TAA SmartPro 208/120V 5kVA 4kW Line-Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SM5000RT3UTAA
|
| UPC |
037332161475
|
| Product Length/Depth |
22.5 in
|
| Product Height |
10.5 in
|
| Product Width |
17.53 in
|
| Product Weight |
256.14 lb
|
| Compliances |
RoHS
FCC Class A TAA Compliant |
| Certifications |
UL 1778
CSA certified NOM |
| Rack size |
6U
|
| VA rating |
5000 VA
|
| Package contents |
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
38 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Input Plug Type |
NEMA L6-30P
|
| Output Receptacles |
L14-30R
5-15R L6-30R 5-15/20R |
| Product Features |
Individually Controllable Load Banks
Expandable Runtime |
| Product Highlights |
To use the Auto Probe feature, this product requires a WEBCARDLX network interface (sold separately) running LX firmware update 15.5.2 or later
Expandable runtime, 8 single-outlet switched output load banks USB, RS232, EPO and slot for network communication card options 208 and 120V output during brownouts to 151V and overvoltages to 260V Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases NEMA L6-30P input, 10 5-15R, 2 5-15/20R, 1 L6-30R and 1 L14-30R outlets 2-year limited warranty (Worldwide) 5kVA / 5000VA / 4000W line interactive 6U rack/tower UPS, Sine wave output |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
110V
115V 120V 208V |
| Network Management Cards |
WEBCARDLXE
|
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.8
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
16 min. (4000W)
|
| Communication interface |
USB
DB9 Serial Slot for SNMP / Web interface USB and DB9 serial cables included |
| Typical Battery Runtime |
Expandable Runtime
|
| EPO Port |
RJ-11 style 4-wire connection jack with included 4-wire cable to connect to facility/room EPO system
|
| Dc Voltage |
48
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Grounding Details |
Back panel grounding lug
|
| Input Circuit Breakers |
30A double-pole
|
| Optional Mounting Accessory Notes |
2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack
|
| Output Circuit Breakers |
15A branch rated (x3) - 2 breakers support 5 5-15R outlets each, one breaker supports 2 5-20R outlets, L6-30R and L14-30R outlets are unbreakered
|
| Load Management Receptacles |
Eight switchable single-outlet 5-15R load banks
|
| High Voltage Transfer to Battery Power |
282V
|
| Low Voltage Transfer to Battery Power |
151V
|
| Undervoltage Correction |
Input voltages between 180V and 199 are boosted by 12%
|
| Application |
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation
|
| AC suppression joule rating |
1020
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
5
|
| Output Capacity Details |
Maximum output increases to 4800W when hardwired or a user supplied 50A rated input plug is used
|
| Primary UPS Depth (mm) |
572
|
| Primary UPS Height (mm) |
132
|
| Primary UPS Width (mm) |
445
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure, overload and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fans
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
5 LEDs indicate line power, battery power, load state, voltage regulation, and battery replace/fault status
|
| Minimum Required Rack Depth With External Battery Pack |
29.5
|
| Minimum Required Rack Depth Without External Battery Pack |
28.25
|
| Output Voltage Regulation (Line Mode) |
208 & 120V (-10%, +20%)
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Input voltages between 240V and 260V are reduced by 12%
|
| Rechargeable Battery |
3 hours
|
| Recommended Electrical Service |
30A 208V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Form factor |
Rackmount
Tower |
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)
|
| Nominal Voltage Details |
208/120V nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 260V
|
| Minimum Required Rack Depth (cm) |
7.62
|
| Minimum Required Rack Depth (inches) |
3
|
| Unit Dimension Details |
Includes 3U UPS/power module and 3U external battery pack
|
| UPS Input Cord Length (m) |
3.1
|
| UPS Power Module Dimensions |
5.2 x 17.5 x 22.5
|
| Power Mode Transfer Time |
2-4 milliseconds
|
| TAA Compliance |
Yes
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance |
| Optional Accessories |
2 post rackmount (2POSTRMKITHD)
Tower (2-9USTAND) |
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
L6-30P
|
| External Battery Pack Compatibility |
BP48V60RT3UTAA (multi-pack compatible)
|
| Input Nominal Voltage |
208 VAC
|
| High Availability UPS Features |
Auto probe monitoring (requires WEBCARDLXE)
Expandable battery backup Hot swappable batteries Sine wave output Surge/noise protection Automatic voltage regulation (AVR) |
| Nominal Input Voltage Supported |
208 VAC
|