Download documento () de 20

266005
Model code: PN2-160

Eaton Moeller series NZM - Molded Case Circuit Breaker. Switch-disconnector 3p, 160A, 2

General specifications

Product Name
Eaton Moeller series NZM switch-disconnector
Catalog Number
266005
EAN
4015082660055
Product Length/Depth
142 mm
Product Height
185 mm
Product Width
105 mm
Product Weight
1.895 kg
Compliances
RoHS conform
Certifications
IEC/EN 60947
IEC
Model Code
PN2-160

Dados técnicos - elétricos

Voltage rating
690 V - 690 V
Rated operating voltage (Ue) at AC - max
690 V
Rated insulation voltage (Ui)
690 V
Rated impulse withstand voltage (Uimp) at auxiliary contacts
6000 V
Rated impulse withstand voltage (Uimp) at main contacts
8000 V
Rated operational current
160 A (415 V AC-22/23A, making and breaking capacity)
160 A (690 V AC-22/23A, making and breaking capacity)
Rated conditional short-circuit current with back-up fuse
80 kA at 690 V
PN2(N2)-160…250: 250 AgGgL
100 kA at 400/415 V
Rated conditional short-circuit current with downstream fuse
80 kA at 690 V
100 kA at 400/415 V
PN2(N2)-160…250: 250 AgGgL
Rated short-time withstand current (Icw)
3.5 kA
Rated short-time withstand current (t = 0.3 s)
3.5 kA
Rated short-time withstand current (t = 1 s)
3.5 kA
Amperage Rating
160 A
Rated operating frequency
50 Hz
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
5.5 kA
Rated operating power at AC-23, 400 V
90 kW
Short-circuit protective device fuses - max
250 A gL
Electrical connection type of main circuit
Screw connection
Isolation
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts)
Number of operations per hour - max
120
Handle type
Rocker lever
Overvoltage category
III
Pollution degree
3
Lifespan, electrical
7500 operations at 690 V AC-1
10000 operations at 415 V AC-1
5000 operations at 690 V AC-3
10000 operations at 400 V AC-1
7500 operations at 400 V AC-3
7500 operations at 415 V AC-3
Direction of incoming supply
As required

Dados técnicos - comunicação

Rated impulse withstand voltage (Uimp) at auxiliary contacts
6000 V
Rated impulse withstand voltage (Uimp) at main contacts
8000 V
Rated operational current
160 A (415 V AC-22/23A, making and breaking capacity)
160 A (690 V AC-22/23A, making and breaking capacity)
Rated conditional short-circuit current with back-up fuse
80 kA at 690 V
PN2(N2)-160…250: 250 AgGgL
100 kA at 400/415 V
Rated conditional short-circuit current with downstream fuse
80 kA at 690 V
100 kA at 400/415 V
PN2(N2)-160…250: 250 AgGgL
Rated short-time withstand current (Icw)
3.5 kA
Rated short-time withstand current (t = 0.3 s)
3.5 kA
Rated short-time withstand current (t = 1 s)
3.5 kA
Amperage Rating
160 A
Rated operating frequency
50 Hz
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
5.5 kA
Rated operating power at AC-23, 400 V
90 kW
Short-circuit protective device fuses - max
250 A gL
Electrical connection type of main circuit
Screw connection
Isolation
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts)
Number of operations per hour - max
120
Handle type
Rocker lever
Overvoltage category
III
Pollution degree
3
Lifespan, electrical
7500 operations at 690 V AC-1
10000 operations at 415 V AC-1
5000 operations at 690 V AC-3
10000 operations at 400 V AC-1
7500 operations at 400 V AC-3
7500 operations at 415 V AC-3
Direction of incoming supply
As required

Dados técnicos - mecânicos

Mounting Method
Fixed
Built-in device fixed built-in technique
Distribution board installation
Intermediate mounting
Ground mounting
Degree of protection
IP20 (basic protection type, in the area of the HMI devices)
Other
Degree of protection (IP), front side
IP20
IP66 (with door coupling rotary handle)
IP40 (with insulating surround)
Degree of protection (terminations)
IP10 (tunnel terminal)
IP00 (terminations, phase isolator and band terminal)
Protection against direct contact
Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
Shock resistance
20 g (half-sinusoidal shock 20 ms)
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Number of switches
1
Handle color
Black
Switch positions
I, 0
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Lifespan, mechanical
20000 operations

Exportar as especificações do produto

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Autenticar produto

Introduza o seu número de série de 16–17 dígitos
O número de série que introduziu não deve conter caracteres especiais. O número de série que introduziu está incorreto; deve ter 16 ou 17 dígitos. O número de série que introduziu não foi encontrado. Tente novamente ou comunicar este problema para obter assistência adicional. O número de série que introduziu não corresponde ao produto. Verifique o número de série do seu produto e tente novamente. Clique aqui para navegar até à página do produto correspondente ao número de série que introduziu O número de série é considerado SUSPEITO pela Eaton, tente novamente ou comunicar este problema para obter assistência adicional.
Número de série
Reset O número de série é considerado SUSPEITO pela Eaton, tente novamente ou comunicar este problema para obter assistência adicional. O número de série não é reconhecido pela Eaton e é inválido. Utilize este formulário para comunicar este problema para obter assistência adicional.
Introduza o código de autenticação de 6 dígitos
O produto que introduziu é suspeito! Tente novamente ou comunicar este problema para obter assistência adicional. O código de autenticação que introduziu não corresponde aos nossos registos para este número de série. Tente novamente ou comunicar este problema para obter assistência adicional. Código de autenticação inválido. O comprimento deve ser de 6 caracteres comunicar este problema para obter assistência adicional. O código de autenticação é obrigatório comunicar este problema para obter assistência adicional.
Conclua o desafio Captcha antes de autenticar.
Contacte-nos para comunicar problema
x
Comunicar um problema
Introduza o seu nome completo.
x
Obrigado, o seu problema foi submetido. A nossa equipa de produto entrará em contacto consigo em breve.
Nota: Se existirem ficheiro(s) em falta na pasta .zip transferida, significa que o tipo de ficheiro não é compatível com a transferência de vários ficheiros em simultâneo.