Download document () of 20

153152
Model code: ESR5-NOS-31-230VAC

Eaton ESR5 Safety relay emergency stop/protective door, 230VAC, 3 enabling paths ESR5-NOS-31-230VAC

General specifications

Product Name
Eaton ESR5 Safety relay
Catalog Number
153152
Model Code
ESR5-NOS-31-230VAC
EAN
4015081497485
Product Length/Depth
114.5 mm
Product Height
99 mm
Product Width
22.5 mm
Product Weight
0.177 kg
Certifications
UL File No.: E29184
2014/30/EU
CSA-C22.2 No. 14-95
UL 508
EN 50156-1
UL report applies to both US and Canada
UL Category Control No.: NKCR; NKCR7
CE
Certified by UL for use in Canada
CSA Class No.: 3211-83; 3211-03
EN 50178
IEC/EN 60204
UL
EN ISO 13849-1
IEC 61508, Parts 1-7
IEC 62061
Machines 2006/42/EG
Global Catalog
153152

Product specifications

Type
  • Emergency stop category 0; emergency switching off
  • Protective door
Mounting method
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible
Operating temperature - max
55 °C
Operating temperature - min
-25 °C
Features
6 kV between A1-A2 / logic / enable and signal current paths
Reinforced insulation
3 Non-delayed enable current paths
Safe insulation
Basic insulation
Automatically/manually monitored start
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Electric connection type
Screw connection
Fitted with:
Feedback circuit
Approval for TÜV
Start input
Approval according to UL
Detachable clamps
Pollution degree
2
Climatic proofing
Dry heat to IEC 60068-2-2
Cold to EN 60068-2-1
Damp heat, constant, to IEC 60068-2-3
Rated impulse withstand voltage (Uimp)
4000 V AC
Air pressure
795 - 1080 hPa (operation)
Altitude
Max. 2000 m
Category (EN 954-1)
1
Degree of protection
Terminals: IP20
Enclosure: IP20
IP20
Installation location: ≥ IP54
Environmental conditions
Condensation: Non-condensing
Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 14-95
Number of inputs
1-channel
Functions
1-channel
Safety performance level (EN ISO 13849-1)
Level c
Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-20 °C
Ambient storage temperature - max
85 °C
Ambient storage temperature - min
-40 °C
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Number of outputs (safety related, delayed) with contact
0
Number of outputs (safety related, delayed, semiconductors)
0
Number of outputs (safety related, undelayed) with contact
3
Number of outputs (safety related, undelayed, semiconductors)
0
Number of outputs (signaling function, delayed) with contact
0
Number of outputs (signaling function, delayed, semiconductors)
0
Number of outputs (signaling function, undelayed) with contact
1
Number of outputs (signaling function, undelayed, semiconductors)
0
Rated control supply voltage (Us) at AC, 50 Hz - max
230 V
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
230 V
Screwdriver size
2, Terminal screw, Pozidriv screwdriver
0.6 x 3.5 mm, Terminal screws
Voltage type
AC
Connection type
M3 screw terminals
Mounting position
As required
Breaking power
88 W max., resistive load (τ = 0 ms), at 220 V DC
40 W max., inductive load (τ = 40 ms), at 48 V DC
2000 VA, max., resistive load (τ = 0 ms), at 250 V AC
48 W max., inductive load (τ = 40 ms), at 24 V DC
35 W max., inductive load (τ = 40 ms), at 110 V DC
144 W max., resistive load (τ = 0 ms), at 24 V DC
33 W max., inductive load (τ = 40 ms), at 220 V DC
230 W max., resistive load (τ = 0 ms), at 48 V DC
68 W max., resistive load (τ = 0 ms), at 110 V DC
Overvoltage category
III
Short-circuit protection rating
10A gL/gG, NEOZED (N/O), Output fuse, External, Output data
6A gL/gG, NEOZED (N/C), Output fuse, External, Output data
Duty factor
100 %
Emitted interference
According to EN 61000-6-4
Current consumption
22 mA, DC
Material
Contacts: silver tin oxide, gold plated (AgSnO2, 0.2 µm Au)
Enclosure: Polyamide (PA), not reinforced
Interference immunity
According to EN 61000-6-2
Tightening torque
0.6 Nm, Screw terminals
Mounting width
22.5 mm
Suitable for
Monitoring of emergency-stop circuits
Module used to safely interrupt electrical circuits
Safety relay for monitoring emergency stop and protective door switch
Monitoring of position switches
Relative humidity
< 75 %
LED indicator
Status indication of SmartWire-DT network: Green LED
Pick-up time
50 ms typ. (K1, K2 - for UN manual operation)
300 ms typ. (at Uₑ in automatic mode)
330 ms typ. (if actuated via A1 or S11/S12)
300 ms typ. (K1, K2 - for UN automatic mode)
50 ms typ. (at Uₑ in manual mode)
Lifespan, mechanical
10,000,000 Operations
Input
∞ ms, Simultaneity for inputs 1/2
Recovery time
1000 ms
Inrush current
0.1 - 6 A
Model
Basic device
Safety type (IEC 61496-1)
None
Vibration resistance
10 - 150 Hz, Amplitude: 0.15 mm, Acceleration: 2 g, (IEC/EN 60068-2-6)
Safety parameter (EN ISO 13849-1)
PL c, Performance level
300,000 switching cycles, B10d
Cat. 1, Category
Terminal capacity
24 - 12 AWG, solid or stranded
2 x (0.2 – 1) mm², solid
2 x (0.25 – 1) mm², flexible with ferrule
1 x (0.2 – 2.5) mm², solid
1 x (0.25 – 2.5) mm², flexible with ferrule
Rated control supply voltage (Us) at AC, 60 Hz - min
20.4 V
Rated control supply voltage (Us) at DC - max
0 V
Rated control supply voltage (Us) at DC - min
0 V
Rated insulation voltage (Ui)
250 V
Rated operational current for specified heat dissipation (In)
0 A
Release-delay - max
0 s
Release-delay - min
0 s
Static heat dissipation, non-current-dependent Pvs
5.43 W
Stripping length (main cable)
7 mm
Switching voltage
250 V
Product category
Electronic safety relays
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
SIL (IEC 61508)
1
Permissible total cable resistance
50 Ω (input and starting circuits for UN)
Power loss
Normally 5.43 W
Quadratic summation current
72 A² (ITH² = I1² + I2² + I3²)
Rated operational voltage
230 V AC (power supply)
230 V AC
Approx. 24 V DC at input, starting and feedback circuit
Reset time
20 ms (on actuation via S11/S12)
Normally 150 ms (on actuation via A1)
Safety parameter (IEC 62061)
Cat. 1, Category
SILCL 1, Safety integrity level claim limit
SIL 1, Safety integrity level, In accordance with IEC 61508
2.42 x 10-10, PFHd, Probability of failure per hour
Uninterrupted current
5 A N/C, Limiting continuous current
6 A N/O, Limiting continuous current
Short-circuit protection
Fuse 10 A gL/gG (Enable current paths), For output circuits, External
Fuse 6 A gL/gG (Signal current paths), For output circuits, External
Stop category (IEC 60204)
0
Switching capacity
0.01 W
In accordance with IEC 60947-5-1, Outputs
Switching frequency
Max. 0.5 Hz, Input data
Power consumption
5.43 W
Control voltage 1 - min
230 V
Control voltage 1 - max
230 V
Control voltage 2 - min
230 V
Control voltage 2 - max
230 V
Control voltage 1 type
AC
Control voltage 2 type
AC
Voltage type of supply voltage
AC
Voltage type of operating voltage
AC
Rated switch current
6 A
Supply voltage at AC, 50 Hz - min
230 V
Supply voltage at AC, 50 Hz - max
230 V
Supply voltage at AC, 60 Hz - min
230 V
Supply voltage at AC, 60 Hz - max
230 V
Supply voltage at DC - min
0 V
Supply voltage at DC - max
0 V
Operating voltage at AC, 50 Hz - min
230 V
Operating voltage at AC, 50 Hz - max
230 V
Operating voltage at AC, 60 Hz - min
230 V
Operating voltage at AC, 60 Hz - max
230 V
Operating voltage at DC - min
0 V
Operating voltage at DC - max
0 V

Export product specification