500VA 300W 120V Line-Interactive UPS - 6 NEMA 5-15R Outlets, USB, DB9, Network Card Option, 1U Rack/Tower
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART500RT1U
|
| UPC |
037332119247
|
| Product Length/Depth |
11.26 in
|
| Product Height |
1.73 in
|
| Product Width |
17.32 in
|
| Product Weight |
15.8 lb
|
| Compliances |
ENERGY STAR certified
RoHS |
| Certifications |
CSA certified
NOM UL 1778 |
| Topology |
Line-interactive
|
| Form factor |
Rackmount/Tower
|
| Rack size |
1U
|
| Package contents |
|
| Input nominal voltage |
120 VAC
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
120V
|
| Electric current - max |
10A
|
| Battery replacement |
IMPORTANT BATTERY REPLACEMENT INFORMATION > Use Tripp Lite RBC12V-1U replacement battery for SMART500RT1U models with Series Number AG-03AA listed on the UPS nameplate (sold starting in 2021); For all prior versions of SMART500RT1U, use Tripp Lite RBC62-1U replacement battery; Contact Tripp Lite customer service for additional information
|
| Runtime at half load |
14 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Output Receptacles |
5-15R
|
| Product Features |
Individually Controllable Load Banks
|
| Product Highlights |
Keeps AC power running during blackouts to allow time for file saves and safe shutdown
Optional WEBCARDLXE network interface allows you 24/7 remote access from anywhere 6 NEMA 5-15R outlets power and protect networking, telecom and other sensitive equipment Maintains continuous 120V nominal output during brownouts as low as 90V Protects equipment against blackouts, brownouts, transient surges and line noise |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
120V
|
| Network Management Cards |
WEBCARDLXE
|
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.6
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
3 min. (300W)
|
| Communication interface |
Slot for SNMP / Web interface
EPO (emergency power off) USB (HID enabled) DB9 Serial USB and DB9 serial cables included |
| Battery Access |
Battery access door
|
| Dc Voltage |
12
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Grounding Details |
Back panel grounding lug
|
| Input Circuit Breakers |
10A
|
| Load Management Receptacles |
One switchable single-outlet 5-15R load bank
|
| High Voltage Transfer to Battery Power |
139
|
| Low Voltage Transfer to Battery Power |
90
|
| Undervoltage Correction |
Input voltages between 90 and 105 (±5%) are boosted by 14%
|
| Application |
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation
|
| AC suppression joule rating |
567
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
0.5
|
| Output Capacity Details |
4.2A @ 120V. (LINE MODE) 120% @ 5 minutes; (BATTERY MODE) 120% @ 5 seconds
|
| Operating Elevation |
0-6562 ft. (0-2000 m)
|
| Primary UPS Depth (mm) |
286
|
| Primary UPS Height (mm) |
44
|
| Primary UPS Width (mm) |
440
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch
|
| Audible Alarms |
Audible alarm indicates power-failure, overload and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
| Frequency Rating Details |
Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
|
| Output Voltage Regulation (Line Mode) |
-14%, +16%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Rechargeable Battery |
Less than 12 hours to 90%
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Included Mounting Accessory Description |
Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
| Nominal Voltage Details |
120V sinusoidal in line mode and 120V PWM in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90 (±5%). Input voltage range of 90 to 139
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
10
|
| Minimum Required Rack Depth (cm) |
38.1
|
| Minimum Required Rack Depth (inches) |
15
|
| UPS Input Cord Length (m) |
3.1
|
| UPS Power Module Dimensions |
1.73 x 17.32 x 11.26
|
| Power Mode Transfer Time |
4-6 ms typical ( < 10 ms max)
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
|
| UPS Output Receptacles |
5 UPS outlets, 1 surge-only outlet
|
| High Availability UPS Features |
Remote management
Automatic voltage regulation (AVR) Auto probe monitoring (requires WEBCARDLXE) Surge/noise protection Hot swappable batteries |