SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rack/Vertical, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART750RM1UN
|
| UPC |
037332190734
|
| Product Length/Depth |
22.4 in
|
| Product Height |
5.3 in
|
| Product Width |
21.2 in
|
| Product Weight |
30 lb
|
| Compliances |
RoHS
FCC Class A TAA Compliant |
| Certifications |
NOM
UL 1778 CSA certified |
| Topology |
Line-interactive
|
| Rack size |
1U
|
| VA rating |
750 VA
|
| Package contents |
|
| Input cord length |
10 ft
|
| Input nominal voltage |
120 VAC
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
7A
|
| Battery replacement |
RBC64-1U
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
13 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Input Plug Type |
NEMA 5-15P
|
| Output Receptacles |
5-15R
|
| Product Features |
Individually Controllable Load Banks
|
| Product Highlights |
98% line-mode efficiency, 2 switched load banks
120V NEMA 5-15P input, 6 NEMA 5-15R outlets .75kVA / 750VA / 600W line interactive 1U rack/vertical UPS, Sine wave output 0.8 Power Factor, Front panel status LEDs 120V output, Corrects brownouts and overvoltages from 83V to 147V To enable the Auto Probe feature, this product requires LX firmware update 15.5.2 or later to be installed Mounting brackets support 2 and 4 post installation USB, RS232, EPO and Pre-installed WEBCARDLX Network Interface |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| SNMP Compatibility |
SNMP V1, V2c, V3
|
| Nominal Output Voltage |
110 / 120V
|
| Network Management Cards |
WEBCARDLXE
|
| Network Management Cards Details |
Network management card included
|
| Output power factor |
0.8
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
4.9 min. (600W)
|
| Communication interface |
USB
EPO (emergency power off) DB9 Serial Pre-installed network card Slot for SNMP / Web interface USB and DB9 serial cables included |
| Battery Access |
Front panel battery access door
|
| EPO Port |
RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems
|
| Dc Voltage |
24
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Grounding Details |
Back panel grounding lug
|
| Input Circuit Breakers |
15A
|
| Optional Mounting Accessory Notes |
Optional 4POSTRAILKITWM enables installation in 4-port short-depth racks from 14.5 to 23.5 inches (368 to 597mm); Optional 4POSTRAILKIT1U enables installation in 4-post full-depth racks from 20.5 to 36 inches (521 to 914mm)
|
| Load Management Receptacles |
Two switchable single-outlet 5-15R load banks
|
| High Voltage Transfer to Battery Power |
147
|
| Low Voltage Transfer to Battery Power |
83
|
| Undervoltage Correction |
Input voltages between 83 and 107 are boosted by 14%
|
| Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
| Application |
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
|
| AC suppression joule rating |
450
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
0.75
|
| Primary UPS Depth (mm) |
425
|
| Primary UPS Height (mm) |
44
|
| Primary UPS Width (mm) |
445
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure, overload and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status. Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).
|
| Output Voltage Regulation (Line Mode) |
-21%, +8%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Input voltages between 128 and 147 are reduced by 12%
|
| Rechargeable Battery |
3.6 hours maximum from 10% to 90% (typical, full load discharge)
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Included Mounting Accessory Description |
Included mounting brackets provide front-rail installation in 2 or 4 post racks; For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U & 4POSTRAILKITWM
|
| Network Monitoring Port Description |
Includes pre-installed WEBCARDLX Network Management Card
|
| Nominal Voltage Details |
120v nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
7
|
| Minimum Required Rack Depth (cm) |
50.8
|
| Minimum Required Rack Depth (inches) |
20
|
| UPS Power Module Dimensions |
1.75 x 17.5 x 16.75
|
| Power Mode Transfer Time |
5 milliseconds AC to DC; 1 millisecond DC to AC
|
| TAA Compliance |
Yes
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance |
| Optional Accessories |
4 post rackmount full-depth (4POSTRAILKIT1U)
4 post rackmount short-depth (4POSTRAILKITWM) Vertical Mount Enclosures (SRWF5U36, SRWF5U, SRWF10UMOD) |
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
|
| Network Compatibility |
100 Mbps (Fast Ethernet)
|
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Surge/noise protection Remote management Auto probe monitoring and reboot (included) Hot swappable batteries |
| Nominal Input Voltage Supported |
120 VAC
|