Billedet er repræsentativt
Download
Eaton Moeller series NZM Undervoltage release, 380-440VAC, +2early N/O, for NZM1, 20L
Product Name |
Eaton Moeller series NZM Undervoltage release
|
Catalog Number |
259624
|
EAN |
4015082596248
|
Product Length/Depth |
37 mm
|
Product Height |
66 mm
|
Product Width |
32 mm
|
Product Weight |
0.056 kg
|
Compliances |
UL/CSA
IEC RoHS conform |
Certifications |
IEC60947
CSA-C22.2 No. 5-09 UL489 CSA (Class No. 1437-01) UL (File No. E140305) UL (Category Control Number DIHS) CSA certified UL listed CSA (File No. 22086) CE marking |
Model Code |
NZM1-XUHIV20L380-440AC
|
Type |
|
Special features |
|
Frame |
NZM1
|
Fitted with: |
Two separate early-make auxiliary contacts
|
Suitable for |
Off-load switch
|
Used with |
NZM1(-4), N(S)1(-4)
|
Rated control supply voltage |
380 - 440 V 50/60 Hz
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
380 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
440 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
380 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
440 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Voltage tolerance - min |
0.85
|
Voltage tolerance - max |
1.1
|
Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
Power consumption |
0.8 W (sealing DC)
1.5 VA (sealing AC) |
Pick-up power consumption at AC (undervoltage release) |
1.5 VA
|
Pick-up power consumption at DC (undervoltage release) |
0.8 W
|
Reaction time |
19 ms
|
Minimum command time - min |
10 ms
|
Minimum command time - max |
15 ms
|
Electric connection type |
Screw connection
|
Voltage type |
AC
|
Rated control voltage (relay contacts) |
380 V AC
440 V AC |
Rated control supply voltage |
380 - 440 V 50/60 Hz
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
380 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
440 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
380 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
440 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Voltage tolerance - min |
0.85
|
Voltage tolerance - max |
1.1
|
Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
Power consumption |
0.8 W (sealing DC)
1.5 VA (sealing AC) |
Pick-up power consumption at AC (undervoltage release) |
1.5 VA
|
Pick-up power consumption at DC (undervoltage release) |
0.8 W
|
Reaction time |
19 ms
|
Minimum command time - min |
10 ms
|
Minimum command time - max |
15 ms
|
Electric connection type |
Screw connection
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
2
|
Connection type |
With 3 m connection cable instead of screw termination
|