SmartPro 120V 500VA 300W Line-Interactive UPS, 1U, WEBCARDLX, USB, DB9, 6 Outlets
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART500RT1UN
|
| UPC |
037332224170
|
| Product Length/Depth |
11.26 in
|
| Product Height |
1 in
|
| Product Width |
17.32 in
|
| Product Weight |
17.6 lb
|
| Compliances |
FCC Class B
RoHS |
| Certifications |
NOM
CSA certified UL 1778 |
| Topology |
Line-interactive
|
| Rack size |
1U
|
| VA rating |
500 VA
|
| Package contents |
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
120V
|
| Battery replacement |
IMPORTANT BATTERY REPLACEMENT INFORMATION > Use Tripp Lite RBC12V-1U replacement battery for SMART500RT1U models with Series Number AG-03AA listed on the UPS nameplate (sold starting in 2021); For all prior versions of SMART500RT1U, use Tripp Lite RBC62-1U replacement battery; Contact Tripp Lite customer service for additional information
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
14 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Input Plug Type |
NEMA 5-15P
|
| Output Receptacles |
5-15R
|
| Product Features |
Individually Controllable Load Banks
|
| Product Highlights |
Keeps AC power running during blackouts to allow time for file saves and safe shutdown
2 year warranty, 3 year with registration. (Worldwide) Note: Registration is required for 3 year warranty. Protects equipment against blackouts, brownouts, overvoltages, surges and line noise Maintains continuous 120V nominal output during brownouts and overvoltages $250,000 Ultimate Lifetime Insurance (U.S., Canada and Puerto Rico only) Included WEBCARDLX network interface allows you 24/7 remote access from anywhere |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
120V
|
| Network Management Cards |
WEBCARDLXE
|
| Network Management Cards Details |
Network management card included
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
3 min. (300W)
|
| Communication interface |
USB (HID enabled)
Slot for SNMP / Web interface EPO (emergency power off) Pre-installed network card DB9 Serial USB and DB9 serial cables included |
| Battery Access |
Battery access door
|
| Dc Voltage |
12
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Grounding Details |
Back panel grounding lug
|
| Input Circuit Breakers |
10A
|
| Load Management Receptacles |
One switchable single-outlet 5-15R load bank
|
| High Voltage Transfer to Battery Power |
139
|
| Low Voltage Transfer to Battery Power |
90
|
| Undervoltage Correction |
Input voltages between 90 and 105 are boosted by 14%
|
| Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
| Application |
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation
|
| AC suppression joule rating |
567
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
0.5
|
| Primary UPS Depth (mm) |
286
|
| Primary UPS Height (mm) |
44
|
| Primary UPS Width (mm) |
440
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch
|
| Audible Alarms |
Audible alarm indicates power-failure, overload and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
| Output Voltage Regulation (Line Mode) |
-14%, +16%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Rechargeable Battery |
Less than 12 hours to 90%
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Form factor |
Rackmount
Tower |
| Included Mounting Accessory Description |
Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations
|
| Network Monitoring Port Description |
Pre-installed WEBCARDLX provides remote monitoring and control via HTML5 web interface, telnet, SSH and SNMP management systems
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Minimum Required Rack Depth (cm) |
38.1
|
| Minimum Required Rack Depth (inches) |
15
|
| UPS Input Cord Length (m) |
3.1
|
| UPS Power Module Dimensions |
1.73 x 17.32 x 11.26
|
| Power Mode Transfer Time |
4 milliseconds (AC to battery); 7 milliseconds (Battery to AC)
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance |
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
|
| UPS Output Receptacles |
5 UPS outlets, 1 surge-only outlet
|
| High Availability UPS Features |
Hot swappable batteries
Surge/noise protection Remote management Auto probe monitoring and reboot (included) Automatic voltage regulation (AVR) |
| Nominal Input Voltage Supported |
120 VAC
|