Eaton ESR5 Safety relay emergency stop/protective door/light curtain monitoring with wide range input, 24 V-230 VDC/AC
Product Name |
Eaton ESR5 Safety relay
|
Catalog Number |
191796
|
Model Code |
ESR5-NO-31-UC
|
EAN |
4015081923151
|
Product Length/Depth |
114.5 mm
|
Product Height |
113 mm
|
Product Width |
22.5 mm
|
Product Weight |
0.17 kg
|
Certifications |
Certified by UL for use in Canada
CSA-C22.2 No. 14-95 IEC/EN 60947-5-1 UL 508 2014/30/EU CE IEC 62061 UL report applies to both US and Canada EN 50156-1 EN ISO 13849-1 UL UL File No.: E29184 IEC 61508, Parts 1-7 Machines 2006/42/EG |
Global Catalog |
191796
|
Type |
|
Mounting method |
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible |
Operating temperature - max |
55 °C
|
Operating temperature - min |
-40 °C
|
Features |
Start button monitoring
4 kV basic insulation between all current paths and enclosure 4 kV basic insulation between 23/24 and 33/34 enable signal current paths and 41/42 signaling current path Manual start 3 Non-delayed enable current paths Safe insulation Automatic start 6 kV reinforced insulation between all other current paths |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Electric connection type |
Screw connection
|
Fitted with: |
Detachable clamps
Approval according to UL Start input Feedback circuit |
Pollution degree |
2
|
Air pressure |
795 - 1080 hPa (operation)
|
Altitude |
Max. 2000 m
|
Category (EN 954-1) |
None
|
Degree of protection |
Terminals: IP20
Installation location: ≥ IP54 IP20 Enclosure: IP20 |
Environmental conditions |
Condensation: Non-condensing
|
Number of inputs |
One- and two-channel
|
Functions |
2-channel
1-channel |
Safety performance level (EN ISO 13849-1) |
Level e
|
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-40 °C
|
Ambient storage temperature - max |
85 °C
|
Ambient storage temperature - min |
-40 °C
|
Equipment heat dissipation, current-dependent Pvid |
2.7 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Lifetime |
240 month
|
Number of outputs (safety related, delayed) with contact |
0
|
Number of outputs (safety related, delayed, semiconductors) |
0
|
Number of outputs (safety related, undelayed) with contact |
0
|
Number of outputs (safety related, undelayed, semiconductors) |
0
|
Number of outputs (signaling function, delayed) with contact |
0
|
Number of outputs (signaling function, delayed, semiconductors) |
0
|
Number of outputs (signaling function, undelayed) with contact |
0
|
Number of outputs (signaling function, undelayed, semiconductors) |
0
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
230 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
230 V
|
Voltage type |
AC/DC
|
Connection type |
M3 screw terminals
|
Mounting position |
As required
|
Breaking power |
40 W max., inductive load (τ = 40 ms), at 48 V DC
35 W max., inductive load (τ = 40 ms), at 110 V DC 1500 VA, max., resistive load (τ = 0 ms), at 250 V AC 48 W max., inductive load (τ = 40 ms), at 24 V DC 33 W max., inductive load (τ = 40 ms), at 220 V DC |
Overvoltage category |
III
|
Mounting width |
22.5 mm
|
Suitable for |
Monitoring of magnetic switches
Monitoring of emergency-stop circuits If the sensor circuit is interrupted, the safety relay switches to safe mode Module used to safely interrupt electrical circuits Monitoring of optoelectronic protection equipment Safety relay for monitoring one or two-channel signal generators and control of actuators |
Relative humidity |
< 75 %
|
LED indicator |
Status indication of SmartWire-DT network: Green LED
|
Pick-up time |
< 100 ms typ. (at Uₑ in manual mode)
< 150 ms typ. (at Uₑ in automatic mode) |
Input |
∞ ms, Simultaneity for inputs 1/2
|
Model |
Basic device
|
Safety type (IEC 61496-1) |
None
|
Safety parameter (EN ISO 13849-1) |
Cat. 4, Category
PL e, Performance level |
Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
Rated control supply voltage (Us) at DC - max |
230 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated insulation voltage (Ui) |
250 V
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Release-delay - max |
0 s
|
Release-delay - min |
0 s
|
Static heat dissipation, non-current-dependent Pvs |
2.9 W
|
Product category |
Electronic safety relays
|
SIL (IEC 61508) |
3
|
Prooftest |
56 Months (Low Demand)
240 Months (High Demand) |
Quadratic summation current |
72 A² (ITH² = I1² + I2² + In²)
|
Rated operational voltage |
230 V AC
|
Reset time |
Normally < 20 ms (when driven via the sensor circuits)
|
Safety parameter (IEC 62061) |
Cat. 4, Category
SIL 3, Safety integrity level, In accordance with IEC 61508 10 x 10-10, PFHd, Probability of failure per hour SILCL 3, Safety integrity level claim limit SIL 3, Safety integrity level |
Uninterrupted current |
6 A N/O, Limiting continuous current
|
Short-circuit protection |
6 A gL/gG, For output circuits, External
|
Stop category (IEC 60204) |
0
|
Switching capacity |
0.05 W
5 A, DC-13 at 24 V, Outputs |
Switching frequency |
Max. 1 Hz, Input data
|
Power consumption |
2.9 W
|
Control voltage 1 - min |
24 V
|
Control voltage 1 - max |
230 V
|
Control voltage 2 - min |
24 V
|
Control voltage 2 - max |
230 V
|
Control voltage 1 type |
AC/DC
|
Control voltage 2 type |
AC/DC
|
Voltage type of supply voltage |
AC/DC
|
Voltage type of operating voltage |
AC/DC
|
Rated switch current |
5 A
|
Supply voltage at AC, 50 Hz - min |
24 V
|
Supply voltage at AC, 50 Hz - max |
230 V
|
Supply voltage at AC, 60 Hz - min |
24 V
|
Supply voltage at AC, 60 Hz - max |
230 V
|
Supply voltage at DC - min |
24 V
|
Supply voltage at DC - max |
230 V
|
Operating voltage at AC, 50 Hz - min |
24 V
|
Operating voltage at AC, 50 Hz - max |
230 V
|
Operating voltage at AC, 60 Hz - min |
24 V
|
Operating voltage at AC, 60 Hz - max |
230 V
|
Operating voltage at DC - min |
24 V
|
Operating voltage at DC - max |
230 V
|