SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, Network Card Options, USB, DB9 Serial
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMART750SLT
|
| UPC |
037332124395
|
| Product Length/Depth |
18.1 in
|
| Product Height |
13.9 in
|
| Product Width |
9.6 in
|
| Product Weight |
34.1 lb
|
| Compliances |
RoHS
|
| Certifications |
UL 1778
CSA certified NOM |
| Topology |
Line-interactive
|
| Form factor |
Tower
|
| Package contents |
|
| Input nominal voltage |
120V default (100/110/120V)
|
| Nominal frequency |
50/60 Hz
|
| Input frequency range |
50/60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
100/110/120V
|
| Electric current - max |
12A
|
| Battery replacement |
RBC24-SLT
|
| Runtime at half load |
17 min
|
| Noise level |
Audible Noise < 50 dBA at Front Side 1 Meter
|
| Relative humidity |
0-95% non-condensing
|
| Output Receptacles |
5-15R
|
| Product Features |
Individually Controllable Load Banks
|
| Product Highlights |
Designed for commercial applications; see product description for home-use recommendations
Detailed status LEDs; Single line TEL / DSL surge suppression NEMA 5-15P input; 8 NEMA 5-15R outlets 100/110/120V nominal output during brownouts and overvoltages USB, RS-232 and slot for Network Management Card options |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
100/110/120V
|
| Network Management Cards |
WEBCARDLXE
RELAYIOCARD |
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.7
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
6.5 min. (500W)
|
| Communication interface |
USB
Slot for SNMP / Web interface DB9 Serial USB and DB9 serial cables included |
| Battery Access |
Battery access door
|
| Dc Voltage |
24
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| High Voltage Transfer to Battery Power |
145V (120V), 133V (110V), 121V (100V); Voltage setpoints ±5% tolerance
|
| Low Voltage Transfer to Battery Power |
95V (120V), 87V (110V), 83V (100V); Voltage setpoints ±5% tolerance
|
| Undervoltage Correction |
Voltage boost of 17% applies when input is 96 to 108 (120v), 87 to 99 (110v), 83 to 90 (100v); Voltage setpoints ±5% tolerance
|
| Application |
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection
|
| AC suppression joule rating |
480
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
0.75
|
| Output Capacity (kW) |
0.5
|
| Output Capacity (VA) |
750
|
| Primary UPS Depth (mm) |
337
|
| Primary UPS Height (mm) |
259
|
| Primary UPS Width (mm) |
173
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch
|
| Audible Alarms |
Audible alarm indicates power failure and overload conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level
|
| Frequency Rating Details |
Automatic frequency selection
|
| Output Voltage Regulation (Line Mode) |
-13%, +15%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Voltage reduction of 12% applies when input is 127 to 145 (120v), 116 to 133 (110v), 106 to 121 (100v)
|
| Rechargeable Battery |
Less than 8 hours from 10% to 90% (typical, full load discharge)
|
| Recommended Electrical Service |
15A 120V
|
| Site Wiring Fault Indication |
Rear panel site wiring fault LED
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
| Nominal Voltage Details |
120V default (voltage selection via back panel switches)
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 (120v), 87 to 133 (110v), 83 to 121 (100v)
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
12
|
| UPS Input Cord Length (m) |
1.8
|
| UPS Power Module Dimensions |
10.2 x 6.8 x 13.25
|
| Power Mode Transfer Time |
4-8 milliseconds
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
|
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
| UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out)
10/100Base T Ethernet |
| UPS Output Receptacles |
4 UPS outlets, 4 surge-only outlets
|
| High Availability UPS Features |
Auto probe monitoring (requires WEBCARDLXE)
Hot swappable batteries Remote management Surge/noise protection Automatic voltage regulation (AVR) |