Download dokument () af 20

266685
Modelkode: NZM4-XR208-240AC

Eaton Moeller series NZM - Molded Case Circuit Breaker. Remote operator, 208-240VAC, for size 4

General specifications

Product Name
Eaton Moeller series NZM remote operator
Catalog Number
266685
EAN
4015082666859
Product Length/Depth
189 mm
Product Height
202 mm
Product Width
210 mm
Product Weight
6.1 kg
Compliances
IEC
UL/CSA
RoHS conform
Certifications
CSA certified
CSA (Class No. 1437-01)
UL listed
UL489
UL (File No. E140305)
UL (Category Control Number DIHS)
CE marking
IEC60947
CSA (File No. 22086)
CSA-C22.2 No. 5-09
Model Code
NZM4-XR208-240AC

Tekniske data – elektrisk

Type
  • Accessory
  • Remote operator, can be synchronized
Number of poles
Three-pole/Four-pole
Special features
  • Cannot be combined with switch-disconnector PN...
  • Do not install M22-CK11(20/02) dual auxiliary contacts in the right-hand side auxiliary contact slot in NZM4-XR
Frame
NZM4
Used with
N(S)4(-4)
NZM4(-4)

Tekniske data – elektrisk

Rated control supply voltage (Us) at AC, 50 Hz - min
208 V
Rated control supply voltage (Us) at AC, 50 Hz - max
240 V
Rated control supply voltage (Us) at AC, 60 Hz - min
208 V
Rated control supply voltage (Us) at AC, 60 Hz - max
240 V
Voltage tolerance - min
0.85
Voltage tolerance - max
1.1
Rated operating frequency
50 Hz
Power consumption
350 VA (110 - 130 V AC)
Closing delay
100 ms
Breaking time
3000 ms
Number of operations per hour - max
20
Signal duration of remote operator at switch off - min
500 ms
Signal duration of remote operator at switch on - min
30 ms

Tekniske data – kommunikation

Voltage type
AC
Voltage rating
208 - 240 V 50/60 Hz
Operating voltage - min
0.85 x Us
Operating voltage - max
1.1 x Us
Rated control supply voltage (Us) at AC, 50 Hz - min
208 V
Rated control supply voltage (Us) at AC, 50 Hz - max
240 V
Rated control supply voltage (Us) at AC, 60 Hz - min
208 V
Rated control supply voltage (Us) at AC, 60 Hz - max
240 V
Voltage tolerance - min
0.85
Voltage tolerance - max
1.1
Rated operating frequency
50 Hz
Power consumption
350 VA (110 - 130 V AC)
Closing delay
100 ms
Breaking time
3000 ms
Number of operations per hour - max
20
Signal duration of remote operator at switch off - min
500 ms
Signal duration of remote operator at switch on - min
30 ms

Tekniske data – mekanisk

Switch drive type
Motor drive
Lifespan, mechanical
10000 operations

Eksportér produktspecifikation

Bemærk: Hvis fil(er) mangler i .zip-download, understøttes filtypen ikke ved bulk download.