NZMN2-MX140-NA. NZM2 PXR20 circuit breaker, 140A, 3p, Screw terminal, UL/CSA
| Product Name |
Eaton Moeller series NZM molded case circuit breaker electronic
|
| Catalog Number |
192524
|
| EAN |
4015081932528
|
| Product Length/Depth |
149 mm
|
| Product Height |
195 mm
|
| Product Width |
105 mm
|
| Product Weight |
2.345 kg
|
| Compliances |
RoHS conform
|
| Certifications |
UL508
IEC 60947-2 IEC UL listed CSA-C22.2 No. 5-09 UL (Category Control Number DIVQ) CSA (File No. 22086) UL (File No. E31593) CSA certified UL 489 UL/CSA Specially designed for North America CE marking CSA (Class No. 1432-01) |
| Model Code |
NZMN2-MX140-NA
|
| Application |
Branch circuits, feeder circuits
|
| Type |
Circuit breaker
|
| Circuit breaker frame type |
NZM2
|
| Number of poles |
Three-pole
|
| Release system |
Electronic release
|
| Special features |
|
| Fitted with: |
Thermal protection
|
| Rated operating power at AC-3, 230 V |
45 kW
|
| Rated operating power at AC-3, 400 V |
75 kW
|
| Amperage Rating |
140 A
|
| Instantaneous current setting (Ii) - min |
280 A
|
| Instantaneous current setting (Ii) - max |
2520 A
|
| Overload current setting (Ir) - min |
56 A
|
| Overload current setting (Ir) - max |
140 A
|
| Short-circuit release non-delayed setting - min |
280 A
|
| Short-circuit release non-delayed setting - max |
2520 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
150 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
150 kA
|
| Rated operating power at AC-3, 230 V |
45 kW
|
| Rated operating power at AC-3, 400 V |
75 kW
|
| Electrical connection type of main circuit |
Screw connection
|
| Handle type |
Rocker lever
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Direction of incoming supply |
As required
|
| Voltage rating |
690 V - 690 V
|
| Rated operating voltage Ue (UL) - max |
480 V
|
| Rated insulation voltage (Ui) |
690 V
|
| Amperage Rating |
140 A
|
| Instantaneous current setting (Ii) - min |
280 A
|
| Instantaneous current setting (Ii) - max |
2520 A
|
| Overload current setting (Ir) - min |
56 A
|
| Overload current setting (Ir) - max |
140 A
|
| Short-circuit release non-delayed setting - min |
280 A
|
| Short-circuit release non-delayed setting - max |
2520 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
150 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
150 kA
|
| Rated operating power at AC-3, 230 V |
45 kW
|
| Rated operating power at AC-3, 400 V |
75 kW
|
| Electrical connection type of main circuit |
Screw connection
|
| Handle type |
Rocker lever
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Direction of incoming supply |
As required
|
| Mounting Method |
Built-in device fixed built-in technique
Fixed |
| Degree of protection |
IP20
|
| Switch off technique |
Electronic
|