SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART1500LCD
|
| UPC |
037332126146
|
| Product Length/Depth |
10.5 in
|
| Product Height |
3.5 in
|
| Product Width |
17.25 in
|
| Product Weight |
30 lb
|
| Compliances |
RoHS
FCC Class B TAA Compliant |
| Certifications |
CSA certified
UL 1778 NOM |
| Topology |
Line-interactive
|
| Form factor |
Rackmount
|
| Rack size |
2U
|
| Package contents |
|
| Input nominal voltage |
120 VAC
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
|
| Battery replacement |
RBC1500
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
11.8 min
|
| Relative humidity |
Up to 95% non-condensing
|
| Front Panel LCD Display |
Backlighted LCD screen offers detailed UPS status information, configuration options and Error message reporting; STATUS INFORMATION includes Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load Percentage, Output Load Wattage, Battery Charge Percentage, Graphical 5-Bar Battery Charge Level and UPS Operating Mode Display / CONFIGURATION OPTIONS include Power Sensitivity, LCD Status Information Scrolling, Alarm Disable, LCD Brightness and Self Test / REPORTED ERROR MESSAGES include Replace-Battery and Overload conditions; LCD Screen rotates for vertical or horizontal UPS placement
|
| Output Receptacles |
5-15R
|
| Product Highlights |
Front-panel LCD reports detailed voltage, runtime, load and battery information
Maintains continuous 120V nominal output during brownouts and overvoltages Keeps AC power running during blackouts to allow time for file saves and safe shutdown ENERGY STAR-certified to save electricity, lower costs and protect the environment Protects equipment against blackouts, brownouts, overvoltages, surges and line noise |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
110V
115V 120V |
| Network Management Cards Details |
Network management not supported
|
| Output power factor |
0.6
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
4.4 min. (900W)
|
| Communication interface |
Contact closure
USB (HID enabled) DB9 Serial USB and DB9 Serial cabling included |
| Battery Access |
Battery Access Door
|
| Dc Voltage |
24
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 Serial cabling included
|
| Input Circuit Breakers |
10A
|
| High Voltage Transfer to Battery Power |
147
|
| Low Voltage Transfer to Battery Power |
75
|
| Undervoltage Correction |
Input voltages between 93 and 107 are boosted by 14%
|
| Application |
|
| Switch configuration |
ON/OFF/MODE button provides UPS on/off power control (long-press) and advances the LCD screen display (short tap); MUTE/ENTER button provides temporary alarm cancel, plus selection and confirmation of on-screen configuration options
|
| AC suppression joule rating |
870
|
| Housing material |
ABS
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
1.5
|
| Output Capacity (kW) |
0.9
|
| Output Capacity (VA) |
1500
|
| Operating Elevation |
2000
|
| Primary UPS Depth (mm) |
267
|
| Primary UPS Height (mm) |
89
|
| Primary UPS Width (mm) |
438
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure and low-battery status; Alarm can be disabled entirely via front panel LCD interface (see manual)
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
IMPORTANT BATTERY REPLACEMENT INFORMATION > If your SMART1500LCD UPS has no battery replacement door, please contact a local electronics repair technician to source and install a matching replacement battery; If your SMART1500LCD UPS is equipped with a battery access door, please order Tripp Lite RBC1500 (quantity 1) replacement battery cartridge
|
| LED Indicators |
Front panel LCD display
|
| Output Voltage Regulation (Line Mode) |
-18%, +8%
|
| Output Voltage Regulation(Battery Mode) |
115V (+/- 5%)
|
| Overvoltage Correction |
Input voltages between 128 and 147 are reduced by 12%
|
| Rechargeable Battery |
Less than 4.5 hours from 10% to 90%
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Included Mounting Accessory Description |
Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4 rubber-feet enable no-slip horizontal desktop placement
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; DB9 provides contact-closure notification of AC Present (pins 1,9 connected) and AC Fail (pins 1,8 connected)
|
| Nominal Voltage Details |
115v nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
9
|
| Minimum Required Rack Depth (cm) |
35.56
|
| Minimum Required Rack Depth (inches) |
14
|
| UPS Dataline Suppression Details |
168 joules; Compatible with POE applications
|
| UPS Input Cord Length (m) |
1.8
|
| UPS Power Module Dimensions |
3.5 x 17.25 x 10.5
|
| Power Mode Transfer Time |
4 milliseconds (AC to battery mode); 1 millisecond (Battery to AC mode)
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
Right-Angled |
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
| UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out)
10/100Base T Ethernet |
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Hot swappable batteries Surge/noise protection |