SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, AVR, Extended Runtime, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART1500LCDXL
|
| UPC |
037332159885
|
| Product Length/Depth |
10.68 in
|
| Product Height |
3.49 in
|
| Product Width |
17.33 in
|
| Product Weight |
29.27 lb
|
| Warranty |
2 year limited
|
| Compliances |
RoHS
FCC Class B TAA Compliant |
| Certifications |
NOM
UL 1778 CSA certified |
| Topology |
Line-interactive
|
| Rack size |
2U
|
| VA rating |
1500 VA
|
| Package contents |
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
|
| Battery replacement |
RBC1500
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
12 min
|
| Relative humidity |
Up to 95% non-condensing
|
| Front Panel LCD Display |
LCD interface reports Input Voltage, Output Voltage, Battery Charge Percentage, Estimated Runtime in Minutes, Load Percentage, Load Watts; Additional LCD icons report battery charge level (5 "bars"), Line Power Mode, Battery Mode, Replace Battery and Auto-Voltage Regulation / AVR status; LCD interface control options include Alarm Disable, Display Scrolling, Initiate Self-test, LCD brightness, External Battery setting and line sensitivity
|
| Input Plug Type |
NEMA 5-15P
|
| Output Receptacles |
5-15R
|
| Product Features |
Expandable Runtime
|
| Product Highlights |
Extends runtime with optional BP24V15RT2U external battery pack
Supports a half-load (450W) up to 12 min. during power outage 2-year limited warranty (Worldwide) Features 8 protected NEMA 5-15R outlets Offers automatic voltage regulation (AVR) Supports a full load (900W) up to 4 min. during power outage |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
110V
115V 120V |
| Network Management Cards Details |
Network management not supported
|
| Output power factor |
0.6
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
4.18 min. (900W)
|
| Communication interface |
USB (HID enabled)
DB9 Serial Contact closure USB and DB9 Serial cabling included |
| Battery Access |
Battery access door enables hot-swappable, user replaceable internal battery
|
| Typical Battery Runtime |
Expandable Runtime
|
| Expandable Runtime Description |
Extended runtime supported via optional external battery pack (limit 1)
|
| Dc Voltage |
24
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 Serial cabling included
|
| Input Circuit Breakers |
10A
|
| High Voltage Transfer to Battery Power |
147
|
| Low Voltage Transfer to Battery Power |
75
|
| Undervoltage Correction |
Input voltages between 93 and 107 are boosted by 14%
|
| Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
| Application |
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation
|
| AC suppression joule rating |
1038
|
| Housing material |
Polycarbonate
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
1.5
|
| Output Capacity (Watts) |
900
|
| Operating Elevation |
2000
|
| Primary UPS Depth (mm) |
267
|
| Primary UPS Height (mm) |
89
|
| Primary UPS Width (mm) |
439
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure and low-battery conditions; Alarm can be permanently silenced via LCD interface
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Output Voltage Regulation (Line Mode) |
-18%, +8%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Input voltages between 128 and 147 are reduced by 12%
|
| Rechargeable Battery |
Less than 4.5 hours from 10% to 90%
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Form factor |
Rackmount
Tower |
| Included Mounting Accessory Description |
Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4 rubber-feet enable no-slip horizontal desktop placementinstallation
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; DB9 port also supports contact-closure messaging for power-fail (pins 1 & 9) and power-restored (pins 1, 8)
|
| Nominal Voltage Details |
115v nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
9
|
| Minimum Required Rack Depth (cm) |
35.56
|
| Minimum Required Rack Depth (inches) |
14
|
| UPS Input Cord Length (m) |
1.8
|
| UPS Power Module Dimensions |
3.5 x 17.3 x 10.5
|
| Power Mode Transfer Time |
4 milliseconds AC to battery mode / 3 milliseconds battery to AC mode
|
| Total Outlets |
8
|
| Output Capacity (VA) |
1500
|
| TAA Compliance |
Yes
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance |
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
Right-Angled |
| External Battery Pack Compatibility |
BP24V15RT2U (limit 1)
|
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
| Input Nominal Voltage |
110V AC
|
| UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out)
10/100Base T Ethernet |
| High Availability UPS Features |
Hot swappable batteries
Surge/noise protection Automatic voltage regulation (AVR) |
| Nominal Input Voltage Supported |
120V AC
115V AC 110V AC |