Download
Eaton Moeller® series PKE65 Motor-protective circuit-breaker, Complete device with standard knob, Electronic, 8 - 32 A, 32 A, With overload release
Product Name |
Eaton Moeller® series PKE System-protective circuit-breaker
|
Catalog Number |
138517
|
Model Code |
PKE65/XTUW-32
|
EAN |
4015081352968
|
Product Length/Depth |
187 mm
|
Product Height |
162 mm
|
Product Width |
55 mm
|
Product Weight |
1.427 kg
|
Certifications |
CSA Class No.: 3211-05
UL File No.: E36332 VDE 0660 IEC/EN 60947-4-1 CSA File No.: 165628 IEC/EN 60947 CE UL Category Control No.: NLRV CSA-C22.2 No. 60947-4-1-14 CSA UL UL 60947-4-1 |
Catalog Notes |
This is a product for Environment A (Industrial). In environment B (household) this device may cause undesirable radio interference. In this case the user may be obliged to take appropriate measures.
|
Global Catalog |
138517
|
Features |
Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE 0660 Part 102)
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Standard knob
|
Operating frequency |
60 Operations/h
|
Pollution degree |
3
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Actuator type |
Turn button
|
Adjustment range undelayed short-circuit release - max |
496 A
|
Adjustment range undelayed short-circuit release - min |
496 A
|
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature (enclosed) - max |
40 °C
|
Ambient operating temperature (enclosed) - min |
-25 °C
|
Ambient storage temperature - max |
80 °C
|
Ambient storage temperature - min |
-40 °C
|
Assigned motor power at 115/120 V, 60 Hz, 1-phase |
2 HP
|
Assigned motor power at 200/208 V, 60 Hz, 3-phase |
7.5 HP
|
Assigned motor power at 230/240 V, 60 Hz, 1-phase |
3 HP
|
Assigned motor power at 230/240 V, 60 Hz, 3-phase |
7.5 HP
|
Assigned motor power at 460/480 V, 60 Hz, 3-phase |
20 HP
|
Assigned motor power at 575/600 V, 60 Hz, 3-phase |
25 HP
|
Equipment heat dissipation, current-dependent Pvid |
5.2 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
1.7 W
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Altitude |
Max. 2000 m
|
Device construction |
Built-in device fixed built-in technique
|
Connection |
Screw terminals
|
Electrical connection type of main circuit |
Screw connection
|
Current flow times - min |
900 (Class 15) AC-4 cycle operation, Main conducting paths
1000 (Class 20) AC-4 cycle operation, Main conducting paths For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. 500 (Class 5) AC-4 cycle operation, Main conducting paths Note: Going below the minimum current flow time can cause overheating of the load (motor). 700 (Class 10) AC-4 cycle operation, Main conducting paths |
Lifespan, mechanical |
30,000 Operations (Main conducting paths)
|
Overvoltage category |
III
|
Cut-out periods - min |
≤ 500 ms, main conducting paths, AC-4 cycle operation
|
Degree of protection |
Terminals: IP00
IP20 |
Number of poles |
Three-pole
|
Lifespan, electrical |
50,000 operations (at 400V, AC-3)
|
Shock resistance |
15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
|
Functions |
Overload release
Motor protection Motor protection for heavy starting duty |
Terminal capacity (solid/stranded AWG) |
14 - 2
|
Switching capacity |
32 A, General use UL/CSA
32 A, AC-3 up to 690 V |
Overload release current setting - max |
32 A
|
Overload release current setting - min |
8 A
|
Rated frequency - max |
60 Hz
|
Rated frequency - min |
50 Hz
|
Rated operational voltage (Ue) - max |
690 V
|
Rated operational voltage (Ue) - min |
690 V
|
Rated operational current for specified heat dissipation (In) |
32 A
|
Rated operational power at AC-3, 220/230 V, 50 Hz |
7.5 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
15 kW
|
Rated uninterrupted current (Iu) |
32 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
Stripping length (main cable) |
14 mm
|
Product category |
Motor protective circuit breaker
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
Rated operational power at AC-3, 440 V, 50 Hz |
15 kW
|
Rated operational power at AC-3, 500 V, 50 Hz |
18.5 kW
|
Rated operational power at AC-3, 690 V, 50 Hz |
30 kW
|
Rated short-circuit breaking capacity Icu at 400 V AC |
50 kA
|
Rated short-circuit breaking capacity Ics at 400 V AC |
12 kA
|
Rated short-circuit breaking capacity Icu at 440 V AC |
45 kA
|
Rated short-circuit breaking capacity Ics at 440 V AC |
11 kA
|
Rated short-circuit breaking capacity Icu at 500 V AC |
15 kA
|
Rated short-circuit breaking capacity Ics at 500 V AC |
3 kA
|
Rated short-circuit breaking capacity Icu at 690 V AC |
5 kA
|
Rated short-circuit breaking capacity Ics at 690 V AC |
1 kA
|
Suitable for |
Also motors with efficiency class IE3
|
Short-circuit release |
± 20% tolerance, Trip blocks
Delayed approx. 60 ms, Trip blocks Basic device fixed 15.5 x Iu, Trip Blocks Trip block fixed 15.5 x Ir |
Terminal capacity (solid) |
1 x (0.75 - 16) mm²
2 x (0.75 - 16) mm² |
Rated operational current (Ie) |
32 A
|
Temperature compensation |
-5 - 40 °C to IEC/EN 60947, VDE 0660
-25 - 55 °C, Operating range |
Short-circuit current rating (group protection) |
200 A, Class J, 600 V High Fault, max. Fuse, SCCR (UL/CSA)
100 kA, 600 V High Fault, Fuse, SCCR (UL/CSA) |
Tightening torque |
1 Nm, Screw terminals, Control circuit cables
3.3 Nm, Screw terminals, Main cable |
Switch off technique |
Electronic
|
Terminal capacity (flexible with ferrule) |
2 x (0.75 - 25) mm², ferrule to DIN 46228
1 x (0.75 - 35) mm², ferrule to DIN 46228 |
Power loss |
5.2 W
|
Resistance per pole |
2.1 mΩ
|