SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, Network Card Options, USB, DB9, 8 Outlets
Product Name |
Eaton Tripp Lite series SmartPro UPS
|
Catalog Number |
SMART1500SLT
|
UPC |
037332119896
|
Product Length/Depth |
17.6 in
|
Product Height |
13.9 in
|
Product Width |
9.7 in
|
Product Weight |
45 lb
|
Compliances |
FCC Class A
RoHS |
Certifications |
UL 1778
NOM CSA certified |
Topology |
Line-interactive
|
Form factor |
Tower
|
Package contents |
|
Input nominal voltage |
120V default (100/110/120V)
|
Nominal frequency |
50/60 Hz
|
Input frequency range |
50/60 Hz
|
Receptacle |
5-15R
|
Output nominal voltage |
100/110/120V
|
Electric current - max |
10.1A (100V), 9.3A (110V), 8.6A (120V)
|
Battery replacement |
RBC36-SLT
|
Runtime at half load |
20 min
|
Noise level |
Audible Noise < 50 dBA at Front Side 1 Meter
|
Relative humidity |
0-95% non-condensing
|
Output Receptacles |
5-15R
|
Product Features |
Individually Controllable Load Banks
|
Product Highlights |
Monitoring of power conditions via PowerAlert®
20 min. runtime at half load; 8 min. at full load 8 NEMA 5-15R outlets Corrects under- and overvoltages from 95V to 145V Front-panel LEDs indicate load, power and battery statuses Designed for commercial applications; see product description for home-use recommendations Monitoring of power conditions via PowerAlert® |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
Nominal Output Voltage |
100/110/120V
|
Network Management Cards |
WEBCARDLXE
RELAYIOCARD |
Network Management Cards Details |
Network management card optional
|
Output power factor |
0.63
|
Phase (input) |
Single-phase
|
Runtime at full load |
8 min. (900W)
|
Communication interface |
DB9 Serial
Slot for SNMP / Web interface USB (HID enabled) USB and DB9 serial cables included |
Battery Access |
Battery access door
|
Dc Voltage |
36
|
Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
Communications Cable |
USB and DB9 cabling included
|
Input Circuit Breakers |
15A
|
High Voltage Transfer to Battery Power |
145V (120V), 133V (110V), 121V (100V); All voltage setpoints ±5% tolerance
|
Low Voltage Transfer to Battery Power |
95V (120V), 87V (110V), 83V (100V); All voltage setpoints ±5% tolerance
|
Undervoltage Correction |
Voltage boost of 14% applies when input is 95 to 108 (120v), 87 to 99 (110v), 83 to 90 (100v); All voltage setpoints ±5% tolerance
|
Application |
|
Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection
|
AC suppression joule rating |
690
|
Housing material |
Steel
|
Output AC waveform (AC mode) |
Sine wave
|
Output AC waveform (battery mode) |
Pure Sine wave
|
Output Capacity (kVA) |
1.5
|
Output Capacity (kW) |
0.9
|
Output Capacity (VA) |
1500
|
Output Capacity Details |
7.5A @ 120V (default), 8.2A @ 110V, 9A @ 100V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds
|
Operating Elevation |
0-6562 ft. (0-2000 m)
|
Primary UPS Depth (mm) |
335
|
Primary UPS Height (mm) |
259
|
Primary UPS Width (mm) |
173
|
AC Suppression Response Time |
Instantaneous
|
Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch
|
Audible Alarms |
Audible alarm indicates power failure and overload conditions
|
Battery Start Capability |
Cold-start operation supported
|
Cooling Method |
Fan
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
LED Indicators |
Status LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level
|
Frequency Rating Details |
Automatic frequency selection. Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
|
Output Voltage Regulation (Line Mode) |
-13%, + 15%
|
Output Voltage Regulation(Battery Mode) |
+/- 5%
|
Overvoltage Correction |
Voltage reduction of 12% applies when input is 127 to 145 (120v), 116 to 133 (110v), 111 to 121 (100v); All voltage setpoints ±5% tolerance
|
Rechargeable Battery |
Less than 6 hours from 10% to 80% (typical, full load discharge)
|
Recommended Electrical Service |
15A 120V
|
Site Wiring Fault Indication |
Rear panel site wiring fault LED
|
Storage Temperature |
5° to 122°F (-15° to 50°C)
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
Nominal Voltage Details |
120V sinusoidal in line mode and 120V sinusoidal in battery mode
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 95 to 145 (120v), 87 to 133 (110v), 83 to 121 (100v)
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Maximum Input Amps |
10
|
Total Harmonic Distortion |
0.03
|
UPS Input Cord Length (m) |
1.8
|
UPS Power Module Dimensions |
10.2 x 6.8 x 13.2
|
Power Mode Transfer Time |
4-6 milliseconds
|
Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
UPS Input Connection Type |
5-15P
|
Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out)
10/100Base T Ethernet |
High Availability UPS Features |
Automatic voltage regulation (AVR)
Surge/noise protection Auto probe monitoring (requires WEBCARDLXE) Hot swappable batteries Remote management |