The Eaton 9395 UPSs provide industry-leading efficiency and scalable battery runtimes in a small footprint. Large data centers, healthcare applications, multi-tenant data centers, light industry, and other critical systems can lower their total cost of ownership. Monitor and manage your 9395 UPS with the color LCD touchscreen display.
Eaton Intelligent Power Manager
Eaton Network Card-MS
Eaton PredictPulse remote monitoring service
Eaton Environmental Monitoring Probe for UPS
Eaton Industrial Relay Card-MS
200-1200 kVA
480V standard; 400V optional and 600/575V optional
50/60 Hz
Up to 97% (480V) and 96% (600V and 400V) in double conversion
Up to 99% in Energy Saver System
4 UPS units maximum for distributed bypass and 8 UPS units maximum with SBM
Tower
Type: VRLA, AGM, wet cell, lithium-ion
Voltage: 480V
Charging method: ABM technology or float, selectable
| Model | Power Rating |
Voltage |
ESS Efficiency | Double Conversion Efficiency |
| Power Xpert 9395 | 225 to 1100 kVA | 480V and 400V | 99% | 94% |
| Power Xpert 9395 high performance 480V | 200 to 1200 kVA/kW |
480V | 99% | up to 97% |
| Power Xpert 9395 high performance 400/415V |
200 to 1100 kVA/kW | 400/415V | 99% | up to 96% |
| Power Xpert 9395 high performance 600/575V |
200 to 1100 kVA/kW | 600/575V | 99% | up to 96% |
225/205 250/228 275/250 450/410 500/450 550/501 650/592 750/683 825/751 1000/910 1100/1001
200/200 250/250 275/275 300/300 400/400 500/500 550/550 600/600 675/675 750/750 825/825 900/900 1000/1000 1100/1100 1200/1200
480V standard; 600/575V and 400/415V optional
+10% / -15% (400V, 415V, 480V, 600V)
+15%/ -15% (400V)
+15%/ -10% (380V)
45–65 Hz
<3% (no input filter required)
480V standard; 600/575V and 400/415V optional
PWM with IGBT Switching
Up to a .9 power factor leading without derating
110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds
52.8”w x 34.4”d x 73.9”h
1900 lb
73.6”w x 34.4”d x 73.9”h
3150 lb
73.6”w x 34.4”d x 73.9”h
3274 lb
102.9”w x 34.4”d x 73.9”h
4654 lb
29.3”w x 34.4”d x 73.9”h
1380 lb
140.3"w x 34.4"d x 73.9"h
5550 lb
169.6"w x 34.4"d x 73.9"h
6930 lb
169.6"w x 34.4"d x 73.9"h
7050 lb
52.5”w x 34.4”d x 74”h
2150 lb (975 kg)
1886 lb (857 kg)
73.8”w x 34.4”d x 74”h
3184 lb (1447 kg)
N/A
29”w x 34.4”d x 74”h
1037 lb (470 kg)
1047 lb (475 kg)
73.8”w x 34.4”d x 74”h
3184 lb (1447 kg)
3184 lb (1447 kg)
103”w x 34.4”d x 74”h
4221 lb (1918 kg)
N/A
141”w x 34.4d x 74”h
5236 lb (2375 kg)
5236 lb (2375 kg)
170.1w x 34.4d x 74”h
6523 lb (2959 kg)
N/A
170.1w x 34.4d x 74”h
6523 lb (2959 kg)
6620 lb (3003 kg)
102.9”w x 34.4”d x 74”h
4354 lb (1975 kg)
126.2”w x 34.4”d x 74”h
5683 lb (2578 kg)
126.2”w x 34.4”d x 74”h
5683 lb (2378 kg)
29”w x 34.4”d x 74”h
1037 lb (471 kg)
126.2”w x 34.4”d x 74”h
5683 lb (2578 kg)
155.2”w x 34.4”d x 74”h
6722 lb (3049 kg)
195”w x 34.4”d x 74”h
10050 lb (4559 kg)
224”w x 34.4”d x 74”h
11550 lb (5239 kg)
224”w x 34.4”d x 74”h
11550 lb (5239 kg)
29”w x 34.4”d x 74”h
1037 lb (470 kg)
UL 1778, cUL
IEC 62040-2, C3 limits
PXGX-UPS card (included with PredictPulse activation)
ModBus RTU card
AS/400 Relay card
Industrial Relay card
HotSync CAN Bridge card
Environmental Monitoring Probe (included)
Eaton’s Intelligent Power Manager software enables you to: