SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rack/Vertical, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART750RM1UN
|
| UPC |
037332190734
|
| Product Length/Depth |
22.4 in
|
| Product Height |
5.3 in
|
| Product Width |
21.2 in
|
| Product Weight |
30 lb
|
| Compliances |
RoHS
FCC Class A TAA Compliant |
| Certifications |
NOM
UL 1778 CSA certified |
| Topology |
Line-interactive
|
| Form factor |
Rackmount/Vertical
|
| Rack size |
1U
|
| Package contents |
|
| Input cord length |
10 ft
|
| Input nominal voltage |
120 VAC
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
7A
|
| Battery replacement |
RBC64-1U
|
| Runtime at half load |
13 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Output Receptacles |
5-15R
|
| Product Features |
Individually Controllable Load Banks
|
| Product Highlights |
.75kVA / 750VA / 600W line interactive 1U rack/vertical UPS, Sine wave output
98% line-mode efficiency, 2 switched load banks USB, RS232, EPO and Pre-installed WEBCARDLX Network Interface 0.8 Power Factor, Front panel status LEDs 120V output, Corrects brownouts and overvoltages from 83V to 147V 120V NEMA 5-15P input, 6 NEMA 5-15R outlets Mounting brackets support 2 and 4 post installation To enable the Auto Probe feature, this product requires LX firmware update 15.5.2 or later to be installed |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| SNMP Compatibility |
SNMP V1, V2c, V3
|
| Nominal Output Voltage |
110 / 120V
|
| Network Management Cards |
WEBCARDLXE
|
| Network Management Cards Details |
Network management card included
|
| TAA Compliance |
Yes
|
| Output power factor |
0.8
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
4.9 min. (600W)
|
| Communication interface |
USB
EPO (emergency power off) DB9 Serial Pre-installed network card Slot for SNMP / Web interface USB and DB9 serial cables included |
| Battery Access |
Front panel battery access door
|
| EPO Port |
RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems
|
| Dc Voltage |
24
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Grounding Details |
Back panel grounding lug
|
| Input Circuit Breakers |
15A
|
| Optional Mounting Accessory Notes |
Optional 4POSTRAILKITWM enables installation in 4-port short-depth racks from 14.5 to 23.5 inches (368 to 597mm); Optional 4POSTRAILKIT1U enables installation in 4-post full-depth racks from 20.5 to 36 inches (521 to 914mm)
|
| Load Management Receptacles |
Two switchable single-outlet 5-15R load banks
|
| High Voltage Transfer to Battery Power |
147
|
| Low Voltage Transfer to Battery Power |
83
|
| Undervoltage Correction |
Input voltages between 83 and 107 are boosted by 14%
|
| Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
| Application |
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
|
| AC suppression joule rating |
450
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
0.75
|
| Primary UPS Depth (mm) |
425
|
| Primary UPS Height (mm) |
44
|
| Primary UPS Width (mm) |
445
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure, overload and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status. Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).
|
| Output Voltage Regulation (Line Mode) |
-21%, +8%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Input voltages between 128 and 147 are reduced by 12%
|
| Rechargeable Battery |
3.6 hours maximum from 10% to 90% (typical, full load discharge)
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Included Mounting Accessory Description |
Included mounting brackets provide front-rail installation in 2 or 4 post racks; For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U & 4POSTRAILKITWM
|
| Network Monitoring Port Description |
Includes pre-installed WEBCARDLX Network Management Card
|
| Nominal Voltage Details |
120v nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
7
|
| Minimum Required Rack Depth (cm) |
50.8
|
| Minimum Required Rack Depth (inches) |
20
|
| UPS Power Module Dimensions |
1.75 x 17.5 x 16.75
|
| Power Mode Transfer Time |
5 milliseconds AC to DC; 1 millisecond DC to AC
|
| TAA Compliance |
Yes
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
| Optional Accessories |
4 post rackmount full-depth (4POSTRAILKIT1U)
4 post rackmount short-depth (4POSTRAILKITWM) Vertical Mount Enclosures (SRWF5U36, SRWF5U, SRWF10UMOD) |
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
|
| Network Compatibility |
100 Mbps (Fast Ethernet)
|
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Surge/noise protection Remote management Auto probe monitoring and reboot (included) Hot swappable batteries |