
PDU Form Factor
Horizontal (1U)
Total Outlets
14
TAA Compliance
No

Exportar especificación del producto