Eaton Moeller® series DILMP Contactor, 4 pole, 22 A, 120 V DC, DC operation
Product Name |
Eaton Moeller® series DILMP 4-pole contactor
|
Catalog Number |
158235
|
Model Code |
DILMP20(120VDC)
|
EAN |
4015081548231
|
Product Length/Depth |
75 mm
|
Product Height |
68 mm
|
Product Width |
45 mm
|
Product Weight |
0.29 kg
|
Certifications |
CSA Class No.: 2411-03, 3211-04
CSA File No.: 012528 CE UL 60947-4-1 UL Category Control No.: NLDX UL CSA-C22.2 No. 60947-4-1-14 IEC/EN 60947-4-1 UL File No.: E29096 VDE 0660 CSA IEC/EN 60947 |
Catalog Notes |
Also tested according to AC-3e.
|
Global Catalog |
158235
|
Number of poles |
Four-pole
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Operating frequency |
5000 mechanical Operations/h (DC operated)
5000 mechanical Operations/h (AC operated) |
Pollution degree |
3
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Connection to SmartWire-DT |
No
|
Rated impulse withstand voltage (Uimp) |
8000 V AC
|
Utilization category |
AC-3: Normal AC induction motors: starting, switch off during running
AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
Connection |
Screw terminals
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature (enclosed) - max |
40 °C
|
Ambient operating temperature (enclosed) - min |
-25 °C
|
Ambient storage temperature - max |
80 °C
|
Ambient storage temperature - min |
-40 °C
|
Conventional thermal current Ith (1-pole, enclosed) |
54 A
|
Conventional thermal current Ith (3-pole, enclosed) |
18 A
|
Conventional thermal current Ith at 55°C (3-pole, open) |
20.5 A
|
Conventional thermal current Ith of main contacts (1-pole, open) |
60 A
|
Equipment heat dissipation, current-dependent Pvid |
5.1 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
1.7 W
|
Switching time (DC operated, make contacts, closing delay) - max |
31 ms
|
Switching time (DC operated, make contacts, opening delay) - max |
12 ms
|
Application |
Contactors for 4 pole electric consumers
|
Product category |
Contactors
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
Arcing time |
10 ms
|
Electrical connection type of main circuit |
Screw connection
|
Screwdriver size |
2, Terminal screw, Pozidriv screwdriver
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver |
Voltage type |
DC
|
Degree of protection |
IP20
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Number of contacts (normally closed) as main contact |
0
|
Number of main contacts (normally open contact) |
4
|
Power consumption (pick-up) at DC |
4.5 W
|
Power consumption (sealing) at DC |
4.5 W
|
Rated breaking capacity at 220/230 V |
120 A
|
Rated breaking capacity at 380/400 V |
120 A
|
Rated breaking capacity at 500 V |
100 A
|
Rated breaking capacity at 660/690 V |
70 A
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Drop-out voltage |
0.2 - 0.6 x UC, DC operated
|
Overvoltage category |
III
|
Duty factor |
100 %
|
Interference immunity |
According to EN 60947-1
|
Lifespan, mechanical |
10,000,000 Operations (DC operated)
10,000,000 Operations (AC operated) |
Pick-up voltage |
0.8 - 1.1 V AC/DC x Us
0.8 - 1.1 V DC x Uc |
Safe isolation |
400 V AC, Between the contacts, According to EN 61140
400 V AC, Between coil and contacts, According to EN 61140 |
Residual current |
1 mA (with actuation of A1 - A2 by the electronics with "0" signal)
|
Screw size |
M3.5, Terminal screw
|
Terminal capacity (flexible with ferrule) |
2 x (0.75 - 2.5) mm²
1 x (0.75 - 2.5) mm² |
Shock resistance |
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
Terminal capacity (solid) |
2 x (0.75 - 2.5) mm²
1 x (0.75 - 4) mm² |
Terminal capacity (solid/stranded AWG) |
18 - 14
|
Switching capacity (main contacts, general use) |
20 A, Maximum motor rating (UL/CSA)
|
Tightening torque |
1.2 Nm, Screw terminals
|
Rated control supply voltage (Us) at DC - max |
120 V
|
Rated control supply voltage (Us) at DC - min |
120 V
|
Rated insulation voltage (Ui) |
690 V
|
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) |
144 A
|
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
22 A
|
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V |
12 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
12 A
|
Rated operational current (Ie) at AC-3, 440 V |
12 A
|
Rated operational current (Ie) at AC-3, 500 V |
10 A
|
Rated operational current (Ie) at AC-3, 660 V, 690 V |
7 A
|
Rated operational current (Ie) at AC-4, 400 V |
10 A
|
Rated operational current (Ie) at DC-1, 110 V |
22 A
|
Rated operational current (Ie) at DC-1, 220 V |
6 A
|
Rated operational current (Ie) at DC-1, 60 V |
22 A
|
Rated operational current for specified heat dissipation (In) |
22 A
|
Rated operational power at AC-1, 220/230 V, 50 Hz |
8 kW
|
Rated operational power at AC-1, 240 V, 50 Hz |
9 kW
|
Rated operational power at AC-1, 380/400 V, 50 Hz |
14 kW
|
Rated operational power at AC-1, 415 V, 50 Hz |
15 kW
|
Rated operational power at AC-1, 440 V, 50 Hz |
16 kW
|
Rated operational power at AC-1, 500 V, 50 Hz |
18 kW
|
Rated operational power at AC-1, 690 V, 50 Hz |
24 kW
|
Rated operational power at AC-3, 240 V, 50 Hz |
4 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
5.5 kW
|
Rated operational power at AC-3, 415 V, 50 Hz |
7 kW
|
Rated operational power at AC-4, 380/400 V, 50 Hz |
4.5 kW
|
Rated operational power (NEMA) |
0 kW
|
Rated operational voltage (Ue) at AC - max |
690 V
|
Resistance per pole |
3.5 mΩ
|
Static heat dissipation, non-current-dependent Pvs |
4.5 W
|
Stripping length (control circuit cable) |
10 mm
|
Stripping length (main cable) |
10 mm
|
Short-circuit current rating (basic rating) |
45 A, max. Fuse, SCCR (UL/CSA)
60 A, max. CB, SCCR (UL/CSA) 5 kA, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 480 V) |
30 kA, Fuse, SCCR (UL/CSA)
25 A, Class RK5, max. Fuse, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 600 V) |
30 kA, Fuse, SCCR (UL/CSA)
25 A, Class RK5, max. Fuse, SCCR (UL/CSA) |
Short-circuit protection rating (type 1 coordination) at 400 V |
35 A gG/gL
|
Short-circuit protection rating (type 1 coordination) at 690 V |
25 A gG/gL
|
Short-circuit protection rating (type 2 coordination) at 400 V |
20 A gG/gL
|
Short-circuit protection rating (type 2 coordination) at 690 V |
20 A gG/gL
|
Special purpose rating of ballast electrical discharge lamps |
20 A (600V 60Hz 3phase, 347V 60Hz 1phase)
20 A (480V 60Hz 3phase, 277V 60Hz 1phase) |
Special purpose rating of elevator control |
5 HP, 600 V 60 Hz 3-ph, (UL/CSA)
6.1 A, 600 V 60 Hz 3-ph, (UL/CSA) |
Special purpose rating of refrigeration control (CSA only) |
10 A, FLA 480 V 60 Hz 3phase; (CSA)
10 A, FLA 600 V 60 Hz 3phase; (CSA) 60 A, LRA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 600 V 60 Hz 3phase; (CSA) |
Special purpose rating of resistance air heating |
20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
20 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) |
Special purpose rating of tungsten incandescent lamps |
14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) |
Conventional thermal current Ith at 40°C (3-pole, open) |
22 A
|
Conventional thermal current Ith at 50°C (3-pole, open) |
21 A
|
Conventional thermal current Ith at 60°C (3-pole, open) |
20 A
|
Rated operational power at AC-3, 440 V, 50 Hz |
7.5 kW
|
Rated operational power at AC-3, 500 V, 50 Hz |
7 kW
|
Rated operational power at AC-3, 690 V, 50 Hz |
6.5 kW
|
Actuating voltage |
120 V DC
|
Altitude |
Max. 2000 m
|
Operating voltage at AC, 50 Hz - min |
24 V
|
Operating voltage at AC, 50 Hz - max |
690 V
|
Operating voltage at AC, 60 Hz - min |
24 V
|
Operating voltage at AC, 60 Hz - max |
690 V
|