Billedet er repræsentativt
Download
Eaton Moeller series NZM Shunt release, 24VAC/DC, +1early N/O, for NZM4
| Product Name |
Eaton Moeller series NZM Shunt release
|
| Catalog Number |
266471
|
| EAN |
4015082664718
|
| Product Length/Depth |
107 mm
|
| Product Height |
51 mm
|
| Product Width |
64 mm
|
| Product Weight |
0.24 kg
|
| Compliances |
UL/CSA
IEC RoHS conform |
| Certifications |
UL489
UL (File No. E140305) UL (Category Control Number DIHS) CE marking CSA certified CSA (Class No. 1437-01) CSA (File No. 22086) UL listed IEC60947 CSA-C22.2 No. 5-09 |
| Model Code |
NZM4-XAHIV24AC/DC
|
| Type |
|
| Special features |
|
| Frame |
NZM4
|
| Fitted with: |
Early-make auxiliary contact
|
| Suitable for |
Off-load switch
|
| Used with |
NZM4(-4), N(S)4(-4)
|
| Rated control supply voltage |
24 V AC/DC
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
24 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
24 V
|
| Rated control supply voltage (Us) at DC - min |
24 V
|
| Rated control supply voltage (Us) at DC - max |
24 V
|
| Frequency rating |
50 Hz / 60 Hz / 200 Hz / 400 Hz, DC (shunt release)
|
| Pick-up power consumption (shunt release) |
2.5 VA/W
|
| Reaction time |
22 ms
|
| Minimum command time - min |
10 ms
|
| Minimum command time - max |
15 ms
|
| Electric connection type |
Screw connection
|
| Voltage type |
AC
|
| Voltage rating |
0.7 - 1.1 x Us
|
| Voltage rating at AC (x Us) - min |
0.7
|
| Voltage rating at AC (x Us) - max |
1.1
|
| Rated control voltage (relay contacts) |
24 V AC
24 V DC |
| Rated control supply voltage |
24 V AC/DC
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
24 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
24 V
|
| Rated control supply voltage (Us) at DC - min |
24 V
|
| Rated control supply voltage (Us) at DC - max |
24 V
|
| Frequency rating |
50 Hz / 60 Hz / 200 Hz / 400 Hz, DC (shunt release)
|
| Pick-up power consumption (shunt release) |
2.5 VA/W
|
| Reaction time |
22 ms
|
| Minimum command time - min |
10 ms
|
| Minimum command time - max |
15 ms
|
| Electric connection type |
Screw connection
|
| Number of contacts (change-over contacts) |
0
|
| Number of contacts (normally closed contacts) |
0
|
| Number of contacts (normally open contacts) |
1
|
| Connection type |
With bolt connection
|