TAA-Compliant SmartPro 120V 3kVA 2.25kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, Extended Run, Pre-Installed WEBCARDLX Network Interface, LCD, USB, DB9 Serial
Product Name |
Eaton Tripp Lite series SmartPro UPS
|
Catalog Number |
SM3000RM2UNTAA
|
UPC |
037332184214
|
Product Length/Depth |
22.2 in
|
Product Height |
8.8 in
|
Product Width |
23.9 in
|
Product Weight |
62.8 lb
|
Compliances |
FCC Class A
RoHS TAA Compliant |
Certifications |
UL 1778
NOM CSA certified |
Topology |
Line-interactive
|
Form factor |
Rackmount/Tower
|
Rack size |
2U
|
Package contents |
|
Input nominal voltage |
120 VAC
|
Nominal frequency |
60 Hz
|
Input frequency range |
60 Hz
|
Receptacle |
|
Output nominal voltage |
110 / 120V
|
Electric current - max |
24A
|
Battery replacement |
RBC94-2U
|
Runtime at half load |
10 min
|
Noise level |
45 dBA maximum, front side 1m
|
Relative humidity |
0-95% non-condensing
|
Front Panel LCD Display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
|
Output Receptacles |
L5-30R
5-15/20R |
Product Features |
Individually Controllable Load Banks
Expandable Runtime |
Product Highlights |
120V nominal output during brownouts to 83V and overvoltages to 145V
Interactive LCD, USB, RS232, EPO and pre-installed WEBCARDLX Network Interface 3kVA / 3000VA / 2250W line interactive 2U rack/tower UPS NEMA L5-30P input, 8 NEMA 5-15/20R and 1 L5-30R outlets Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases To enable the Auto Probe feature, this product requires LX firmware update 15.5.2 or later to be installed Hot-swap batteries, 98% efficiency, Sine wave output, 2 switchable load banks |
PowerAlert Software |
For local monitoring via the UPS’s built-in Serial or USB communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert. LX Platform Interface: PowerAlert Device Manager 20 (PADM20)
|
SNMP Compatibility |
SNMP V1, V2c, V3
|
Nominal Output Voltage |
110 / 120V
|
Network Management Cards |
WEBCARDLXE
|
Network Management Cards Details |
Network management card included
|
Output power factor |
0.75
|
Phase (input) |
Single-phase
|
Runtime at full load |
3.5 min. (2250W)
|
Communication interface |
EPO (emergency power off)
Slot for SNMP / Web interface Pre-installed network card USB (HID enabled) Micro-USB, USB and DB9 cabling included DB9 Serial |
Battery Access |
Front panel battery access door
|
Typical Battery Runtime |
Expandable Runtime
|
Expandable Runtime Description |
Output with external battery pack configurations is limited to 1600 watts maximum
|
EPO Port |
RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems
|
Dc Voltage |
48
|
Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
Communications Cable |
Micro-USB, USB and DB9 cabling included
|
Grounding Details |
Includes back panel grounding lug
|
Optional Mounting Accessory Notes |
Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
|
Output Circuit Breakers |
Two 20A output breakers protect 4 5-15/20R outlets each
|
Load Management Receptacles |
Two switchable single-outlet load banks
|
High Voltage Transfer to Battery Power |
145
|
Low Voltage Transfer to Battery Power |
83
|
Undervoltage Correction |
Input voltages between 108 and 96 are boosted by 12%
|
Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
Application |
Large Network
|
Switch configuration |
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions. . LX Platform Interface: Recessed reset switch for interface reboot and factory reset
|
AC suppression joule rating |
570
|
Housing material |
Steel
|
Output AC waveform (AC mode) |
Pure Sine wave
|
Output AC waveform (battery mode) |
Pure Sine wave
|
Output Capacity (kVA) |
3
|
Output Capacity (kW) |
2.25
|
Output Capacity (VA) |
3000
|
Operating Elevation |
|
Primary UPS Depth (mm) |
494
|
Primary UPS Height (mm) |
88
|
Primary UPS Width (mm) |
440
|
AC Suppression Response Time |
Instantaneous
|
Alarm Interface |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
|
Audible Alarms |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
|
Battery Start Capability |
Cold-start operation supported
|
Cooling Method |
Fan
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
LED Indicators |
Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).
|
Minimum Required Rack Depth With External Battery Pack |
26.5
|
Minimum Required Rack Depth Without External Battery Pack |
25
|
Output Voltage Regulation (Line Mode) |
-14%, +6%
|
Output Voltage Regulation(Battery Mode) |
+/- 5%
|
Overvoltage Correction |
Input voltages between 127 and 145 are reduced by 12%
|
Rechargeable Battery |
Less than 4.5 hours from 10% to 90%
|
Recommended Electrical Service |
30A 120V
|
Storage Temperature |
5° to 122°F (-15° to 50°C)
|
Included Mounting Accessory Description |
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
|
Network Monitoring Port |
RJ45 Network port, Micro-USB Configuration/Console port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
|
Network Monitoring Port Description |
Includes pre-installed WEBCARDLX Network Management Card
|
Nominal Voltage Details |
120v nominal output in battery mode
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Maximum Input Amps |
24
|
Minimum Required Rack Depth (cm) |
58.42
|
Minimum Required Rack Depth (inches) |
23
|
UPS Input Cord Length (m) |
3.1
|
UPS Power Module Dimensions |
3.46 x 17.32 x 19.46
|
Power Mode Transfer Time |
5 milliseconds (AC to battery); 1 millisecond (battery to AC)
|
Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
Optional Accessories |
2 post rackmount (2POSTRMKITWM)
2-4 post front rail rackmount (UPSHDEARKIT) 4 post rackmount short-depth (4POSTRAILKITWM) Tower (2-9USTAND) Wallmount (2POSTRMKITWM) |
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
UPS Input Connection Type |
L5-30P
|
External Battery Pack Compatibility |
BP48V24-2U (limit 1)
BP48V242UTAA (limit 1) BP48V27-2US (multi-pack compatible) BP48V60RT-3U (multi-pack compatible) BP48V60RT3UTAA (multi-pack compatible) |
Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
Individually controllable load banks |
UPS Dataline Suppression |
1 line TEL/DSL or Ethernet
|
High Availability UPS Features |
Hot swappable batteries
Auto probe monitoring and reboot (included) Surge/noise protection Automatic voltage regulation (AVR) Remote management |