SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Network Card Options, USB, DB9 Serial
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART2200VS
|
| UPC |
037332115874
|
| Product Length/Depth |
14.2 in
|
| Product Height |
19.3 in
|
| Product Width |
16.5 in
|
| Product Weight |
52.4 lb
|
| Compliances |
FCC Class A
RoHS |
| Certifications |
UL 1778
NOM CSA certified |
| Topology |
Line-interactive
|
| Package contents |
|
| Input nominal voltage |
120 VAC
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
16A
|
| Battery replacement |
RBC54
|
| Runtime at half load |
19 min
|
| Noise level |
Audible Noise < 47dBA At Front Side 1 Meter
|
| Relative humidity |
0-95% non-condensing
|
| Output Receptacles |
5-15R
5-15/20R |
| Product Features |
Individually Controllable Load Banks
|
| Product Highlights |
To use the Auto Probe feature, this product requires a WEBCARDLX network interface (sold separately) running LX firmware update 15.5.2 or later
NEMA 5-20P input; 2 NEMA 5-15/20R and 7 5-15R outlets USB, RS232, EPO and slot for Network Card Options Front panel status LEDs with load and battery capacity level display 120V nominal output during brownouts to 79V and overvoltages to 147V 2.2kVA / 2200VA line interactive tower UPS system |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
110 / 120V
|
| Network Management Cards |
TLNETCARD
WEBCARDLXE |
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.73
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
7 min. (1600W)
|
| Communication interface |
Contact closure
DB9 Serial Slot for SNMP / Web interface 2 USB and 2 DB9 cables included USB |
| Battery Access |
Battery access door
|
| Dc Voltage |
48
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
2 USB and 2 DB9 cables included
|
| Input Circuit Breakers |
20A
|
| Load Management Receptacles |
Three switchable two-outlet 5-15R load banks
|
| High Voltage Transfer to Battery Power |
147
|
| Low Voltage Transfer to Battery Power |
79
|
| Undervoltage Correction |
Input voltages between 95 and 104 are boosted by 12%
|
| Application |
Large Network
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation
|
| AC suppression joule rating |
480
|
| Housing material |
Polycarbonate
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
2.2
|
| Primary UPS Depth (mm) |
305
|
| Primary UPS Height (mm) |
361
|
| Primary UPS Width (mm) |
234
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure, overload and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
| Output Voltage Regulation (Line Mode) |
-2.25
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Input voltages between 128 and 147 are reduced by 12%
|
| Rechargeable Battery |
Less than 4 hours from 10% to 90% (typical, full load discharge)
|
| Recommended Electrical Service |
20A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)
|
| Nominal Voltage Details |
120v nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 79V to 147V
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
16
|
| UPS Input Cord Length (m) |
2.4
|
| UPS Power Module Dimensions |
14.2 x 9.2 x 12
|
| Power Mode Transfer Time |
2-4 milliseconds
|
| Connected Equipment Insurance |
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-20P
|
| High Availability UPS Features |
Auto probe monitoring and reboot (requires WEBCARDLX)
Hot swappable batteries Surge/noise protection Automatic voltage regulation (AVR) Remote management |